Removal of the Starter Valve Elbow-Duct and the Precooler Exchanger Tee-Duct in the Pylon
TASK 36-11-49-000-015-A
Removal of the Starter Valve Elbow-Duct and the Precooler Exchanger Tee-Duct in the Pylon
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 36-11-49-861-087-A ** ON A/C NOT FOR ALL
Subtask 36-11-49-020-108-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 01:11:08 UTC
Removal of the Starter Valve Elbow-Duct and the Precooler Exchanger Tee-Duct in the Pylon
WARNING:
MAKE SURE THAT THE PNEUMATIC SYSTEM IS DEPRESSURIZED BEFORE YOU START WORK. PRESSURIZED AIR CAN CAUSE INJURY TO PERSONNEL.
CAUTION:
USE A SECOND WRENCH TO APPLY COUNTER TORQUE TO THE UNION ON THE VALVE WHEN YOU CONNECT THE HP SENSE TUBE.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE |
| No specific | AR | PLUG - BLANKING |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 411AT, 413AL, 413AR, 413BL, 413BR, 421AT, 423AL, 423AR, 423BL, 423BR |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 49-00-00-860-009-A | APU Shutdown by External Power (131-9(A)) |
| TASK 49-00-00-860-009-A-01 | APU Shutdown by Batteries (131-9(A)) |
Subtask 36-11-49-861-087-A ** ON A/C NOT FOR ALL
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002) or (Ref. AMM TASK 24-41-00-861-002).
Subtask 36-11-49-941-107-A ** ON A/C NOT FOR ALL (Ref. AMM TASK 24-41-00-861-002) or (Ref. AMM TASK 24-41-00-861-002).
B. Safety Precautions
(1) Make sure that the engine 1 (2) shutdown occurred not less than 5 minutes before you do this procedure
(2) On the AIR COND control panel 30VU:
Subtask 36-11-49-010-158-B ** ON A/C NOT FOR ALL (1) Make sure that the engine 1 (2) shutdown occurred not less than 5 minutes before you do this procedure
(2) On the AIR COND control panel 30VU:
- Make sure that the ENG 1(2) BLEED pushbutton switch is released (the OFF legend is on).
- Make sure that the APU BLEED pushbutton switch is released (the ON legend is off).
- Put a WARNING NOTICE(S) in position to tell persons not to operate the pneumatic system.
- Put a WARNING NOTICE(S) in position to tell persons not to start the engine 1(2).
- Put a WARNING NOTICE(S) in position to tell persons not to pressurize the pneumatic system.
- make sure that the ON legend of the ENG/FADEC GND PWR 1(2) pushbutton switch is off
- put a WARNING NOTICE(S) in position to tell persons not to energize the FADEC 1(2).
C. Get Access
(1) Put the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position below the engine.
(2) Remove the access panels:
4. Procedure(1) Put the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position below the engine.
(2) Remove the access panels:
Subtask 36-11-49-020-108-A ** ON A/C NOT FOR ALL
A. Removal of the Starter Valve Elbow-Duct and the Precooler Exchanger Tee-Duct in the Pylon
(1) If you use the APU to energize the electrical circuits, stop the APU:
(a) Make sure that the pressure and the temperature of the bleed-air duct system are in ambient conditions.
(a) Remove the screws (6) and the washers (7) from the support (8).
(b) Remove the clamps (9) and (12) to disengage the duct (10).
(c) Remove and discard the seal (11) and the support (8).
(d) Remove the duct (10).
(4) Remove the precooler exchanger tee-duct as follows:
(a) Remove the screws (3) and the washers (2) from the tee-duct (1).
(b) Remove the clamps (4) and (5).
(c) Disengage the tee-duct (1).
(d) Remove the tee-duct (1).
(e) Put the PLUG-BLANKING in each disconnected line end.
(1) If you use the APU to energize the electrical circuits, stop the APU:
- For GTCP 36-300 APU (Ref. AMM D/O 49-00-00-86)
- For APS 3200 APU (Ref. AMM D/O 49-00-00-86)
- For 131-9(A) APU (Ref. AMM TASK 49-00-00-860-009).
(a) Make sure that the pressure and the temperature of the bleed-air duct system are in ambient conditions.
WARNING:
MAKE SURE THAT THE PNEUMATIC SYSTEM IS DEPRESSURIZED BEFORE YOU START WORK. PRESSURIZED AIR CAN CAUSE INJURY TO PERSONNEL.
WARNING:
DO NOT TOUCH THE UNIT UNTIL IT IS SUFFICIENTLY COOL TO PREVENT BURNS WHEN YOU DO THE MAINTENANCE TASK(S).
(3) Remove the starter valve elbow-duct as follows:(a) Remove the screws (6) and the washers (7) from the support (8).
(b) Remove the clamps (9) and (12) to disengage the duct (10).
(c) Remove and discard the seal (11) and the support (8).
(d) Remove the duct (10).
(4) Remove the precooler exchanger tee-duct as follows:
(a) Remove the screws (3) and the washers (2) from the tee-duct (1).
(b) Remove the clamps (4) and (5).
(c) Disengage the tee-duct (1).
(d) Remove the tee-duct (1).
(e) Put the PLUG-BLANKING in each disconnected line end.
Starter Valve Elbow-Duct and Precooler Exchanger Tee-Duct in the Pylon