W DOC AIRBUS | AMM A320F

Remove Emergency Exit/Offwing Reservoir and Valve Assembly for Inflation Reservoir in Shop Hydrostatic Test


TASK 25-62-00-920-803-A
Remove Emergency Exit/Offwing Reservoir and Valve Assembly for Inflation Reservoir in Shop Hydrostatic Test


ZONE: 100
ZONE: 200
1. Reason for the Job
Refer to the MPD TASK: 256241-06
REMOVE EMERGENCY EXIT/OFFWING RESERVOIR AND VALVE ASSEMBLY FOR INFLATION RESERVOIR IN SHOP HYDROSTATIC TEST.
NOTE: This task is not applicable for deactivated emergency exit.
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
100
LOWER HALF FUSELAGE INCLUDING RADOME
200
UPPER HALF FUSELAGE
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 25-62-46-000-001-A
Removal of the Inflation Reservoir for the Offwing Escape Slide
TASK 25-62-46-400-001-A
Installation of the Inflation Reservoir for the Offwing Escape Slide
TASK 25-62-49-000-001-A
Removal of the Escape-Slide Inflation Reservoir
TASK 25-62-49-400-001-A
Installation of the Escape-Slide Inflation Reservoir
3. Job Set-up
Subtask 25-62-00-010-080-A ** ON A/C NOT FOR ALL
A. Get Access
   (1) Remove the offwing reservoir and the valve assembly (Ref. AMM TASK 25-62-46-000-001).
Subtask 25-62-00-010-080-B ** ON A/C NOT FOR ALL
A. Get Access
   (1) Remove the emergency exit reservoir and the valve assembly (Ref. AMM TASK 25-62-49-000-001).
Subtask 25-62-00-010-080-D ** ON A/C NOT FOR ALL
A. Get Access
   (1) Remove the emergency exit/offwing reservoir and the valve assembly (Ref. AMM TASK 25-62-49-000-001) (Ref. AMM TASK 25-62-46-000-001).
4. Procedure
Subtask 25-62-00-920-052-A
A. Workshop Procedure
   (1) Send the emergency exit/offwing reservoir and the valve assembly to the workshop for the inflation reservoir hydrostatic test.
5. Close-up
Subtask 25-62-00-410-075-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Install a serviceable or a new offwing reservoir and the valve assembly (Ref. AMM TASK 25-62-46-400-001).
Subtask 25-62-00-410-075-B ** ON A/C NOT FOR ALL
A. Close Access
   (1) Install a serviceable or a new emergency exit reservoir and the valve assembly (Ref. AMM TASK 25-62-49-400-001).
Subtask 25-62-00-410-075-D ** ON A/C NOT FOR ALL
A. Close Access
   (1) Install a serviceable or a new emergency exit/offwing reservoir and the valve assembly (Ref. AMM TASK 25-62-49-400-001) (Ref. AMM TASK 25-62-46-400-001).
[Rev.10 from 2021] 2026.03.31 23:40:07 UTC