W DOC AIRBUS | AMM A320F

Reactivation of the Enclosure


TASK 25-62-00-440-004-A
Reactivation of the Enclosure


1. Reason for the Job
MMEL 25-62-03B
EMERGENCY EXIT SLIDE OR SLIDE RAFT
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TASK 25-62-47-000-001-A
Removal of the Escape Slide Enclosure
TASK 25-62-47-400-001-A
Installation of the Escape Slide Enclosure
TASK 25-62-49-000-001-A
Removal of the Escape-Slide Inflation Reservoir
TASK 25-62-49-400-001-A
Installation of the Escape-Slide Inflation Reservoir
3. Job Set-up
Subtask 25-62-00-010-072-A ** ON A/C NOT FOR ALL
A. Get Access
   (1) There is no special job set-up for this task.
4. Procedure
Subtask 25-62-00-440-051-A ** ON A/C NOT FOR ALL
A. Reactivation Procedure
   (1) Replace the related inflation reservoir, if it is discharged (Ref. AMM TASK 25-62-49-000-001) (Ref. AMM TASK 25-62-49-400-001).
   (2) Replace the related escape-slide enclosure (Ref. AMM TASK 25-62-47-000-001) (Ref. AMM TASK 25-62-47-400-001).
   (3) Make an entry in the logbook to record the reactivation.