Installation of the Aft-Cargo Drain-Heating Heater-Elements
TASK 30-71-56-400-001-A
Installation of the Aft-Cargo Drain-Heating Heater-Elements
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 30-71-56-860-050-F ** ON A/C NOT FOR ALL
Subtask 30-71-56-420-050-B ** ON A/C NOT FOR ALL
Subtask 30-71-56-410-050-F ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 00:32:10 UTC
Installation of the Aft-Cargo Drain-Heating Heater-Elements
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
ZONE: 150
FIN: 10DU ** ON A/C NOT FOR ALL
FIN: 22DU ** ON A/C NOT FOR ALL
FIN: 87DU ** ON A/C NOT FOR ALL
FIN: 88DU ** ON A/C NOT FOR ALL
FIN: 89DU ** ON A/C NOT FOR ALL
FIN: 90DU ** ON A/C NOT FOR ALL
1. Reason for the JobFIN: 10DU ** ON A/C NOT FOR ALL
FIN: 22DU ** ON A/C NOT FOR ALL
FIN: 87DU ** ON A/C NOT FOR ALL
FIN: 88DU ** ON A/C NOT FOR ALL
FIN: 89DU ** ON A/C NOT FOR ALL
FIN: 90DU ** ON A/C NOT FOR ALL
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ELEC CONTACTS INSERTION EXTRACTION TOOL M15570-20 |
| No specific | AR | TIE WRAP(S) |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.05TAB1) | Adhesive Tape-- Glass Cloth - |
| (Material No.08BAA9) | Non Aqueous Cleaner-General - - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 150 | AFT CARGO COMPARTMENT FWD PRESS BULKHEAD TO AFT BULKHEAD OF AFT CARGO COMPARTMENT |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
| TASK 30-71-00-710-002-A | Operational Test of the Waste-Water Ice-Protection Heater-Elements |
| TASK 52-30-00-860-006-A | Open the Bulk Cargo-Compartment Door |
| TASK 53-42-14-000-001-A | Removal of the Aft Cargo-Compartment Floor-Panels Zone 150 |
| TASK 53-42-14-400-001-A | Installation of the Aft Cargo-Compartment Floor-Panels Zone 150 |
| TASK 53-42-14-400-001-A-01 | Installation of the Aft Cargo-Compartment Floor-Panels (Alternative Installation Procedure with the Skyflex Option) |
Subtask 30-71-56-860-050-F ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Make sure that the ground service network is energized (Ref. AMM TASK 24-42-00-861-001).
(2) Make sure that the BULK cargo-compartment door is open (Ref. AMM TASK 52-30-00-860-006).
(3) Make sure that the SERVICE LIGHT switch is ON.
(4) Make sure that the following cargo-compartment floor panels are removed
(Ref. AMM TASK 53-42-14-000-001):
(a) FOR [87DU] (HEATER-TAPE, WASTE WTR)
151SG,
(b) FOR [88DU] (HEATER-TAPE, WASTE WTR)
151SG, 151DF,
(c) FOR [89DU] (HEATER-TAPE, WASTE WTR)
151DF, 151GF
(d) FOR [90DU] (HEATER-TAPE, WASTE WTR)
151GF.
Subtask 30-71-56-865-054-A ** ON A/C NOT FOR ALL (1) Make sure that the ground service network is energized (Ref. AMM TASK 24-42-00-861-001).
(2) Make sure that the BULK cargo-compartment door is open (Ref. AMM TASK 52-30-00-860-006).
(3) Make sure that the SERVICE LIGHT switch is ON.
(4) Make sure that the following cargo-compartment floor panels are removed
(Ref. AMM TASK 53-42-14-000-001):
(a) FOR [87DU] (HEATER-TAPE, WASTE WTR)
151SG,
(b) FOR [88DU] (HEATER-TAPE, WASTE WTR)
151SG, 151DF,
(c) FOR [89DU] (HEATER-TAPE, WASTE WTR)
151DF, 151GF
(d) FOR [90DU] (HEATER-TAPE, WASTE WTR)
151GF.
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
Subtask 30-71-56-140-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2001VU | POT/WASTE WIP-HEATER-LINE | 31DW | D03 |
| 2001VU | POT/WASTE WIP HEATER CTL | 32DW | D02 |
| 2001VU | WASTE WIP-HEATER-LINE | 22DU | E04 |
| 2001VU | WASTE WIP-HEATER-LINE | 31DU | E04 |
| 2001VU | WASTE WIP-HEATER-CTL | 10DU | E03 |
C. Preparation for Installation
(2) Do an inspection of the component interfaces and the adjacent area.
