Remove Emergency Exit/Offwing Reservoir and Valve Assembly for Inflation Reservoir in Shop Hydrostatic Test
TASK 25-62-00-920-803-A
Remove Emergency Exit/Offwing Reservoir and Valve Assembly for Inflation Reservoir in Shop Hydrostatic Test
1. Reason for the Job
Refer to the MPD TASK: 256241-06
REMOVE EMERGENCY EXIT/OFFWING RESERVOIR AND VALVE ASSEMBLY FOR INFLATION RESERVOIR IN SHOP HYDROSTATIC TEST.
A. Work Zones and Access Panels
B. Referenced Information
3. Job Set-up
Subtask 25-62-00-010-080-A ** ON A/C NOT FOR ALL
Subtask 25-62-00-920-052-A
Subtask 25-62-00-410-075-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.03.31 23:40:07 UTC
Remove Emergency Exit/Offwing Reservoir and Valve Assembly for Inflation Reservoir in Shop Hydrostatic Test
1. Reason for the Job
Refer to the MPD TASK: 256241-06
REMOVE EMERGENCY EXIT/OFFWING RESERVOIR AND VALVE ASSEMBLY FOR INFLATION RESERVOIR IN SHOP HYDROSTATIC TEST.
NOTE: This task is not applicable for deactivated emergency exit.
2. Job Set-up InformationA. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 100 | LOWER HALF FUSELAGE INCLUDING RADOME |
| 200 | UPPER HALF FUSELAGE |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 25-62-46-000-001-A | Removal of the Inflation Reservoir for the Offwing Escape Slide |
| TASK 25-62-46-400-001-A | Installation of the Inflation Reservoir for the Offwing Escape Slide |
| TASK 25-62-49-000-001-A | Removal of the Escape-Slide Inflation Reservoir |
| TASK 25-62-49-400-001-A | Installation of the Escape-Slide Inflation Reservoir |
Subtask 25-62-00-010-080-A ** ON A/C NOT FOR ALL
A. Get Access
(1) Remove the offwing reservoir and the valve assembly (Ref. AMM TASK 25-62-46-000-001).
Subtask 25-62-00-010-080-B ** ON A/C NOT FOR ALL (1) Remove the offwing reservoir and the valve assembly (Ref. AMM TASK 25-62-46-000-001).
A. Get Access
(1) Remove the emergency exit reservoir and the valve assembly (Ref. AMM TASK 25-62-49-000-001).
Subtask 25-62-00-010-080-D ** ON A/C NOT FOR ALL (1) Remove the emergency exit reservoir and the valve assembly (Ref. AMM TASK 25-62-49-000-001).
A. Get Access
(1) Remove the emergency exit/offwing reservoir and the valve assembly (Ref. AMM TASK 25-62-49-000-001) (Ref. AMM TASK 25-62-46-000-001).
4. Procedure(1) Remove the emergency exit/offwing reservoir and the valve assembly (Ref. AMM TASK 25-62-49-000-001) (Ref. AMM TASK 25-62-46-000-001).
Subtask 25-62-00-920-052-A
A. Workshop Procedure
(1) Send the emergency exit/offwing reservoir and the valve assembly to the workshop for the inflation reservoir hydrostatic test.
5. Close-up(1) Send the emergency exit/offwing reservoir and the valve assembly to the workshop for the inflation reservoir hydrostatic test.
Subtask 25-62-00-410-075-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Install a serviceable or a new offwing reservoir and the valve assembly (Ref. AMM TASK 25-62-46-400-001).
Subtask 25-62-00-410-075-B ** ON A/C NOT FOR ALL (1) Install a serviceable or a new offwing reservoir and the valve assembly (Ref. AMM TASK 25-62-46-400-001).
A. Close Access
(1) Install a serviceable or a new emergency exit reservoir and the valve assembly (Ref. AMM TASK 25-62-49-400-001).
Subtask 25-62-00-410-075-D ** ON A/C NOT FOR ALL (1) Install a serviceable or a new emergency exit reservoir and the valve assembly (Ref. AMM TASK 25-62-49-400-001).
A. Close Access
(1) Install a serviceable or a new emergency exit/offwing reservoir and the valve assembly (Ref. AMM TASK 25-62-49-400-001) (Ref. AMM TASK 25-62-46-400-001).
(1) Install a serviceable or a new emergency exit/offwing reservoir and the valve assembly (Ref. AMM TASK 25-62-49-400-001) (Ref. AMM TASK 25-62-46-400-001).