Installation of the Advanced Power Converter(s)
TASK 25-21-36-400-802-A
Installation of the Advanced Power Converter(s)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Job Set-up
Subtask 25-21-36-860-051-A ** ON A/C NOT FOR ALL Subtask 25-21-36-865-056-A ** ON A/C NOT FOR ALL
Subtask 25-21-36-210-051-A ** ON A/C NOT FOR ALL
Subtask 25-21-36-862-051-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.03.31 23:30:22 UTC
Installation of the Advanced Power Converter(s)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | CAP - PROTECTION |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 20-28-00-912-802-A | Electrical Bonding - General Maintenance Procedure |
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
| TASK 25-21-00-710-002-A | Operational Test of the In-Seat Power-Supply System (PED Power Supply) |
Subtask 25-21-36-860-051-A ** ON A/C NOT FOR ALL Subtask 25-21-36-865-056-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | INSEAT POWER-MCU 2 | 59HP | B08 |
| 2000VU | INSEAT POWER-MCU 1 | 58HP | B05 |
Subtask 25-21-36-210-051-A ** ON A/C NOT FOR ALL
A. Preparation for Installation
(1) Clean the component interfaces and the adjacent area.
(2) Do an inspection of the component interfaces and the adjacent area.
Subtask 25-21-36-420-051-A ** ON A/C NOT FOR ALL (1) Clean the component interfaces and the adjacent area.
(2) Do an inspection of the component interfaces and the adjacent area.
B. Installation of the advanced power converter
(1) Put the advanced power converter (6) in position and lock the fasteners (3).
(2) Connect the electrical connectors:
(b) Remove the CAP-BLANKING from each electrical connector and receptacle.
(c) Make sure that all the electrical connections are clean and in the correct condition.
(d) Connect the electrical connectors (7) and (4) to the advanced power converter (6).
(e) Lock the electrical connectors (4) with the spring latches (5).
(f) Make sure that all not used connectors have a CAP - PROTECTION.
(3) Put the covers (1) in position and lock the fasteners (2).
(4) Make sure that the work area is clean and clear of tools and other items.
Subtask 25-21-36-865-057-A ** ON A/C NOT FOR ALL (1) Put the advanced power converter (6) in position and lock the fasteners (3).
(2) Connect the electrical connectors:
CAUTION:
MAKE SURE THAT THE BONDING STRAP(S) IS(ARE) CONNECTED BEFORE YOU CONNECT THE ELECTRICAL CONNECTOR(S).
CAUTION:
MAKE SURE THAT THE SPRING LATCHES CORRECTLY HOLD THE CONNECTOR IN THE FULLY ENGAGED POSITION. THE SPRING LATCHES PREVENT UNWANTED MOVEMENT OF THE CONNECTOR, AND THUS THE RISK OF ARCING, WHICH CAN CAUSE DAMAGE TO THE UNIT.
(a) Install the bonding straps (10) with the washers (9) and the nuts (8) (Ref. AMM TASK 20-28-00-912-802). (b) Remove the CAP-BLANKING from each electrical connector and receptacle.
(c) Make sure that all the electrical connections are clean and in the correct condition.
(d) Connect the electrical connectors (7) and (4) to the advanced power converter (6).
(e) Lock the electrical connectors (4) with the spring latches (5).
(f) Make sure that all not used connectors have a CAP - PROTECTION.
(3) Put the covers (1) in position and lock the fasteners (2).
(4) Make sure that the work area is clean and clear of tools and other items.
C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 25-21-36-710-051-A ** ON A/C NOT FOR ALL 5. Close-up| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | INSEAT POWER-MCU 2 | 59HP | B08 |
| 2000VU | INSEAT POWER-MCU 1 | 58HP | B05 |
Subtask 25-21-36-862-051-A ** ON A/C NOT FOR ALL
Advanced Power Converter