Removal of the Cabin Intercommunication Data System (CIDS) Data Converter
TASK 33-21-32-000-801-A
Removal of the Cabin Intercommunication Data System (CIDS) Data Converter
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 33-21-32-861-050-A ** ON A/C NOT FOR ALL Subtask 33-21-32-010-050-A ** ON A/C NOT FOR ALL
Subtask 33-21-32-020-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 00:53:30 UTC
Removal of the Cabin Intercommunication Data System (CIDS) Data Converter
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | 1 | SCREWDRIVER |
| No specific | 1 | STEPLADDER 1.0 M (3.3 FT) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 240 | MID PASSENGER COMPARTMENT |
| FOR [581LG] (CONVERTER-DATA) | |
| FOR [582LG] (CONVERTER-DATA) | |
| 241EC | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| FOR [581LG] (CONVERTER-DATA) | |
| FOR [582LG] (CONVERTER-DATA) | |
| TASK 25-23-41-000-001-A | Removal of the Ceiling Panels |
Subtask 33-21-32-861-050-A ** ON A/C NOT FOR ALL Subtask 33-21-32-010-050-A ** ON A/C NOT FOR ALL
B. Get Access
(1) Put a STEPLADDER 1.0 M (3.3 FT) in position.
(2) Remove the ceiling panel:
(a) FOR [581LG] (CONVERTER-DATA), [582LG] (CONVERTER-DATA)
Remove 241EC (Ref. AMM TASK 25-23-41-000-001).
Subtask 33-21-32-865-050-A ** ON A/C NOT FOR ALL (1) Put a STEPLADDER 1.0 M (3.3 FT) in position.
(2) Remove the ceiling panel:
(a) FOR [581LG] (CONVERTER-DATA), [582LG] (CONVERTER-DATA)
Remove 241EC (Ref. AMM TASK 25-23-41-000-001).
C. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | LIGHT-HATRACK-STRIP | 312LG | J05 |
Subtask 33-21-32-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the CIDS Data Converter
(2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(3) Use a SCREWDRIVER to remove the CIDS data converter (2) from the clip (1).
CAUTION:
MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
(1) (1) Disconnect the electrical connector (3).(2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(3) Use a SCREWDRIVER to remove the CIDS data converter (2) from the clip (1).
CIDS Data Converter