Installation of the Door Microswitch
TASK 25-45-33-400-001-A
Installation of the Door Microswitch
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 25-45-33-860-050-A
Subtask 25-45-33-210-050-A
Subtask 25-45-33-862-050-A
[Rev.10 from 2021]
2026.04.01 12:33:09 UTC
Installation of the Door Microswitch
ZONE: 200
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ELEC CONTACTS INSERTION EXTRACTION TOOL M15.570-22 |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 200 | UPPER HALF FUSELAGE |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
| TASK 33-24-00-710-001-A | Operational Test of the Lavatory Lighting LQ |
| TASK 33-26-00-710-001-A | Operational Test of the Lavatory Lighted Signs WJ |
Subtask 25-45-33-860-050-A
A. Aircraft Maintenance Configuration
(1) Make sure that the ground service network is energized
(Ref. AMM TASK 24-42-00-861-001).
Subtask 25-45-33-865-051-A (1) Make sure that the ground service network is energized
(Ref. AMM TASK 24-42-00-861-001).
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | LAV FWD-OCCUPIED | 1WJ | F01 |
| ** ON A/C ALL | |||
| 2000VU | LIGHT-LAV | 1LQ | J01 |
| ** ON A/C NOT FOR ALL | |||
| 2000VU | LAV FWD & MID-OCCUPIED | 1WJ | F01 |
| ** ON A/C ALL | |||
| 2001VU | LAVATORY AFT-OCCUPIED | 11WJ | B04 |
Subtask 25-45-33-210-050-A
A. Preparation for Installation
(1) Clean the component interfaces and the adjacent area.
(2) Make sure that the parts retained from the removed component are clean and in the correct condition.
(3) Do an inspection of the component interfaces and the adjacent area.
Subtask 25-45-33-420-050-A (1) Clean the component interfaces and the adjacent area.
(2) Make sure that the parts retained from the removed component are clean and in the correct condition.
(3) Do an inspection of the component interfaces and the adjacent area.
B. Installation of the Door Microswitch
(1) Remove the CAP-BLANKING from each electrical connector and receptacle.
(2) Make sure that all the electrical connections are clean and in the correct condition.
(3) Connect the electrical connector (4) as follows:
(a) Connect the electrical connector (4).
(4) Install the screws (2).
(5) Tighten the screws (2).
(6) Make sure that the work area is clean and clear of tools and other items.
(7) Close the lavatory door.
Subtask 25-45-33-865-052-A (1) Remove the CAP-BLANKING from each electrical connector and receptacle.
(2) Make sure that all the electrical connections are clean and in the correct condition.
(3) Connect the electrical connector (4) as follows:
(a) Connect the electrical connector (4).
NOTE: Use the Insertion/Extraction tool ELEC CONTACTS INSERTION EXTRACTION TOOL M15.570-22 to connect the electical connector (3) type 'B'.
(b) Carefully position the door microswitch assembly (1) on the door frame. (4) Install the screws (2).
(5) Tighten the screws (2).
(6) Make sure that the work area is clean and clear of tools and other items.
(7) Close the lavatory door.
C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 25-45-33-710-050-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | LAV FWD-OCCUPIED | 1WJ | F01 |
| ** ON A/C ALL | |||
| 2000VU | LIGHT-LAV | 1LQ | J01 |
| ** ON A/C NOT FOR ALL | |||
| 2000VU | LAV FWD & MID-OCCUPIED | 1WJ | F01 |
| ** ON A/C ALL | |||
| 2001VU | LAVATORY AFT-OCCUPIED | 11WJ | B04 |
D. Operational of the Door Microswitch
(1) Do the operational test of the lavatory lighting (Ref. AMM TASK 33-24-00-710-001).
(2) Do the operational test of the lavatory lighted signs (Ref. AMM TASK 33-26-00-710-001).
5. Close-up(1) Do the operational test of the lavatory lighting (Ref. AMM TASK 33-24-00-710-001).
(2) Do the operational test of the lavatory lighted signs (Ref. AMM TASK 33-26-00-710-001).
Subtask 25-45-33-862-050-A
Door Microswitch