Removal of the Sense Line between the Bleed-Air Precooler Exchanger (Upstream) and the Bleed Differential Pressure-Transducer
TASK 36-11-49-000-826-A
Removal of the Sense Line between the Bleed-Air Precooler Exchanger (Upstream) and the Bleed Differential Pressure-Transducer
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 36-11-49-861-114-A ** ON A/C NOT FOR ALL
Subtask 36-11-49-020-146-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 12:38:01 UTC
Removal of the Sense Line between the Bleed-Air Precooler Exchanger (Upstream) and the Bleed Differential Pressure-Transducer
WARNING:
MAKE SURE THAT THE PNEUMATIC SYSTEM IS DEPRESSURIZED BEFORE YOU START WORK. PRESSURIZED AIR CAN CAUSE INJURY TO PERSONNEL.
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE AFTER SHUTDOWN. THE ENGINE CAN STAY HOT FOR A LONG TIME. IF YOU DO NOT OBEY THIS INSTRUCTION, INJURY CAN OCCUR.
WARNING:
ALWAYS USE APPLICABLE GLOVES TO TOUCH HOT PARTS. HOT PARTS CAN CAUSE INJURY TO PERSONS.
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
CAUTION:
BE VERY CAREFUL WHEN YOU DO WORK ON OR NEAR THE AIR-CONDITIONING DUCTS. THE DUCTS ARE MADE OF THIN MATERIAL AND YOU CAN EASILY BREAK THEM.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE |
| No specific | AR | PLUG - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 413 | UPPER FWD PYLON |
| 423 | UPPER FWD PYLON |
| FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1) | |
| 413AT, 413BT, 413CT, 413DT | |
| FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2) | |
| 423AT, 423BT, 423CT, 423DT | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 49-00-00-860-009-A | APU Shutdown by External Power (131-9(A)) |
| TASK 49-00-00-860-009-A-01 | APU Shutdown by Batteries (131-9(A)) |
| TASK 71-00-00-860-833-A | Procedure to Prevent Engine Motoring |
Subtask 36-11-49-861-114-A ** ON A/C NOT FOR ALL
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002) or (Ref. AMM TASK 24-41-00-861-002).
Subtask 36-11-49-941-133-A ** ON A/C NOT FOR ALL (Ref. AMM TASK 24-41-00-861-002) or (Ref. AMM TASK 24-41-00-861-002).
B. Safety Precautions
(1) Make sure that the engine 1(2) shutdown occurred not less than five minutes before you do this procedure.
(2) On AIR COND panel 30VU:
(a) Make sure that the ENG 1(2) BLEED pushbutton switch is released (OFF legend on).
(b) Make sure that the APU BLEED pushbutton switch is released (ON legend off).
(c) Put a WARNING NOTICE(S) in position to tell persons not to operate the pneumatic system.
(3) Do the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833).
(4) On the HP ground connector:
(a) Put a WARNING NOTICE(S) in position to tell persons not to pressurize the pneumatic system.
Subtask 36-11-49-865-198-A ** ON A/C NOT FOR ALL (1) Make sure that the engine 1(2) shutdown occurred not less than five minutes before you do this procedure.
(2) On AIR COND panel 30VU:
(a) Make sure that the ENG 1(2) BLEED pushbutton switch is released (OFF legend on).
(b) Make sure that the APU BLEED pushbutton switch is released (ON legend off).
(c) Put a WARNING NOTICE(S) in position to tell persons not to operate the pneumatic system.
(3) Do the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833).
(4) On the HP ground connector:
(a) Put a WARNING NOTICE(S) in position to tell persons not to pressurize the pneumatic system.
C. Open, safety and tag this(these) circuit breaker(s):
Subtask 36-11-49-010-233-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 4020KM1 (POWER PLANTDEMOUNTABLE, ENG 1) | |||
| 49VU | AIR BLEED/ENG 1/CTL | 2HA1 | D11 |
| 122VU | AIR BLEED/ENG 1/MONG | 3HA1 | Z23 |
| FOR FIN: 4020KM2 (POWER PLANTDEMOUNTABLE, ENG 2) | |||
| 49VU | AIR BLEED/ENG 2/MONG | 3HA2 | D12 |
| 122VU | AIR BLEED/ENG 2/CTL | 2HA2 | Z22 |
D. Get Access
(1) Put the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position at the pylon access panels.
(2) Remove these access panels:
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
413AT 413BT 413CT 413DT
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
423AT 423BT 423CT 423DT
4. Procedure(1) Put the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position at the pylon access panels.
(2) Remove these access panels:
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
413AT 413BT 413CT 413DT
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
423AT 423BT 423CT 423DT
Subtask 36-11-49-020-146-A ** ON A/C NOT FOR ALL
A. Removal of the Sense Line between the Bleed-Air Precooler Exchanger (Upstream) and the Bleed Differential Pressure-Transducer
(1) If you use the APU to energize the electrical circuits, stop the APU:
(a) Make sure that the pressure and the temperature of the bleed-air duct system are in ambient conditions.
(4) Disconnect the nut (4) of the sense line (1) from the port of the bleed differential pressure-transducer (3).
(5) Disconnect the nut (5) of the sense line (1) from the port of the bleed-air precooler (6).
(6) Remove the sense line (1).
(7) Put PLUG - BLANKING on the ports of the bleed-air precooler (6) and the bleed differential pressure-transducer (3).
(8) Put the PLUG-BLANKING in each disconnected line end.
(1) If you use the APU to energize the electrical circuits, stop the APU:
- For GTCP 36-300 APU (Ref. AMM D/O 49-00-00-86)
- For APS 3200 APU (Ref. AMM D/O 49-00-00-86)
- For 131-9(A) APU (Ref. AMM TASK 49-00-00-860-009).
(a) Make sure that the pressure and the temperature of the bleed-air duct system are in ambient conditions.
WARNING:
MAKE SURE THAT THE PNEUMATIC SYSTEM IS DEPRESSURIZED BEFORE YOU START WORK. PRESSURIZED AIR CAN CAUSE INJURY TO PERSONNEL.
WARNING:
DO NOT TOUCH THE UNIT UNTIL IT IS SUFFICIENTLY COOL TO PREVENT BURNS WHEN YOU DO THE MAINTENANCE TASK(S).
(3) Remove the two grommets (2) of the sense line (1). (4) Disconnect the nut (4) of the sense line (1) from the port of the bleed differential pressure-transducer (3).
(5) Disconnect the nut (5) of the sense line (1) from the port of the bleed-air precooler (6).
(6) Remove the sense line (1).
(7) Put PLUG - BLANKING on the ports of the bleed-air precooler (6) and the bleed differential pressure-transducer (3).
(8) Put the PLUG-BLANKING in each disconnected line end.
Sense Line between the Bleed-Air Precooler Exchanger (Upstream) and the Bleed Differential Pressure-Transducer