Removal of the Cabin Intercommunication Data System (CIDS) Data Converter


TASK 33-21-32-000-801-A
Removal of the Cabin Intercommunication Data System (CIDS) Data Converter


ZONE: 240
FIN: 581LG ** ON A/C NOT FOR ALL
FIN: 582LG ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
1
SCREWDRIVER
No specific
1
STEPLADDER 1.0 M (3.3 FT)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
240
MID PASSENGER COMPARTMENT
FOR [581LG] (CONVERTER-DATA)
FOR [582LG] (CONVERTER-DATA)
241EC
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
FOR [581LG] (CONVERTER-DATA)
FOR [582LG] (CONVERTER-DATA)
TASK 25-23-41-000-001-A
Removal of the Ceiling Panels
3. Job Set-up
Subtask 33-21-32-861-050-A ** ON A/C NOT FOR ALL
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 33-21-32-010-050-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Put a STEPLADDER 1.0 M (3.3 FT) in position.
   (2) Remove the ceiling panel:
     (a) FOR [581LG] (CONVERTER-DATA), [582LG] (CONVERTER-DATA)
Remove 241EC (Ref. AMM TASK 25-23-41-000-001).
Subtask 33-21-32-865-050-A ** ON A/C NOT FOR ALL
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2000VULIGHT-HATRACK-STRIP312LGJ05
4. Procedure
Subtask 33-21-32-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the CIDS Data Converter
CAUTION: MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
   (1) (1) Disconnect the electrical connector (3).
   (2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
   (3) Use a SCREWDRIVER to remove the CIDS data converter (2) from the clip (1).
[Rev.10 from 2021] 2026.04.01 00:53:30 UTC