Removal of the Emergency Oxygen Generators
TASK 35-21-42-000-001-A
Removal of the Emergency Oxygen Generators
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Expendable Parts
E. Referenced Information
3. Job Set-up
Subtask 35-21-42-860-051-A
Subtask 35-21-42-020-051-H ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 01:04:56 UTC
Removal of the Emergency Oxygen Generators
WARNING:
MAKE SURE THAT YOU OBEY THE MANUFACTURER'S INSTRUCTIONS AND NATIONAL HAZARDOUS MATERIAL REGULATIONS WHEN YOU MOVE OR KEEP THIS EQUIPMENT IN STORAGE:
- CHEMICAL OXYGEN GENERATORS
- PROTECTIVE BREATHING EQUIPMENT
- FIXED AND PORTABLE OXYGEN CYLINDERS.
WARNING:
CLEAN THE TOOLS AND MAKE SURE YOUR HANDS ARE CLEAN TO PREVENT CONTAMINATION OF THE OXYGEN SYSTEM.
WARNING:
KEEP ALL HYDROCARBONS (FUELS, LUBRICANTS, ETC.) AWAY FROM ALL SOURCE OF OXYGEN. OXYGEN BECOMES EXPLOSIVE WHEN IT TOUCHES HYDROCARBONS.
WARNING:
SUPPORT THE UNIT/ASSEMBLY. THE UNIT/ASSEMBLY IS HEAVY. IF YOU DO NOT SUPPORT IT, IT WILL FALL. THIS CAN CAUSE INJURY TO PERSONS, AND/OR DAMAGE TO EQUIPMENT.
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
CAUTION:
PUT DRY AND CLEAN METAL OR PLASTIC PLUGS ON ALL PIPES OR UNITS THAT YOU REMOVE TEMPORARILY. THEN PUT EACH PIPE OR UNIT IN A SEALED VINYL BAG. IF YOU DO NOT OBEY THESE INSTRUCTIONS, CONTAMINATION OF THE OXYGEN SYSTEM CAN OCCUR.
ZONE: 200
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 2 | GLOVES - COTTON, LINT-FREE, CLEAN |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| 995000-00 | 1 | TOOL-MANUAL RELEASE |
| 995022 | 2 | INSERTION TOOL-PIN,OXYGEN GENERATOR |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 200 | UPPER HALF FUSELAGE |
| FIG.ITEM | DESIGNATION | IPC-CSN |
|---|---|---|
| 9 | SAFETY RING WITH THE WARNING FLAG | AIPC 35-21-41-99-010 |
| 12 | SAFETY PIN WITH THE WARNING FLAG | AIPC 35-21-41-99-020 |
| 9 | SAFETY RING PIN WITH THE WARNING FLAG | AIPC 35-21-41-99-020 |
| 9 | SAFETY PIN WITH THE WARNING FLAG | AIPC 35-21-89-99-020 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 35-00-00-860-001-A | Special Precautions When Working on a Gaseous Oxygen System |
| TASK 35-21-41-000-001-A | Removal of the Emergency Oxygen Containers |
| TASK 35-21-43-000-001-A | Removal of the Oxygen Mask |
Subtask 35-21-42-860-051-A
A. Aircraft Maintenance Configuration
(1) Obey the special precautions when you work on a gaseous oxygen system (Ref. AMM TASK 35-00-00-860-001).
(2) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(3) In the cockpit, on the OXYGEN section of overhead panel 21VU:
(a) Put a WARNING NOTICE(S) in position to tell persons not to operate the emergency oxygen system.
Subtask 35-21-42-865-052-A (1) Obey the special precautions when you work on a gaseous oxygen system (Ref. AMM TASK 35-00-00-860-001).
(2) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(3) In the cockpit, on the OXYGEN section of overhead panel 21VU:
(a) Put a WARNING NOTICE(S) in position to tell persons not to operate the emergency oxygen system.
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 35-21-42-010-051-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | OXYGEN/PASSENGER/ACTUATION | 7WR | HA08 |
| 49VU | OXYGEN/PASSENGER/ACTUATION | 6WR | HA07 |
| 49VU | OXYGEN/PASSENGER/ACTUATION | 5WR | HA06 |
| 49VU | OXYGEN/PASSENGER/ACTUATION | 4WR | HA05 |
C. Get Access
(1) Remove the Emergency Oxygen Container (EOC) (Ref. AMM TASK 35-21-41-000-001).