4. ProcedureWARNING:
YOU MUST ALWAYS WEAR RUBBER GLOVES WHEN YOU DO THIS PROCEDURE.
(1) Clean the waste water line with Non Aqueous Cleaner-General - - (Material No.08BAA9) and a Textile-Lint free Cotton - (Material No.14SBA1) . (2) Do an inspection of the component interfaces and the adjacent area.
Subtask 30-71-56-420-050-B ** ON A/C NOT FOR ALL
A. Installation of a Heater Element (Example)
(1) Put the heater element (1) in position on the waste water tube (5).
(a) Make sure that the heater element (1) is correctly installed on the waste water tube (5).
(3) Safety the two ends of the Adhesive Tape-- Glass Cloth - (Material No.05TAB1) with TIE WRAP(S) as an alternative to the shrinkable sleeve (2).
(4) Electrical connections:
(5) If removed, install the related temperature sensor.
(6) Attach the identification and warning labels and the electrical wires of the heater element (1) with the cable-ties.
Subtask 30-71-56-865-057-A ** ON A/C NOT FOR ALL (1) Put the heater element (1) in position on the waste water tube (5).
NOTE: It not permitted to bend the heater element (1) in the Y-axis. The minimum bending radius in the X-axis is 25 mm (0.9843 in.).
(2) Install the Adhesive Tape-- Glass Cloth - (Material No.05TAB1) (4) in a ring-shape to attach the heater element (1) on the waste water tube (5). (a) Make sure that the heater element (1) is correctly installed on the waste water tube (5).
(3) Safety the two ends of the Adhesive Tape-- Glass Cloth - (Material No.05TAB1) with TIE WRAP(S) as an alternative to the shrinkable sleeve (2).
(4) Electrical connections:
CAUTION:
REFER TO THE MATCH MARKS MADE DURING THE REMOVAL WHEN YOU CONNECT THE ELECTRICAL WIRES.
IF YOU MAKE AN ERROR WHEN YOU CONNECT THE WIRES YOU WILL CAUSE DAMAGE TO EQUIPMENT.
CAUTION:
MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
(a) Connect the electrical connections (3) with the ELEC CONTACTS INSERTION EXTRACTION TOOL M15570-20. (5) If removed, install the related temperature sensor.
(6) Attach the identification and warning labels and the electrical wires of the heater element (1) with the cable-ties.
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 30-71-56-710-050-B ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2001VU | POT/WASTE WIP-HEATER-LINE | 31DW | D03 |
| 2001VU | POT/WASTE WIP HEATER CTL | 32DW | D02 |
| 2001VU | WASTE WIP-HEATER-LINE | 22DU | E04 |
| 2001VU | WASTE WIP-HEATER-LINE | 31DU | E04 |
| 2001VU | WASTE WIP-HEATER-CTL | 10DU | E03 |
C. The applicable heater elements are controlled and monitored by control unit 80DU. Nevertheless, do the BITE test of the waste-water ice-protection system (Ref. AMM TASK 30-71-00-710-002).
5. Close-upSubtask 30-71-56-410-050-F ** ON A/C NOT FOR ALL
A. Close Access
(1) Install the following cargo-compartment floor panels
(Ref. AMM TASK 53-42-14-400-001):
(a) FOR [87DU] (HEATER-TAPE, WASTE WTR)
151SG,
(b) FOR [88DU] (HEATER-TAPE, WASTE WTR)
151SG, 151DF,
(c) FOR [89DU] (HEATER-TAPE, WASTE WTR)
151DF, 151GF
(d) FOR [90DU] (HEATER-TAPE, WASTE WTR)
151GF.
(2) Set the SERVICE LIGHT switch to OFF.
(3) Close the BULK cargo-compartment door (Ref. AMM TASK 52-30-00-860-006).
Subtask 30-71-56-862-050-A ** ON A/C NOT FOR ALL (1) Install the following cargo-compartment floor panels
(Ref. AMM TASK 53-42-14-400-001):
(a) FOR [87DU] (HEATER-TAPE, WASTE WTR)
151SG,
(b) FOR [88DU] (HEATER-TAPE, WASTE WTR)
151SG, 151DF,
(c) FOR [89DU] (HEATER-TAPE, WASTE WTR)
151DF, 151GF
(d) FOR [90DU] (HEATER-TAPE, WASTE WTR)
151GF.
(2) Set the SERVICE LIGHT switch to OFF.
(3) Close the BULK cargo-compartment door (Ref. AMM TASK 52-30-00-860-006).
Heater Elements - Removal/Installation