Remove Portable Oxygen Cylinder Assembly for in Shop Hydrostatic Test and Functional Check of Regulator Valve Assembly
TASK 35-32-42-750-001-A
Remove Portable Oxygen Cylinder Assembly for in Shop Hydrostatic Test and Functional Check of Regulator Valve Assembly
Refer to the MPD TASK: 353000-02
REMOVE PORTABLE OXYGEN CYLINDER ASSEMBLY FOR IN SHOP HYDROSTATIC TEST AND FUNCTIONAL CHECK OF REGULATOR VALVE ASSEMBLY.
2. Job Set-up Information
A. Work Zones and Access Panels
B. Referenced Information
3. Job Set-up
Subtask 35-32-42-860-060-A
Subtask 35-32-42-750-053-A
Subtask 35-32-42-410-056-A
[Rev.10 from 2021]
2026.04.01 01:05:37 UTC
Remove Portable Oxygen Cylinder Assembly for in Shop Hydrostatic Test and Functional Check of Regulator Valve Assembly
WARNING:
KEEP ALL HYDROCARBONS (FUELS, LUBRICANTS, ETC.) AWAY FROM ALL SOURCE OF OXYGEN. OXYGEN BECOMES EXPLOSIVE WHEN IT TOUCHES HYDROCARBONS.
WARNING:
CLEAN THE TOOLS AND MAKE SURE YOUR HANDS ARE CLEAN TO PREVENT CONTAMINATION OF THE OXYGEN SYSTEM.
WARNING:
MAKE SURE THAT YOU OBEY THE MANUFACTURER'S INSTRUCTIONS AND NATIONAL HAZARDOUS MATERIAL REGULATIONS WHEN YOU MOVE OR KEEP THIS EQUIPMENT IN STORAGE:
- CHEMICAL OXYGEN GENERATORS
- PROTECTIVE BREATHING EQUIPMENT
- FIXED AND PORTABLE OXYGEN CYLINDERS.
ZONE: 200
1. Reason for the JobRefer to the MPD TASK: 353000-02
REMOVE PORTABLE OXYGEN CYLINDER ASSEMBLY FOR IN SHOP HYDROSTATIC TEST AND FUNCTIONAL CHECK OF REGULATOR VALVE ASSEMBLY.
2. Job Set-up Information
A. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 200 | UPPER HALF FUSELAGE |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
| TASK 35-00-00-860-001-A | Special Precautions When Working on a Gaseous Oxygen System |
| TASK 35-32-42-000-001-A | Removal of the Portable Oxygen Cylinder |
| TASK 35-32-42-400-001-A | Installation of the Portable Oxygen Cylinder |
Subtask 35-32-42-860-060-A
A. Aircraft Maintenance Configuration
(1) Obey the special precautions when you do work on a gaseous oxygen system (Ref. AMM TASK 35-00-00-860-001).
(2) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 35-32-42-010-060-A 4. Procedure(1) Obey the special precautions when you do work on a gaseous oxygen system (Ref. AMM TASK 35-00-00-860-001).
(2) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 35-32-42-750-053-A
A. Test of the Portable Oxygen Cylinder(s)
(1) Send the portable oxygen cylinder(s) to the workshop:
(a) For the functional test of regulator valve assembly.
(b) For the hydrostatic test of the portable oxygen cylinder(s).
5. Close-up(1) Send the portable oxygen cylinder(s) to the workshop:
(a) For the functional test of regulator valve assembly.
(b) For the hydrostatic test of the portable oxygen cylinder(s).
Subtask 35-32-42-410-056-A
A. Close Access
(1) Install a serviceable portable oxygen cylinder (Ref. AMM TASK 35-32-42-400-001).
(2) Make sure that the work area is clean and clear of tools and other items.
Subtask 35-32-42-860-061-A (1) Install a serviceable portable oxygen cylinder (Ref. AMM TASK 35-32-42-400-001).
(2) Make sure that the work area is clean and clear of tools and other items.
B. Put the aircraft back to its initial configuration.
(1) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
(1) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).