(2) Put EOC on flat surface with clean and soft Textile-Lint free Cotton - (Material No.14SBA1) .
(3) Put the 995000-00 TOOL-MANUAL RELEASE into the access hole of EOC and open door of EOC.
4. Procedure(1) Remove the Emergency Oxygen Container (EOC) (Ref. AMM TASK 35-21-41-000-001).
(2) Put EOC on flat surface with clean and soft Textile-Lint free Cotton - (Material No.14SBA1) .
(3) Put the 995000-00 TOOL-MANUAL RELEASE into the access hole of EOC and open door of EOC.
NOTE: It is permitted to use alternative tool P/N 995000.
Subtask 35-21-42-020-051-H ** ON A/C NOT FOR ALL
A. Removal of the Oxygen Generator Type I
(2) Loosen the screw (10).
(3) Pull and hold the generator mounting clamp (11) away from the oxygen generator (2) and carefully remove the oxygen generator (2).
(4) Install the AIPC 35-21-41-99-020 SAFETY PIN WITH THE WARNING FLAG (12):
(a) Carefully put the 995022 INSERTION TOOL-PIN,OXYGEN GENERATOR between the firing pin housing (15) and the release pin (13).
(b) The firing pin (18) comes out.
(d) Hold the tool 995022 INSERTION TOOL-PIN,OXYGEN GENERATOR in position and put the AIPC 35-21-41-99-020 SAFETY PIN WITH THE WARNING FLAG (12) into the mounting hole.
(e) Remove the tool 995022 INSERTION TOOL-PIN,OXYGEN GENERATOR.
(f) Make sure that the waved part of the safety pin with the warning flag (12) points away from the eyelet of the release pin (13).
(5) If installed, disconnect the pull flags (19) from the snap hooks (6) of the masks (5).
(6) Pull the release pin (13) from the firing pin (18).
(a) Remove the release pin (13) together with the mask lanyards (7).
(7) Remove the mask supply hoses (4) from outlets of the outlet manifold (3) (Ref. AMM TASK 35-21-43-000-001).
(8) If necessary, discard the oxygen generator (2).
Subtask 35-21-42-020-051-I ** ON A/C NOT FOR ALL CAUTION:
BEFORE YOU MOVE AN OXYGEN GENERATOR (WITH OR WITHOUT AN OXYGEN CONTAINER), INSTALL A SAFETY RING OR PIN AND WARNING FLAG ON ITS IGNITION ACTUATOR. YOU MUST DO THIS:
- BEFORE YOU MOVE IT TO A DIFFERENT LOCATION
- BEFORE YOU PUT IT INTO STORAGE
- BEFORE YOU PREPARE IT FOR TRANSPORT.
CAUTION:
DO NOT PULL THE MASK LANYARD FROM THE END WITH THE RELEASE PIN. IF YOU PULL ON THIS END OF THE LANYARD, YOU WILL REMOVE THE RELEASE PIN AND START A FLOW OF OXYGEN WHICH CANNOT BE STOPPED.
(1) Disconnect the lanyards (7) from the snap hooks (6) of the masks (5). (2) Loosen the screw (10).
(3) Pull and hold the generator mounting clamp (11) away from the oxygen generator (2) and carefully remove the oxygen generator (2).
(4) Install the AIPC 35-21-41-99-020 SAFETY PIN WITH THE WARNING FLAG (12):
(a) Carefully put the 995022 INSERTION TOOL-PIN,OXYGEN GENERATOR between the firing pin housing (15) and the release pin (13).
(b) The firing pin (18) comes out.
NOTE: You can see the mounting hole for the safety pin with the warning flag.
(c) Make sure that the rubber pad face of the INSERTION TOOL points to the firing pin housing (15). (d) Hold the tool 995022 INSERTION TOOL-PIN,OXYGEN GENERATOR in position and put the AIPC 35-21-41-99-020 SAFETY PIN WITH THE WARNING FLAG (12) into the mounting hole.
(e) Remove the tool 995022 INSERTION TOOL-PIN,OXYGEN GENERATOR.
(f) Make sure that the waved part of the safety pin with the warning flag (12) points away from the eyelet of the release pin (13).
(5) If installed, disconnect the pull flags (19) from the snap hooks (6) of the masks (5).
(6) Pull the release pin (13) from the firing pin (18).
(a) Remove the release pin (13) together with the mask lanyards (7).
