W DOC AIRBUS | AMM A320F

Installation of the Stowage FWD RH


TASK 25-27-44-400-003-A
Installation of the Stowage FWD RH


WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
WARNING: BE CAREFUL WHEN YOU REMOVE OR INSTALL THIS EQUIPMENT. THIS EQUIPMENT IS HEAVY (MORE THAN 12 KG (26.5 lb)) AND CAN CAUSE INJURY AND/OR DAMAGE.
CAUTION: WHEN YOU MOVE A HEAVY COMPONENT, DO NOT PUSH IT ALONG THE CABIN FLOOR OR LET IT RUB AGAINST THE FLOOR. IF YOU DO, YOU CAN CAUSE DAMAGE TO THE CABIN FLOOR AND/OR THE COMPONENT.
ZONE: 230
FIN: 6579MM ** ON A/C NOT FOR ALL
FIN: 6580MM ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ELEC CONTACTS INSERTION EXTRACTION TOOL M15570-20
No specific
1
SCRAPER - NON METALLIC
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.03HBD9)
Synthetic Ester base Grease-General Purpose Low Temp -
(Material No.06CMD9)
Silicone Adhesive Sealant-General Purpose One part legacy
(Material No.08BAA9)
Non Aqueous Cleaner-General - -
(Material No.08BBF1)
Non Aqueous Cleaner_- Methyl-Ethyl-Ketone -
(Material No.12AFC3)
Corrosion Preventive Compound-Hot application Soft Film Turbine Engine
(Material No.14SBA1)
Textile-Lint free Cotton -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
230
FWD PASSENGER COMPARTMENT
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 11-00-00-400-007-A
Installation of the ESSO (Scotchcal Labels)
TASK 20-21-11-911-001-A
Tightening Torques for Standard Threaded Fasteners
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
TASK 25-26-41-400-001-A
Installation of the Forward Curtain Rail
F Stowage ** ON A/C NOT FOR ALL
F Stowage ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 25-27-44-860-054-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Make sure that the ground service network is energized
(Ref. AMM TASK 24-42-00-861-001).
   (2) Make sure that the stowage is empty.
Subtask 25-27-44-865-062-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2000VULIGHT - STWG100LZJ04
** ON A/C NOT FOR ALL
2000VUCAB LIGHT PWR-WINDOW-FWD300LGH01
4. Procedure
Subtask 25-27-44-210-056-A ** ON A/C NOT FOR ALL
A. Preparation for Installation
   (1) Clean the seat tracks and/or the floor panels with Non Aqueous Cleaner_- Methyl-Ethyl-Ketone - (Material No.08BBF1) , a Textile-Lint free Cotton - (Material No.14SBA1) and a SCRAPER - NON METALLIC.
   (2) Clean the component interfaces and the adjacent area.
   (3) Do an inspection of the component interfaces and the adjacent area.
   (4) Make sure that the parts retained from the removed component are clean and in the correct condition.
Subtask 25-27-44-420-051-CG ** ON A/C NOT FOR ALL
WARNING: SUPPORT THE UNIT/ASSEMBLY. THE UNIT/ASSEMBLY IS HEAVY. IF YOU DO NOT SUPPORT IT, IT WILL FALL. THIS CAN CAUSE INJURY TO PERSONS, AND/OR DAMAGE TO EQUIPMENT.
B. Installation of the Stowage 6580MM
F Stowage ** ON A/C NOT FOR ALL
   (1) Unless specified, TORQUE all nuts, bolts and screws (Ref. AMM TASK 20-21-11-911-001).
   (2) Apply Synthetic Ester base Grease-General Purpose Low Temp - (Material No.03HBD9) to the seat-track fittings (13).
   (3) Put the seat-track fittings (13) in the seat tracks (14) as recorded in the removal procedure.
   (4) Put the shim plates (12) in position as recorded in the removal procedure.
   (5) Carefully put the stowage (1) in position.
   (6) Put the shim plates (17) in position as recorded in the removal procedure.
   (7) Install the floor cups (16), the outer eccentric-bushes (9) and the inner eccentric-bushes (8).
   (8) Turn the eccentric-bushes (8) and (9) clockwise or counterclockwise to adjust the horizontal position of the stowage (1).
   (9) Put the shim plates (7) in position as recorded in the removal procedure.
   (10) Install the washers (6) and the nuts (5).
   (11) Put the shim plates (15) in position as recorded in the removal procedure.
   (12) Put the covers (10) in position and install the screws (11).
   (13) Put the upper attachments (4) in position and install the screws (3).
   (14) Make sure that all placards of the retained/new components are in the correct position and in good condition.
   (15) If necessary, install new placards (Ref. AMM TASK 11-00-00-400-007).
   (16) Close the door (2).
Subtask 25-27-44-210-056-C ** ON A/C NOT FOR ALL
C. Preparation for Installation
F Stowage ** ON A/C NOT FOR ALL
   (1) Clean the seat tracks:
WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
     (a) Clean the seat rails (tracks) with Non Aqueous Cleaner-General - - (Material No.08BAA9) , a Textile-Lint free Cotton - (Material No.14SBA1) and a SCRAPER - NON METALLIC.
