W DOC AIRBUS | AMM A320F

Drainage of the Reservoir of the Blue Hydraulic System


TASK 29-10-00-680-003-A
Drainage of the Reservoir of the Blue Hydraulic System


FIN: 2000GQ
1. Reason for the Job
NOTE: If the hydraulic reservoir is too full, it is necessary to adjust the fluid level accurately. It is not necessary to drain the hydraulic reservoir fully.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
CONTAINER - HYDRAULIC FLUID RESISTANT
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
2
WARNING NOTICE(S)
No specific
2
WRENCH - STANDARD
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
195BB, 197EB
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 12-12-29-611-001-A
Fill the Hydraulic Fluid Reservoir with a Hand Pump
TASK 12-12-29-611-002-A
Fill the Hydraulic Fluid Reservoir with a Hydraulic Service Cart
TASK 29-00-00-864-001-A
Put the Related Hydraulic System in the Depressurized Configuration before Maintenance Action
TASK 29-00-00-910-002-A
Safety Procedures of the Hydraulic System
TASK 29-14-00-614-001-A
Depressurization of the Hydraulic Reservoirs
3. Job Set-up
Subtask 29-10-00-865-075-A
A. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUHYD/HYD PWR/B WARN/& CTL2702GJC12
121VUHYDRAULIC/LOW/LVL/IND1832GQN32
121VUHYDRAULIC/HYD/QTY/IND1831GQP35
123VUB HYD/ELEC PUMP2701GJAB09
Subtask 29-10-00-941-058-A
B. Safety Precautions
   (1) Put the WARNING NOTICE(S) in position to tell persons not to pressurize the Blue hydraulic system:
  • In the cockpit on hydraulic section 40VU of the overhead panel
  • On the ground service panel of the Blue hydraulic system.
Subtask 29-10-00-010-071-A
C. Open access doors 195BB 197EB.
Subtask 29-10-00-860-061-A
D. Aircraft Maintenance Configuration
WARNING: OBEY THE HYDRAULIC SAFETY PROCEDURES.
   (1) Obey the hydraulic safety procedures (Ref. AMM TASK 29-00-00-910-002).
   (2) Make sure that the Blue hydraulic system is depressurized and put it in the maintenance configuration.
(Ref. AMM TASK 29-00-00-864-001).
   (3) Depressurize the reservoir of the Blue hydraulic system (Ref. AMM TASK 29-14-00-614-001).
   (4) Put the CONTAINER - HYDRAULIC FLUID RESISTANT in position so that you can drain the hydraulic fluid into it.
NOTE: The reservoir and its related pipes contain 30 l (7.9251 USgal) of hydraulic fluid when full.
4. Procedure
Subtask 29-10-00-680-052-A
A. Drainage of the Reservoir
NOTE: The drain valve of the reservoir of the Blue hydraulic system is on the ground service panel of the Blue hydraulic system.
   (1) Remove flexible hose 1699GM from its stowage on the ground service panel of the Green hydraulic system.
   (2) Connect the flexible hose to the reservoir drain valve.
NOTE: It is necessary to use the WRENCH - STANDARD to hold the body of the reservoir drain valve when the flexible hose is connected.
   (3) Put the other end of the flexible hose in the container.
   (4) Turn the drain valve counter-clockwise.
NOTE: When you turn the drain valve counter-clockwise, no fluid will flow until you push the valve in.
   (5) Push the drain valve in and turn the valve clockwise to lock the drain valve in the open position.
   (6) When the reservoir is empty, turn the drain valve counter-clockwise and release.
   (7) Turn the drain valve clockwise to lock it in the closed position.
5. Close-up
Subtask 29-10-00-860-062-A
A. Put the aircraft back to the serviceable condition.
   (1) Disconnect the flexible hose from the reservoir drain valve.
NOTE: It is necessary to use the WRENCH - STANDARD to hold the body of the reservoir drain valve when the flexible hose is disconnected.
   (2) Make sure that the flexible hose contains no hydraulic fluid.
   (3) Put the flexible hose in its stowage on the ground service panel of the Green hydraulic system.
   (4) Fill the Blue reservoir with a hand pump (Ref. AMM TASK 12-12-29-611-001), or with a hydraulic service cart (Ref. AMM TASK 12-12-29-611-002).
   (5) Remove the container.
   (6) Remove the WARNING NOTICE(S).
Subtask 29-10-00-410-071-A
B. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close access doors 195BB 197EB.
Subtask 29-10-00-865-076-A
C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUHYD/HYD PWR/B WARN/& CTL2702GJC12
121VUHYDRAULIC/LOW/LVL/IND1832GQN32
121VUHYDRAULIC/HYD/QTY/IND1831GQP35
123VUB HYD/ELEC PUMP2701GJAB09
[Rev.10 from 2021] 2026.04.01 04:31:15 UTC