(7) Remove the mask supply hoses (4) from outlets of the outlet manifold (3) (Ref. AMM TASK 35-21-43-000-001).
(8) If necessary, discard the oxygen generator (2).
NOTE: If you have an oxygen generator (2) that is made by Rockwell Collins, refer to the related Component Maintenance Manual (CMM) for the discard procedure. It is necessary to send the component operation results to the manufacturer.
A. Removal of the Oxygen Generator
Emergency Oxygen Generators - Removal/Installation ** ON A/C NOT FOR ALL
Emergency Oxygen Generators - Removal/Installation ** ON A/C NOT FOR ALL
(2) Loosen the screw (14) to open the clamp (6).
(3) Carefully lift the oxygen generator (7) out of the foam pad (11) and remove it from the emergency oxygen container (12).
(5) Installation of the AIPC 35-21-41-99-010 SAFETY RING WITH THE WARNING FLAG (9).
(a) Put the 995022 INSERTION TOOL-PIN,OXYGEN GENERATOR between the housing of the firing pin (15) and the release pin (10).
(b) The firing pin (15) comes out and you can see the mounting hole for the safety ring with the warning flag (9).
(c) Hold the tool 995022 INSERTION TOOL-PIN,OXYGEN GENERATOR in position and install the safety pin with a warning flag (9).
(6) Disconnect the lanyards (1) from the snap hooks (2) of the masks (3).
(7) For oxygen container type II:
(a) Disconnect the pull flags (13) from the snap hooks (2) of the masks (3).
(8) Remove the supply hoses (4) from outlets of the outlet manifold (5) (Ref. AMM TASK 35-21-43-000-001).
(9) If necessary, discard the oxygen generator (7).
Subtask 35-21-42-020-051-M ** ON A/C NOT FOR ALL
Emergency Oxygen Generators - Removal/Installation ** ON A/C NOT FOR ALL
Emergency Oxygen Generators - Removal/Installation ** ON A/C NOT FOR ALL CAUTION:
BEFORE YOU MOVE AN OXYGEN GENERATOR (WITH OR WITHOUT AN OXYGEN CONTAINER), INSTALL A SAFETY RING OR PIN AND WARNING FLAG ON ITS IGNITION ACTUATOR. YOU MUST DO THIS:
- BEFORE YOU MOVE IT TO A DIFFERENT LOCATION
- BEFORE YOU PUT IT INTO STORAGE
- BEFORE YOU PREPARE IT FOR TRANSPORT.
CAUTION:
DO NOT PULL THE MASK LANYARD FROM THE END WITH THE RELEASE PIN. IF YOU PULL ON THIS END OF THE LANYARD, YOU WILL REMOVE THE RELEASE PIN AND START A FLOW OF OXYGEN WHICH CANNOT BE STOPPED.
(1) During removal of the oxygen generator (7), do not remove the release pin (10) from the firing pin (15) of the oxygen generator (7). (2) Loosen the screw (14) to open the clamp (6).
(3) Carefully lift the oxygen generator (7) out of the foam pad (11) and remove it from the emergency oxygen container (12).
NOTE: The foam pad is attached to the inner surface of the emergency oxygen container.
(4) Do not remove the foam pad (11) from the emergency oxygen container (12). (5) Installation of the AIPC 35-21-41-99-010 SAFETY RING WITH THE WARNING FLAG (9).
(a) Put the 995022 INSERTION TOOL-PIN,OXYGEN GENERATOR between the housing of the firing pin (15) and the release pin (10).
(b) The firing pin (15) comes out and you can see the mounting hole for the safety ring with the warning flag (9).
(c) Hold the tool 995022 INSERTION TOOL-PIN,OXYGEN GENERATOR in position and install the safety pin with a warning flag (9).
(6) Disconnect the lanyards (1) from the snap hooks (2) of the masks (3).
(7) For oxygen container type II:
(a) Disconnect the pull flags (13) from the snap hooks (2) of the masks (3).
(8) Remove the supply hoses (4) from outlets of the outlet manifold (5) (Ref. AMM TASK 35-21-43-000-001).
(9) If necessary, discard the oxygen generator (7).
NOTE: If you have an oxygen generator (7) that is made by Rockwell Collins, refer to the related Component Maintenance Manual (CMM) for the discard procedure. It is necessary to send the component operation results to the manufacturer.
A. Removal of the Oxygen Generator from the Emergency Oxygen Container Type I
(2) Remove the oxygen generator (7):
(a) Loosen the screw (5) on the mounting clamp (6).
