Operational Test of the Lavatory Lighted Signs WJ
TASK 33-26-00-710-001-A
Operational Test of the Lavatory Lighted Signs WJ
To make sure that the lavatory lighted signs operate correctly.
2. Job Set-up Information
A. Work Zones and Access Panels
B. Referenced Information
3. Job Set-up
Subtask 33-26-00-865-052-A
Subtask 33-26-00-860-050-A
Subtask 33-26-00-862-050-A
[Rev.10 from 2021]
2026.04.01 00:53:52 UTC
Operational Test of the Lavatory Lighted Signs WJ
ZONE: 200
1. Reason for the JobTo make sure that the lavatory lighted signs operate correctly.
2. Job Set-up Information
A. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 200 | UPPER HALF FUSELAGE |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 25-00-00-00 | EQUIPMENT/FURNISHINGS - DESCRIPTION AND OPERATION |
Subtask 33-26-00-865-052-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 33-26-00-865-051-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 122VU | LIGHTING/ANN LT SPLY/XFMR/BUS 2 | 27LP | X05 |
| ** ON A/C NOT FOR ALL | |||
| 2000VU | LAV FWD-OCCUPIED | 1WJ | F01 |
| ** ON A/C NOT FOR ALL | |||
| 2000VU | LAV FWD & MID-OCCUPIED | 1WJ | F01 |
| ** ON A/C ALL | |||
| 2001VU | LAVATORY AFT-OCCUPIED | 11WJ | B04 |
B. Make sure that this(these) circuit breaker(s) is(are) closed:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 122VU | LIGHTING/ANN LT SPLY/XFMR/BUS 2 | 27LP | X05 |
Subtask 33-26-00-860-050-A
A. Preparation for the Test
(1) Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
(2) Make sure that all lavatory doors are closed but not locked.
Subtask 33-26-00-710-050-A (1) Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
(2) Make sure that all lavatory doors are closed but not locked.
B. Operational Test
(1) Do the test of the forward lavatory lighted signs:
Subtask 33-26-00-710-052-E ** ON A/C NOT FOR ALL (1) Do the test of the forward lavatory lighted signs:
| ACTION | RESULT |
|---|---|
1.In the cockpit, on INT LT panel 25VU:
| |
2.At the lavatory A:
| In the cockpit, on overhead panel 48VU:
|
| | In Zone 220:
|
3.In the cockpit, on INT LT panel 25VU:
| In the cockpit, on overhead panel 48VU:
|
|
|
4.At the lavatory A:
| In the cockpit, on overhead panel 48VU:
|
| | In Zone 220:
|
C. Test of the MID Lavatory Lighted Signs.
(1) Do the test of the lavatory lighted signs 23WJ and 25WJ.
Subtask 33-26-00-710-051-A ** ON A/C NOT FOR ALL (1) Do the test of the lavatory lighted signs 23WJ and 25WJ.
| ACTION | RESULT |
|---|---|
1.At the lavatory door of the lavatory L:
| In Zone 230:
|
|
|
D. Test of All Lavatory Lighted Signs.
Subtask 33-26-00-710-051-D ** ON A/C NOT FOR ALL NOTE: For lavatory location refer to (Ref. AMM D/O 25-00-00-00).
(1) Do the test of the lavatory lighted signs WJ. | ACTION | RESULT |
|---|---|
1.At the related lavatory:
| In the cabin:
|
2.At the related lavatory:
| In the cabin:
|
3.At the related lavatory:
| In the cabin:
|
D. Operational Test
(1) Do the test of the aft lavatory lighted signs:
Subtask 33-26-00-710-051-E ** ON A/C NOT FOR ALL (1) Do the test of the aft lavatory lighted signs:
| ACTION | RESULT |
|---|---|
1.At the lavatory doors of the lavatories D and L:
| In Zone 260:
|
|
|
|
|
|
|
2.At the lavatory door of the lavatory M:
| In Zone 260:
|
|
|
D. Operational Test
(1) Do the test of the aft lavatory lighted signs:
Subtask 33-26-00-710-051-G ** ON A/C NOT FOR ALL (1) Do the test of the aft lavatory lighted signs:
| ACTION | RESULT |
|---|---|
1.At the lavatory doors of the lavatories D and L:
| In Zone 260:
|
|
|
|
|
|
|
2.At the lavatory door of the lavatory E:
| In Zone 260:
|
|
|
D. Operational Test
(1) Do the test of the aft lavatory lighted signs:
5. Close-up(1) Do the test of the aft lavatory lighted signs:
| ACTION | RESULT |
|---|---|
1.At the lavatories D and E:
| In Zone 260:
|
2.At lavatory D:
| In Zone 260:
|
3.At lavatory E:
| In Zone 260:
|
4.At lavatory D:
| In Zone 260:
|
5.At lavatory E:
| In Zone 260:
|
Subtask 33-26-00-862-050-A