W DOC AIRBUS | AMM A320F

Operational Test of the Captain (First Officer) Seat Inboard Armrest-Assy


TASK 25-11-65-710-001-A
Operational Test of the Captain (First Officer) Seat Inboard Armrest-Assy


ZONE: 211
ZONE: 212
1. Reason for the Job
To make sure that the Captain (First Officer) seat inboard armrest-assy operates correctly.
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
211
COCKPIT
212
COCKPIT
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
3. Job Set-up
Subtask 25-11-65-860-051-A
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
4. Procedure
Subtask 25-11-65-710-050-A
A. Operational Test of the Captain (First Officer) Inboard Seat Armrest-Assy
ACTION
RESULT
1.On the inboard armrest:

  • Push the button and lift the armrest to a position less than 90 degrees.
  • The armrest moves correctly.
  • Release the button.
  • The armrest stays in position.
  • Push the button, lift the armrest to the vertical position and turn it behind the backrest.
  • The armrest is in its stowage position.
  • Release the button.
  • The armrest stays in its stowage position.
5. Close-up
Subtask 25-11-65-860-052-A
A. De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-42-00-862-001).
[Rev.10 from 2021] 2026.03.31 23:28:18 UTC