Reactivation of the Enclosure
TASK 25-62-00-440-004-A
Reactivation of the Enclosure
1. Reason for the Job
MMEL 25-62-03B
EMERGENCY EXIT SLIDE OR SLIDE RAFT
2. Job Set-up Information
A. Referenced Information
3. Job Set-up
Subtask 25-62-00-010-072-A ** ON A/C NOT FOR ALL
Subtask 25-62-00-440-051-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.03.31 23:40:05 UTC
Reactivation of the Enclosure
1. Reason for the Job
MMEL 25-62-03B
EMERGENCY EXIT SLIDE OR SLIDE RAFT
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TASK 25-62-47-000-001-A | Removal of the Escape Slide Enclosure |
| TASK 25-62-47-400-001-A | Installation of the Escape Slide Enclosure |
| TASK 25-62-49-000-001-A | Removal of the Escape-Slide Inflation Reservoir |
| TASK 25-62-49-400-001-A | Installation of the Escape-Slide Inflation Reservoir |
Subtask 25-62-00-010-072-A ** ON A/C NOT FOR ALL
A. Get Access
(1) There is no special job set-up for this task.
4. Procedure(1) There is no special job set-up for this task.
Subtask 25-62-00-440-051-A ** ON A/C NOT FOR ALL
A. Reactivation Procedure
(1) Replace the related inflation reservoir, if it is discharged (Ref. AMM TASK 25-62-49-000-001) (Ref. AMM TASK 25-62-49-400-001).
(2) Replace the related escape-slide enclosure (Ref. AMM TASK 25-62-47-000-001) (Ref. AMM TASK 25-62-47-400-001).
(3) Make an entry in the logbook to record the reactivation.
(1) Replace the related inflation reservoir, if it is discharged (Ref. AMM TASK 25-62-49-000-001) (Ref. AMM TASK 25-62-49-400-001).
(2) Replace the related escape-slide enclosure (Ref. AMM TASK 25-62-47-000-001) (Ref. AMM TASK 25-62-47-400-001).
(3) Make an entry in the logbook to record the reactivation.