W DOC AIRBUS | AMM A320F

Removal of the Self Sealing Half-Coupling of the Yellow Pump Suction


TASK 29-13-39-000-805-A
Removal of the Self Sealing Half-Coupling of the Yellow Pump Suction


WARNING: OBEY THE HYDRAULIC SAFETY PROCEDURES.
WARNING: DO NOT TOUCH THE HYDRAULIC SYSTEM COMPONENTS FOR A SHORT TIME AFTER THE ENGINE IS SHUTDOWN. THE ENGINE COMPONENTS STAY HOT FOR SOME TIME AND CAN CAUSE INJURY.
CAUTION: DO NOT LET HYDRAULIC FLUID FALL ON THE ENGINE. UNWANTED HYDRAULIC FLUID MUST BE REMOVED IMMEDIATELY WITH A CLEAN LINT FREE CLOTH. THE FLUID CAN CAUSE DAMAGE TO THE SURFACE PROTECTION AND TO SOME PARTS.
ZONE: 400
FIN: 3700GM ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
1
CONTAINER 10 L(2 1/2 USGAL)
No specific
AR
PLUG - BLANKING
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
400
POWER PLANT, NACELLES AND PYLONS
195BB, 198CB
FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL, 448AR, 462AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 29-10-00-864-002-A
Depressurize the Yellow Hydraulic System
TASK 29-14-00-614-001-A
Depressurization of the Hydraulic Reservoirs
TASK 71-00-00-860-833-A
Procedure to Prevent Engine Motoring
TASK 71-13-00-010-802-A
Opening of the Fan Cowl Doors
TASK 78-30-00-040-805-A
Deactivation of the Thrust Reverser System for Ground Maintenance
TASK 78-36-00-010-802-A
Opening of the Thrust Reverser Cowl-Doors
3. Job Set-up
Subtask 29-13-39-860-060-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Make sure that the Yellow hydraulic system is depressurized.
(Ref. AMM TASK 29-10-00-864-002)
   (2) Depressurize the reservoir of the Yellow hydraulic system.
(Ref. AMM TASK 29-14-00-614-001)
Subtask 29-13-39-941-060-A ** ON A/C NOT FOR ALL
B. Safety Precautions
   (1) On AIR COND panel 30VU:
  • Make sure that the APU BLEED pushbutton switch is released (the ON legend is off).
  • Put a WARNING NOTICE(S) in position to tell persons not to operate this pushbutton switch.
   (2) Open access door 198CB.
     (a) Put WARNING NOTICE(S) in position to tell persons not to pressurize the Yellow hydraulic system on the ground service panel.
   (3) On the HYD section of panel 40VU:
  • Put WARNING NOTICE(S) in position to tell persons not to pressurize the Yellow hydraulic system.
   (4) Open access door 195BB:
     (a) Put a WARNING NOTICE(S) in position to tell persons not to pressurize the reservoir of the Yellow hydraulic system.
   (5) Do the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833).
Subtask 29-13-39-010-055-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-802):
     (a) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL 448AR
Subtask 29-13-39-040-050-A ** ON A/C NOT FOR ALL
D. Deactivation of the Thrust Reverser for Maintenance
WARNING: YOU MUST DEACTIVATE THE THRUST REVERSER BEFORE YOU DO WORK ON OR AROUND IT. IF YOU DO NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE AN INJURY AND/OR DAMAGE.
   (1) Do the deactivation of the thrust reverser system for maintenance (Ref. AMM TASK 78-30-00-040-805).
Subtask 29-13-39-010-057-A ** ON A/C NOT FOR ALL
E. Get Access
   (1) Open the right thrust-reverser cowl-door (Ref. AMM TASK 78-36-00-010-802):
     (a) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
462AR
   (2) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
4. Procedure
Subtask 29-13-39-020-055-A ** ON A/C NOT FOR ALL
A. Removal of the Self Sealing Half-Coupling of the Yellow Pump Suction
CAUTION: USE TWO WRENCHES TO REMOVE OR INSTALL THE TUBE COUPLING NUTS:
  • ONE WRENCH TO HOLD THE UNION, AND
  • ONE TO LOOSEN OR TIGHTEN THE COUPLING NUT.
THIS PREVENTS DAMAGE TO THE PARTS.
   (1) Put a CONTAINER 10 L(2 1/2 USGAL) below the hydraulic connections to collect the remaining fluid.
   (2) Disconnect the hose half-coupling (6) from the self sealing half-coupling (3).
   (3) Remove and discard the retainer (5) and the packing (4) from the fluid disconnect panel (3).
   (4) Remove the self sealing half-coupling (3) from the pylon fuel-hydraulic panel (1).
   (5) Remove and discard the packing (2) from the self sealing half-coupling (3).
   (6) Put a PLUG - BLANKING on the disconnected hose half-coupling (6) and the port of the pylon fuel-hydraulic panel (1).
[Rev.10 from 2021] 2026.04.01 00:21:01 UTC