(b) Carefully remove the mask assemblies (3) from the emergency oxygen container (12).
(c) Carefully remove the oxygen generator (7) from the emergency oxygen container (12).
(3) Install the safety pin with the warning flag (9):
(a) Carefully put the 995022 INSERTION TOOL-PIN,OXYGEN GENERATOR between the housing of the firing pin (2) and the release pin (11).
(b) The firing pin (2) comes out.
(d) Hold the tool 995022 INSERTION TOOL-PIN,OXYGEN GENERATOR in position and put the AIPC 35-21-41-99-020 SAFETY RING PIN WITH THE WARNING FLAG (9) or AIPC 35-21-89-99-020 SAFETY PIN WITH THE WARNING FLAG (9) into the mounting hole.
(e) Remove the tool 995022 INSERTION TOOL-PIN,OXYGEN GENERATOR.
(f) Make sure that the waved part of the AIPC 35-21-41-99-020 SAFETY RING PIN WITH THE WARNING FLAG (9) or AIPC 35-21-89-99-020 SAFETY PIN WITH THE WARNING FLAG (9) points away from the eyelet of the release pin (11).
(4) Pull the lanyard (1) and remove the release pin (11) from the firing pin (2).
(5) Remove the supply hoses (4) from the outlet of the outlet manifold (13) (Ref. AMM TASK 35-21-43-000-001).
(6) If necessary, discard the oxygen generator (7).
Subtask 35-21-42-020-052-A ** ON A/C NOT FOR ALL CAUTION:
DO NOT PULL THE MASK LANYARD FROM THE END WITH THE RELEASE PIN. IF YOU PULL ON THIS END OF THE LANYARD, YOU WILL REMOVE THE RELEASE PIN AND START A FLOW OF OXYGEN WHICH CANNOT BE STOPPED.
CAUTION:
BEFORE YOU MOVE AN OXYGEN GENERATOR (WITH OR WITHOUT AN OXYGEN CONTAINER), INSTALL A SAFETY RING OR PIN AND WARNING FLAG ON ITS IGNITION ACTUATOR. YOU MUST DO THIS:
(1) Wear GLOVES - COTTON, LINT-FREE, CLEAN when you work on the oxygen system. - BEFORE YOU MOVE IT TO A DIFFERENT LOCATION
- BEFORE YOU PUT IT INTO STORAGE
- BEFORE YOU PREPARE IT FOR TRANSPORT.
(2) Remove the oxygen generator (7):
(a) Loosen the screw (5) on the mounting clamp (6).
(b) Carefully remove the mask assemblies (3) from the emergency oxygen container (12).
(c) Carefully remove the oxygen generator (7) from the emergency oxygen container (12).
(3) Install the safety pin with the warning flag (9):
(a) Carefully put the 995022 INSERTION TOOL-PIN,OXYGEN GENERATOR between the housing of the firing pin (2) and the release pin (11).
(b) The firing pin (2) comes out.
NOTE: You can see the mounting hole for the safety pin with the warning flag.
(c) Make sure that the rubber pad face of the 995022 INSERTION TOOL-PIN,OXYGEN GENERATOR points to the housing of the firing pin (2). (d) Hold the tool 995022 INSERTION TOOL-PIN,OXYGEN GENERATOR in position and put the AIPC 35-21-41-99-020 SAFETY RING PIN WITH THE WARNING FLAG (9) or AIPC 35-21-89-99-020 SAFETY PIN WITH THE WARNING FLAG (9) into the mounting hole.
(e) Remove the tool 995022 INSERTION TOOL-PIN,OXYGEN GENERATOR.
(f) Make sure that the waved part of the AIPC 35-21-41-99-020 SAFETY RING PIN WITH THE WARNING FLAG (9) or AIPC 35-21-89-99-020 SAFETY PIN WITH THE WARNING FLAG (9) points away from the eyelet of the release pin (11).
(4) Pull the lanyard (1) and remove the release pin (11) from the firing pin (2).
(5) Remove the supply hoses (4) from the outlet of the outlet manifold (13) (Ref. AMM TASK 35-21-43-000-001).
(6) If necessary, discard the oxygen generator (7).
NOTE: If you have an oxygen generator (7) that is made by Rockwell Collins, refer to the related Component Maintenance Manual (CMM) for the discard procedure. It is necessary to send the component operation results to the manufacturer.