     (b) Ensure the seat rails (tracks) are clean and the paint/protective coatings are free of cracks and other defects.
   (2) Clean the component interfaces and the adjacent area.
   (3) Do an inspection of the component interfaces and the adjacent area.
   (4) Make sure that the parts retained from the removed component are clean and in the correct condition.
   (5) Apply one coat of P/N AV-30 corrosion inhibitor compound to the seat rails (tracks) in the area of closet installation.
   (6) Locate the seat-track fittings (14) in the seat rails (tracks) (15) as recorded in the removal procedure.
   (7) Fill the seat rails (tracks) lugs under closet footprint with corrosion preventative compound Corrosion Preventive Compound-Hot application Soft Film Turbine Engine (Material No.12AFC3) by heating to flowing consistency.
   (8) Cover the lugs filled with grease using P/N JLARII (or equivalent) clear tape.
Subtask 25-27-44-420-051-AR ** ON A/C NOT FOR ALL
WARNING: SUPPORT THE UNIT/ASSEMBLY. THE UNIT/ASSEMBLY IS HEAVY. IF YOU DO NOT SUPPORT IT, IT WILL FALL. THIS CAN CAUSE INJURY TO PERSONS, AND/OR DAMAGE TO EQUIPMENT.
D. Installation of the Stowage 6580MM
F Stowage ** ON A/C NOT FOR ALL
   (1) Unless specified, TORQUE all nuts, bolts and screws
(Ref. AMM TASK 20-21-11-911-001).
   (2) Carefully put the stowage (1) near to the installation position to connect the electrical connectors (6).
   (3) Connect the electrical connectors as applicable:
     (a) Remove the CAP-BLANKING from each electrical connector and receptacle.
     (b) Make sure that all the electrical connections are clean and in the correct condition.
     (c) Connect the electrical connectors (6), use the ELEC CONTACTS INSERTION EXTRACTION TOOL M15570-20.
   (4) Carefully put the stowage (1) in position.
   (5) Install the threaded bushes (14).
   (6) Turn the threaded bushes (14) clockwise or counterclockwise to adjust the vertical position of the stowage (1).
   (7) Put the outer eccentric-bushes (13) and the inner eccentric-bushes (12) in position.
   (8) Turn the eccentric bushes (12) and (13) clockwise or counterclockwise to adjust the horizontal position of the stowage (1).
   (9) Put the cover-plates (11) in position and install the bolts (10).
   (10) Seal the bolts:
WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
     (a) Encapsulate the bolts (10) with adhesive sealant (5) Silicone Adhesive Sealant-General Purpose One part legacy (Material No.06CMD9) .
   (11) Put the covers (15) in position and install the screws (16).
   (12) Put the footrest (4) in position and install the screws (3).
   (13) Make sure that all of the placards of the retained/new components are in the correct position and in good condition.
   (14) If necessary install new placards (Ref. AMM TASK 11-00-00-400-007).
   (15) Close the door (2).
Subtask 25-27-44-865-063-A ** ON A/C NOT FOR ALL
E. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2000VULIGHT - STWG100LZJ04
** ON A/C NOT FOR ALL
2000VUCAB LIGHT PWR-WINDOW-FWD300LGH01
Subtask 25-27-44-710-073-A ** ON A/C NOT FOR ALL
F. Do these Tests
   (1) Do a test of the stowage catches and latch assemblies for satisfactory function.
   (2) Do a test of the stowage door(s) and door hinges for free movement.
Subtask 25-27-44-710-074-A ** ON A/C NOT FOR ALL
G. Do these Tests
   (1) Do a test of the stowage catches and latch-assemblies for satisfactory function.
   (2) Do a test of the stowage door(s) and door-hinges for free movement.
   (3) Do the operational test of the stowage light.
ACTION
RESULT
1.On the stowage:
  • Open the door.
In the stowage:
  • The related light comes on.
2.On the stowage:
  • Close the door.
In the stowage:
  • The related light goes off.
5. Close-up
Subtask 25-27-44-410-051-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Install the equipment in the stowage as identified in the removal procedure.
   (2) Make sure that the work area is clean and clear of tools and other items.
   (3) Make sure that the stowage door(s) is(are) closed and locked.
Subtask 25-27-44-410-051-Q ** ON A/C NOT FOR ALL
A. Close Access
   (1) Install the forward curtain and curtain rail (Ref. AMM TASK 25-26-41-400-001).
   (2) Install the equipment in the stowage, as identified in the removal procedure.
   (3) Install the literature pockets and the baby bassinet, if necessary.
   (4) Make sure that the work area is clean and clear of tools and other items.
   (5) Make sure that the stowage door(s) is (are) closed and locked.
Subtask 25-27-44-862-051-A ** ON A/C NOT FOR ALL
B. De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
[Rev.10 from 2021] 2026.04.01 03:48:55 UTC