W DOC AIRBUS | AMM A320F

Remove Portable Oxygen Cylinder Assembly for in Shop Hydrostatic Test and Functional Check of Regulator Valve Assembly


TASK 35-32-42-750-001-A
Remove Portable Oxygen Cylinder Assembly for in Shop Hydrostatic Test and Functional Check of Regulator Valve Assembly


WARNING: KEEP ALL HYDROCARBONS (FUELS, LUBRICANTS, ETC.) AWAY FROM ALL SOURCE OF OXYGEN. OXYGEN BECOMES EXPLOSIVE WHEN IT TOUCHES HYDROCARBONS.
WARNING: CLEAN THE TOOLS AND MAKE SURE YOUR HANDS ARE CLEAN TO PREVENT CONTAMINATION OF THE OXYGEN SYSTEM.
WARNING: MAKE SURE THAT YOU OBEY THE MANUFACTURER'S INSTRUCTIONS AND NATIONAL HAZARDOUS MATERIAL REGULATIONS WHEN YOU MOVE OR KEEP THIS EQUIPMENT IN STORAGE:
  • CHEMICAL OXYGEN GENERATORS
  • PROTECTIVE BREATHING EQUIPMENT
  • FIXED AND PORTABLE OXYGEN CYLINDERS.
SPECIAL PRECAUTIONS ARE NECESSARY FOR THIS EQUIPMENT.
ZONE: 200
1. Reason for the Job
Refer to the MPD TASK: 353000-02
REMOVE PORTABLE OXYGEN CYLINDER ASSEMBLY FOR IN SHOP HYDROSTATIC TEST AND FUNCTIONAL CHECK OF REGULATOR VALVE ASSEMBLY.
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
200
UPPER HALF FUSELAGE
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
TASK 35-00-00-860-001-A
Special Precautions When Working on a Gaseous Oxygen System
TASK 35-32-42-000-001-A
Removal of the Portable Oxygen Cylinder
TASK 35-32-42-400-001-A
Installation of the Portable Oxygen Cylinder
3. Job Set-up
Subtask 35-32-42-860-060-A
A. Aircraft Maintenance Configuration
   (1) Obey the special precautions when you do work on a gaseous oxygen system (Ref. AMM TASK 35-00-00-860-001).
   (2) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 35-32-42-010-060-A
B. Get Access
   (1) Remove the portable oxygen cylinder (Ref. AMM TASK 35-32-42-000-001).
4. Procedure
Subtask 35-32-42-750-053-A
A. Test of the Portable Oxygen Cylinder(s)
   (1) Send the portable oxygen cylinder(s) to the workshop:
     (a) For the functional test of regulator valve assembly.
     (b) For the hydrostatic test of the portable oxygen cylinder(s).
5. Close-up
Subtask 35-32-42-410-056-A
A. Close Access
   (1) Install a serviceable portable oxygen cylinder (Ref. AMM TASK 35-32-42-400-001).
   (2) Make sure that the work area is clean and clear of tools and other items.
Subtask 35-32-42-860-061-A
B. Put the aircraft back to its initial configuration.
   (1) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
[Rev.10 from 2021] 2026.04.01 01:05:37 UTC