B. Removal of the Oxygen Generator Type II
(2) Loosen the screw (4).
(3) Pull and hold the generator mounting clamp (2) away from the oxygen generator (3) and carefully remove the oxygen generator (3).
(4) Install the safety pin with the warning flag (12):
(a) Carefully put the 995022 INSERTION TOOL-PIN,OXYGEN GENERATOR between the firing pin housing (17) and the release pin (15).
(b) The firing pin (13) comes out.
(d) Hold the tool 995022 INSERTION TOOL-PIN,OXYGEN GENERATOR in position and put the AIPC 35-21-41-99-020 SAFETY PIN WITH THE WARNING FLAG (12) into the mounting hole.
(e) Remove the tool 995022 INSERTION TOOL-PIN,OXYGEN GENERATOR.
(f) Make sure that the waved part of the safety pin with the warning flag (12) points away from the eyelet of the release pin (15).
(5) Disconnect the pull flags (7) from the snap hooks (6) of the masks (8).
(6) Pull the release pin (15) from the firing pin (13).
(a) Remove the release pin (15) together with the mask lanyards (5).
(7) Remove the mask supply hoses (9) from outlets of the outlet manifold (11) (Ref. AMM TASK 35-21-43-000-001).
(8) If necessary, discard the oxygen generator (3).
Subtask 35-21-42-020-052-M ** ON A/C NOT FOR ALL CAUTION:
BEFORE YOU MOVE AN OXYGEN GENERATOR (WITH OR WITHOUT AN OXYGEN CONTAINER), INSTALL A SAFETY RING OR PIN AND WARNING FLAG ON ITS IGNITION ACTUATOR. YOU MUST DO THIS:
- BEFORE YOU MOVE IT TO A DIFFERENT LOCATION
- BEFORE YOU PUT IT INTO STORAGE
- BEFORE YOU PREPARE IT FOR TRANSPORT.
CAUTION:
DO NOT PULL THE MASK LANYARD FROM THE END WITH THE RELEASE PIN. IF YOU PULL ON THIS END OF THE LANYARD, YOU WILL REMOVE THE RELEASE PIN AND START A FLOW OF OXYGEN WHICH CANNOT BE STOPPED.
(1) Disconnect the mask lanyards (5) from the snap hooks (6) of the masks (8). (2) Loosen the screw (4).
(3) Pull and hold the generator mounting clamp (2) away from the oxygen generator (3) and carefully remove the oxygen generator (3).
(4) Install the safety pin with the warning flag (12):
(a) Carefully put the 995022 INSERTION TOOL-PIN,OXYGEN GENERATOR between the firing pin housing (17) and the release pin (15).
(b) The firing pin (13) comes out.
NOTE: You can see the mounting hole for the safety pin with the warning flag.
(c) Make sure that the rubber pad of the INSERTION TOOL shows face to the firing pin housing (17). (d) Hold the tool 995022 INSERTION TOOL-PIN,OXYGEN GENERATOR in position and put the AIPC 35-21-41-99-020 SAFETY PIN WITH THE WARNING FLAG (12) into the mounting hole.
(e) Remove the tool 995022 INSERTION TOOL-PIN,OXYGEN GENERATOR.
(f) Make sure that the waved part of the safety pin with the warning flag (12) points away from the eyelet of the release pin (15).
(5) Disconnect the pull flags (7) from the snap hooks (6) of the masks (8).
(6) Pull the release pin (15) from the firing pin (13).
(a) Remove the release pin (15) together with the mask lanyards (5).
(7) Remove the mask supply hoses (9) from outlets of the outlet manifold (11) (Ref. AMM TASK 35-21-43-000-001).
(8) If necessary, discard the oxygen generator (3).
NOTE: If you have an oxygen generator (3) that is made by Rockwell Collins, refer to the related Component Maintenance Manual (CMM) for the discard procedure. It is necessary to send the component operation results to the manufacturer.
B. Removal of the Oxygen Generator from the Emergency Oxygen Container Type II
(2) Remove the loops of the mask lanyards (1) from the snap hook (2) of the oxygen masks (3).
(3) Carefully remove the oxygen masks (3) from the emergency oxygen container (12).
(4) Disconnect the ejector strips (6) from the slots of the emergency oxygen container (12).
(5) Release the spring bridle (5) and carefully remove the oxygen generator (7).
(a) Remove the housing of the firing pin (16) from the foam pad (10).
