Installation of the Altitude Switch
TASK 35-23-15-400-001-A
Installation of the Altitude Switch
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 35-23-15-860-050-A
Subtask 35-23-15-420-050-A
Subtask 35-23-15-410-051-A
[Rev.10 from 2021]
2026.04.01 01:05:18 UTC
Installation of the Altitude Switch
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) |
| No specific | AR | CAP - BLANKING |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 211 | COCKPIT |
| 824 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 35-23-00-720-002-A | Functional Test of the Passenger Emergency-Oxygen System |
| TASK 52-41-00-010-002-A | Open the Avionics Compartment Doors for Access |
| TASK 52-41-00-410-002-A | Close the Avionics Compartment Doors after Access |
Subtask 35-23-15-860-050-A
A. Aircraft Maintenance Configuration
(1) Make sure that the ACCESS PLATFORM 2M (6 FT) is in position at the access door 824.
(2) Make sure that the access door 824 is open (Ref. AMM TASK 52-41-00-010-002).
Subtask 35-23-15-865-051-A (1) Make sure that the ACCESS PLATFORM 2M (6 FT) is in position at the access door 824.
(2) Make sure that the access door 824 is open (Ref. AMM TASK 52-41-00-010-002).
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | OXYGEN/PASSENGER/CTL AND WARN | 1WR | HA02 |
Subtask 35-23-15-420-050-A
A. Install the Altitude Switch
(1) Install the altitude switch (2) on its support (3) and install and tighten the screws (4) and the washers (5).
(2) Remove the CAP - BLANKING from the electrical connector (1).
(3) Connect the electrical connector (1) to the altitude switch (2).
(4) Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
1WR
Subtask 35-23-15-720-051-A (1) Install the altitude switch (2) on its support (3) and install and tighten the screws (4) and the washers (5).
(2) Remove the CAP - BLANKING from the electrical connector (1).
(3) Connect the electrical connector (1) to the altitude switch (2).
(4) Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
1WR
B. Functional test
(1) Do the functional test of the passenger oxygen system (Ref. AMM TASK 35-23-00-720-002).
5. Close-up(1) Do the functional test of the passenger oxygen system (Ref. AMM TASK 35-23-00-720-002).
Subtask 35-23-15-410-051-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 824 (Ref. AMM TASK 52-41-00-410-002).
(3) Remove the access platform(s).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 824 (Ref. AMM TASK 52-41-00-410-002).
(3) Remove the access platform(s).
Altitude Switch