W DOC AIRBUS | AMM A320F

Discard Battery of Survival Emergency Locator Transmitter


TASK 25-65-32-920-801-A
Discard Battery of Survival Emergency Locator Transmitter


WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
CAUTION: DO NOT SET THE EMERGENCY LOCATOR TRANSMITTER (ELT) SLIDE SWITCH TO ON. THIS IS TO PREVENT UNWANTED SEARCH AND RESCUE OPERATIONS.
ZONE: 200
FIN: 7559MM ** ON A/C NOT FOR ALL
FIN: 7560MM ** ON A/C NOT FOR ALL
1. Reason for the Job
Refer to the MPD TASK: 256532-04
DISCARD BATTERY OF SURVIVAL EMERGENCY LOCATOR TRANSMITTER.
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
200
UPPER HALF FUSELAGE
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
TASK 25-65-32-000-001-A
Removal of the Portable Emergency Locator Transmitter (ELT)
TASK 25-65-32-400-001-A
Installation of the Portable Emergency Locator Transmitter (ELT)
TASK 25-65-00-00
MISCELLANEOUS EMERGENCY EQUIPMENT - DESCRIPTION AND OPERATION
3. Job Set-up
Subtask 25-65-32-861-051-A ** ON A/C NOT FOR ALL
A. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 25-65-32-010-051-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) For the location of this component, refer to paragraph Component Location
(Ref. AMM D/O 25-65-00-00).
4. Procedure
Subtask 25-65-32-920-050-A ** ON A/C NOT FOR ALL
A. Removal/Installation of Survival Emergency Locator Transmitter (ELT) for Workshop Maintenance
   (1) Remove the survival ELT (Ref. AMM TASK 25-65-32-000-001).
   (2) Send the survival ELT to the workshop.
   (3) Install a serviceable survival ELT (Ref. AMM TASK 25-65-32-400-001).
5. Close-up
Subtask 25-65-32-410-051-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
Subtask 25-65-32-862-051-A ** ON A/C NOT FOR ALL
B. De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
[Rev.10 from 2021] 2026.03.31 23:41:17 UTC