(6) Install the safety pin with the warning flag (9):
(a) Carefully put the 995022 INSERTION TOOL-PIN,OXYGEN GENERATOR between the housing of the firing pin (16) and the release pin (11).
(b) The firing pin (16) comes out.
(d) Hold the tool 995022 INSERTION TOOL-PIN,OXYGEN GENERATOR in position and put the AIPC 35-21-41-99-020 SAFETY RING PIN WITH THE WARNING FLAG (9) or AIPC 35-21-89-99-020 SAFETY PIN WITH THE WARNING FLAG (9) into the mounting hole.
1 Remove the tool 995022 INSERTION TOOL-PIN,OXYGEN GENERATOR.
2 Make sure that the waved part of the AIPC 35-21-41-99-020 SAFETY RING PIN WITH THE WARNING FLAG (9) or AIPC 35-21-89-99-020 SAFETY PIN WITH THE WARNING FLAG (9) points away from the eyelet of the release pin (11).
(e) If installed, disconnect the pull flag(s) (15) from the snap hook(s) (2) of the masks (3).
(7) Pull the lanyard (1) and remove the release pin (11) from the firing pin (16).
(8) Remove the supply hoses (4) from the outlet of the outlet manifold (13) (Ref. AMM TASK 35-21-43-000-001).
(9) If necessary, discard the oxygen generator (7).
CAUTION:
DO NOT PULL THE MASK LANYARD FROM THE END WITH THE RELEASE PIN. IF YOU PULL ON THIS END OF THE LANYARD, YOU WILL REMOVE THE RELEASE PIN AND START A FLOW OF OXYGEN WHICH CANNOT BE STOPPED.
CAUTION:
BEFORE YOU MOVE AN OXYGEN GENERATOR (WITH OR WITHOUT AN OXYGEN CONTAINER), INSTALL A SAFETY RING OR PIN AND WARNING FLAG ON ITS IGNITION ACTUATOR. YOU MUST DO THIS:
(1) Wear GLOVES - COTTON, LINT-FREE, CLEAN when you work on the oxygen system. - BEFORE YOU MOVE IT TO A DIFFERENT LOCATION
- BEFORE YOU PUT IT INTO STORAGE
- BEFORE YOU PREPARE IT FOR TRANSPORT.
(2) Remove the loops of the mask lanyards (1) from the snap hook (2) of the oxygen masks (3).
(3) Carefully remove the oxygen masks (3) from the emergency oxygen container (12).
(4) Disconnect the ejector strips (6) from the slots of the emergency oxygen container (12).
(5) Release the spring bridle (5) and carefully remove the oxygen generator (7).
(a) Remove the housing of the firing pin (16) from the foam pad (10).
(6) Install the safety pin with the warning flag (9):
(a) Carefully put the 995022 INSERTION TOOL-PIN,OXYGEN GENERATOR between the housing of the firing pin (16) and the release pin (11).
(b) The firing pin (16) comes out.
NOTE: You can see the mounting hole for the safety pin with the warning flag.
(c) Make sure that the rubber pad face of the 995022 INSERTION TOOL-PIN,OXYGEN GENERATOR points to the housing of the firing pin (16). (d) Hold the tool 995022 INSERTION TOOL-PIN,OXYGEN GENERATOR in position and put the AIPC 35-21-41-99-020 SAFETY RING PIN WITH THE WARNING FLAG (9) or AIPC 35-21-89-99-020 SAFETY PIN WITH THE WARNING FLAG (9) into the mounting hole.
1 Remove the tool 995022 INSERTION TOOL-PIN,OXYGEN GENERATOR.
2 Make sure that the waved part of the AIPC 35-21-41-99-020 SAFETY RING PIN WITH THE WARNING FLAG (9) or AIPC 35-21-89-99-020 SAFETY PIN WITH THE WARNING FLAG (9) points away from the eyelet of the release pin (11).
(e) If installed, disconnect the pull flag(s) (15) from the snap hook(s) (2) of the masks (3).
(7) Pull the lanyard (1) and remove the release pin (11) from the firing pin (16).
(8) Remove the supply hoses (4) from the outlet of the outlet manifold (13) (Ref. AMM TASK 35-21-43-000-001).
(9) If necessary, discard the oxygen generator (7).
NOTE: If you have an oxygen generator (7) that is made by Rockwell Collins, refer to the related Component Maintenance Manual (CMM) for the discard procedure. It is necessary to send the component operation results to the manufacturer.