W DOC AIRBUS | AMM A320F

Removal of the Hydraulic Inline Damper


TASK 29-13-46-000-803-A
Removal of the Hydraulic Inline Damper


WARNING: BE CAREFUL WHEN YOU DO WORK ON THE ENGINE AFTER SHUTDOWN. THE ENGINE CAN STAY HOT FOR A LONG TIME. IF YOU DO NOT OBEY THIS INSTRUCTION, INJURY CAN OCCUR.
WARNING: YOU MUST NOT GET HYDRAULIC FLUID ON YOUR SKIN, IN YOUR EYES OR IN YOUR MOUTH. THE HYDRAULIC FLUID IS POISONOUS AND CAN BE ABSORBED INTO YOUR BODY. IF YOU ACCIDENTALLY GET HYDRAULIC FLUID IN YOUR EYES, MOUTH OR ON YOUR SKIN, FLUSH WITH WATER AND GET MEDICAL AID.
WARNING: OBEY THE HYDRAULIC SAFETY PROCEDURES.
CAUTION: HYDRAULIC FLUID CAN CAUSE DAMAGE TO EQUIPMENT. IF HYDRAULIC FLUID FALLS ON A SURFACE, IMMEDIATELY CLEAN THE SURFACE WITH A CLEAN CLOTH.
ZONE: 460
FIN: 3031GM ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
COVER - PROTECTION
No specific
AR
WARNING NOTICE(S)
No specific
1
WRENCH - STANDARD
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.PU10-0013)
container - 0.25 gal. (1 L)
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
460
ENG 2 THRUST REVERSER & EXHAUST SECTION
195BB, 198CB
FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL, 448AR, 462AR
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 29-10-00-864-002-A
Depressurize the Yellow Hydraulic System
TASK 29-14-00-614-001-A
Depressurization of the Hydraulic Reservoirs
TASK 71-00-00-860-833-A
Procedure to Prevent Engine Motoring
TASK 71-13-00-010-802-A
Opening of the Fan Cowl Doors
TASK 78-30-00-040-805-A
Deactivation of the Thrust Reverser System for Ground Maintenance
TASK 78-36-00-010-802-A
Opening of the Thrust Reverser Cowl-Doors
3. Job Set-up
Subtask 29-13-46-860-056-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Make sure that the Yellow hydraulic system is depressurized.
(Ref. AMM TASK 29-10-00-864-002)
   (2) Depressurize the reservoir of the Yellow hydraulic system.
(Ref. AMM TASK 29-14-00-614-001)
Subtask 29-13-46-941-052-A ** ON A/C NOT FOR ALL
B. Safety Precautions
   (1) On AIR COND panel 30VU:
  • Make sure that the APU BLEED pushbutton switch is released (the ON legend is off).
  • Put a WARNING NOTICE(S) in position to tell persons not to operate this pushbutton switch.
   (2) Open access door 198CB.
     (a) On the ground service panel, put WARNING NOTICE(S) in position to tell persons not to pressurize the Yellow hydraulic system.
   (3) On the HYD section of panel 40VU:
     (a) Put WARNING NOTICE(S) in position to tell persons not to pressurize the Yellow hydraulic system.
   (4) Open access door 195BB:
     (a) Put a WARNING NOTICE(S) in position to tell persons not to pressurize the reservoir of the Yellow hydraulic system.
   (5) Do the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833).
Subtask 29-13-46-010-054-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-802):
     (a) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL 448AR
Subtask 29-13-46-040-050-A ** ON A/C NOT FOR ALL
D. Deactivation of the Thrust Reverser for Maintenance
WARNING: YOU MUST DEACTIVATE THE THRUST REVERSER BEFORE YOU DO WORK ON OR AROUND IT. IF YOU DO NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE AN INJURY AND/OR DAMAGE.
   (1) Do the deactivation of the thrust reverser system for maintenance (Ref. AMM TASK 78-30-00-040-805).
Subtask 29-13-46-010-055-A ** ON A/C NOT FOR ALL
E. Get Access
   (1) Open the right thrust-reverser cowl-door (Ref. AMM TASK 78-36-00-010-802):
     (a) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
462AR.
4. Procedure
Subtask 29-13-46-020-052-A ** ON A/C NOT FOR ALL
A. Removal of the Hydraulic Inline Damper
CAUTION: YOU MUST USE A WRENCH TO HOLD THE MATING PARTS WHEN YOU LOOSEN OR TIGHTEN THE TUBE NUTS. IF YOU DO NOT OBEY THIS CAUTION, YOU CAN TWIST OR CAUSE DAMAGE TO THE TUBES.
CAUTION: WIPE CLEAN ALL PARTS AND TOOLS AS NECESSARY TO REMOVE UNWANTED DEBRIS AND PREVENT DAMAGE TO THE ENGINE.
   (1) Put a PU10-0013container - 0.25 gal. (1 L) below the hydraulic pump connections to collect the remaining fluid.
   (2) Remove the hydraulic inline damper (1).
     (a) Hold the hydraulic inline damper (1) with a WRENCH - STANDARD and disconnect the hydraulic pressure hose from the hydraulic inline damper (1) on the hydraulic pump.
     (b) Collect the hydraulic fluid in the PU10-0013container - 0.25 gal. (1 L).
     (c) Remove the hydraulic inline damper (1) from the hydraulic pump.
     (d) Remove and discard the packings (2), (4) and two retainers (3) from the hydraulic inline damper (1).
   (3) Installation of the protection covers
CAUTION: INSTALL PROTECTION COVERS ON ALL THE OPENINGS IMMEDIATELY TO PREVENT DAMAGE TO THE ENGINE.
     (a) Install COVER - PROTECTION on the hydraulic pressure hose and hydraulic pump.
[Rev.10 from 2021] 2026.04.01 00:21:52 UTC