Remove Survival Emergency Locator Transmitter for In Shop Operational Check
TASK 25-65-00-720-802-A
Remove Survival Emergency Locator Transmitter for In Shop Operational Check
Refer to the MPD TASK: 256532-02
REMOVE SURVIVAL EMERGENCY LOCATOR TRANSMITTER FOR IN SHOP OPERATIONAL CHECK
2. Job Set-up Information
A. Work Zones and Access Panels
B. Referenced Information
3. Job Set-up
Subtask 25-65-00-861-064-A ** ON A/C NOT FOR ALL Subtask 25-65-00-861-064-J ** ON A/C NOT FOR ALL Subtask 25-65-00-861-064-O ** ON A/C NOT FOR ALL Subtask 25-65-00-010-068-A ** ON A/C NOT FOR ALL
Subtask 25-65-00-720-054-A ** ON A/C NOT FOR ALL
Subtask 25-65-00-410-068-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.03.31 23:41:01 UTC
Remove Survival Emergency Locator Transmitter for In Shop Operational Check
ZONE: 200
ZONE: 210
ZONE: 220
ZONE: 230
ZONE: 250
ZONE: 260
FIN: 7559MM ** ON A/C NOT FOR ALL
FIN: 7560MM ** ON A/C NOT FOR ALL
1. Reason for the JobZONE: 210
ZONE: 220
ZONE: 230
ZONE: 250
ZONE: 260
FIN: 7559MM ** ON A/C NOT FOR ALL
FIN: 7560MM ** ON A/C NOT FOR ALL
Refer to the MPD TASK: 256532-02
REMOVE SURVIVAL EMERGENCY LOCATOR TRANSMITTER FOR IN SHOP OPERATIONAL CHECK
2. Job Set-up Information
A. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 200 | UPPER HALF FUSELAGE |
| 210 | CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD |
| 220 | FWD CAB UTILITY AREAS |
| 230 | FWD PASSENGER COMPARTMENT |
| 250 | AFT PASSENGER COMPARTMENT |
| 260 | AFT CABIN UTILITY AREA |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
| TASK 25-65-32-000-001-A | Removal of the Portable Emergency Locator Transmitter (ELT) |
| TASK 25-65-32-400-001-A | Installation of the Portable Emergency Locator Transmitter (ELT) |
| TASK 25-65-00-00 | MISCELLANEOUS EMERGENCY EQUIPMENT - DESCRIPTION AND OPERATION |
Subtask 25-65-00-861-064-A ** ON A/C NOT FOR ALL Subtask 25-65-00-861-064-J ** ON A/C NOT FOR ALL Subtask 25-65-00-861-064-O ** ON A/C NOT FOR ALL Subtask 25-65-00-010-068-A ** ON A/C NOT FOR ALL
B. Get Access
(1) For the location of this component, refer to Para. Component Location (Ref. AMM D/O 25-65-00-00).
(2) Open the door/access panel of the stowage compartment.
(4) If a clamp holds the ELT, open it.
(5) Remove the ELT from the stowage compartment.
Subtask 25-65-00-010-068-J ** ON A/C NOT FOR ALL Subtask 25-65-00-010-068-O ** ON A/C NOT FOR ALL (1) For the location of this component, refer to Para. Component Location (Ref. AMM D/O 25-65-00-00).
(2) Open the door/access panel of the stowage compartment.
NOTE: Placards show the location of the Emergency Locator Transmitter (ELT). The placards are bonded to the outer side of the stowage compartment.
(3) If a strap holds the ELT, release it. (4) If a clamp holds the ELT, open it.
(5) Remove the ELT from the stowage compartment.
B. Get Access
(1) Open the door/access panel of the stowage compartment(s).
(3) Remove the ELT(s) from the stowage compartment(s).
4. Procedure(1) Open the door/access panel of the stowage compartment(s).
NOTE: The location of the ELT(s) are shown with placards, which are bonded on the outside of the stowage compartment(s).
(2) If necessary release/open the strap/clamp. (3) Remove the ELT(s) from the stowage compartment(s).
Subtask 25-65-00-720-054-A ** ON A/C NOT FOR ALL
A. Workshop Procedure
(1) Send the ELT to the workshop for an operational check.
Subtask 25-65-00-720-054-C ** ON A/C NOT FOR ALL (1) Send the ELT to the workshop for an operational check.
A. Workshop Procedure
(1) Send the ELT to the workshop for an operational check.
Subtask 25-65-00-720-054-O ** ON A/C NOT FOR ALL (1) Send the ELT to the workshop for an operational check.
A. Workshop Procedure
5. Close-upCAUTION:
DO THE TEST IN THE SCREENED ROOM.
IF THE SCREENED ROOM IS NOT AVAILABLE, DO THE TEST DURING THE FIRST FIVE MINUTES AFTER THE HOUR.
(BETWEEN XX.00 HRS AND XX:05 HRS) IF YOU MUST DO THE TEST AT A DIFFERENT TIME, FIRST TELL THE NEAREST AIR TRAFFIC CONTROL FACILITY TO IGNORE THE SIGNAL DURING THE TEST. MAKE SURE THAT THE TEST SIGNAL IS NOT LONGER THAN THREE TONES.
THIS IS TO PREVENT UNWANTED RESCUE OPERATIONS.
(1) Send the Emergency Locator Transmitter (ELT) to the workshop.Subtask 25-65-00-410-068-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Do a check of the ELT attachment(s) (strap, clamp and/or bag) for wear, contamination and environmental degradation. Make sure that the attachment(s) is (are) in a serviceable condition.
(2) Install the ELT on the stowage compartment.
(3) Attach the strap.
(4) Close the clamp.
(5) Close the door/access panel of the stowage compartment.
(6) Make sure that the work area is clean and clear of tools and other items.
Subtask 25-65-00-410-068-J ** ON A/C NOT FOR ALL Subtask 25-65-00-410-068-O ** ON A/C NOT FOR ALL (1) Do a check of the ELT attachment(s) (strap, clamp and/or bag) for wear, contamination and environmental degradation. Make sure that the attachment(s) is (are) in a serviceable condition.
(2) Install the ELT on the stowage compartment.
(3) Attach the strap.
(4) Close the clamp.
(5) Close the door/access panel of the stowage compartment.
(6) Make sure that the work area is clean and clear of tools and other items.
A. Close Access
(1) Install a serviceable or replacement ELT(s).
(2) Attach/close the strap/clamp.
(3) Close the door/access panel of the stowage compartment(s).
(4) Make sure that the work area is clean and clear of tools and other items.
Subtask 25-65-00-862-064-A ** ON A/C NOT FOR ALL Subtask 25-65-00-862-064-J ** ON A/C NOT FOR ALL Subtask 25-65-00-862-064-O ** ON A/C NOT FOR ALL (1) Install a serviceable or replacement ELT(s).
(2) Attach/close the strap/clamp.
(3) Close the door/access panel of the stowage compartment(s).
(4) Make sure that the work area is clean and clear of tools and other items.
ELT - Component Location