Removal of the Power Supply Unit (PSU)
TASK 33-21-31-000-801-A
Removal of the Power Supply Unit (PSU)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 33-21-31-861-050-A ** ON A/C NOT FOR ALL Subtask 33-21-31-010-050-A ** ON A/C NOT FOR ALL
Subtask 33-21-31-020-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 00:53:28 UTC
Removal of the Power Supply Unit (PSU)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | 1 | STEPLADDER 1.0 M (3.3 FT) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 240 | MID PASSENGER COMPARTMENT |
| FOR [572LG] (POWER SUPPLY UNIT) | |
| 241EC | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| FOR [572LG] (POWER SUPPLY UNIT) | |
| TASK 25-23-41-000-001-A | Removal of the Ceiling Panels |
Subtask 33-21-31-861-050-A ** ON A/C NOT FOR ALL Subtask 33-21-31-010-050-A ** ON A/C NOT FOR ALL
B. Get Access
(1) Put a STEPLADDER 1.0 M (3.3 FT) in position.
(2) Remove the ceiling panel:
(a) FOR [572LG] (POWER SUPPLY UNIT)
Remove 241EC (Ref. AMM TASK 25-23-41-000-001).
Subtask 33-21-31-865-050-A ** ON A/C NOT FOR ALL (1) Put a STEPLADDER 1.0 M (3.3 FT) in position.
(2) Remove the ceiling panel:
(a) FOR [572LG] (POWER SUPPLY UNIT)
Remove 241EC (Ref. AMM TASK 25-23-41-000-001).
C. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | LIGHT-HATRACK-STRIP | 312LG | J05 |
Subtask 33-21-31-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the PSU
(2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(4) Remove the screws (3) and the washers (2).
(5) Remove the PSU (1) from its support.
CAUTION:
MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
CAUTION:
MAKE MATCH MARKS ON ALL THE ELECTRICAL WIRES BEFORE YOU DISCONNECT THEM. INCORRECT CONNECTION OF WIRES WILL CAUSE DAMAGE TO EQUIPMENT.
(1) Disconnect the electrical connectors (4) and (5) from the PSU (1).(2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
CAUTION:
MAKE SURE THAT THE ELECTRICAL CONNECTOR(S) IS(ARE) DISCONNECTED BEFORE YOU DISCONNECT THE BONDING STRAP(S).
(3) Remove the nut (7) and the bonding strap (6) from the PSU (1).(4) Remove the screws (3) and the washers (2).
(5) Remove the PSU (1) from its support.
Power Supply Unit (PSU)