W DOC AIRBUS | AMM A320F

Apply Temporary Protection to End Fittings of Electrical Conduits in Dry Bay (Outboard)


TASK 24-92-00-210-015-A
Apply Temporary Protection to End Fittings of Electrical Conduits in Dry Bay (Outboard)


WARNING: MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
  • THE FLIGHT CONTROLS
  • THE FLIGHT CONTROL SURFACES
  • THE LANDING GEAR AND THE RELATED DOORS
  • COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE EQUIPMENT.
WARNING: MAKE SURE THAT YOU OBEY ALL THE WARNINGS AND THE CAUTIONS INCLUDED IN THE REFERENCED PROCEDURES.
WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
ZONE: 560
ZONE: 660
1. Reason for the Job
Refer to the MPD TASK: 240000-10
APPLY TEMPORARY PROTECTION TO END FITTINGS OF ELECTRICAL CONDUITS IN DRY BAY (OUTBOARD)
Apply temporary protection to end fittings of electrical conduits in the dry bay (outboard).
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
No specific
AR
BRUSH - BRISTLED
No specific
AR
SPRAY - BOTTLE, PUMP TYPE (NON AEROSOL)
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.08BAA9)
Non Aqueous Cleaner-General - -
(Material No.12ACB1)
Corrosion Preventive Compound-Heavy Duty Hard Film -
(Material No.14SBA1)
Textile-Lint free Cotton -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
560
DRY BAY (OUTBOARD)
660
DRY BAY (OUTBOARD)
560AB, 660AB
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 12-34-24-869-002-A
Aircraft Grounding (Earthing) for the Maintenance Operations
TASK 12-34-24-869-002-A-01
Aircraft Grounding (Earthing) during Transit, Turnaround or Overnight Stop
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 57-27-11-000-002-A
Removal of the Access Panel
TASK 57-27-11-400-002-A
Installation of the Access Panel
ESPM 203330
F Typical Fittings ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 24-92-00-862-062-A ** ON A/C NOT FOR ALL
A. De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
Subtask 24-92-00-869-075-A ** ON A/C NOT FOR ALL
B. Connect the aircraft to the ground (Ref. AMM TASK 12-34-24-869-002).
Subtask 24-92-00-010-062-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at the dry bay.
   (2) For the left wing.
     (a) Remove and retain the access panel: 560AB (Ref. AMM TASK 57-27-11-000-002).
   (3) For the right wing.
     (a) Remove and retain the access panel: 660AB (Ref. AMM TASK 57-27-11-000-002).
4. Procedure
Subtask 24-92-00-210-062-A ** ON A/C NOT FOR ALL
A. Temporary Protection of the Electrical Conduits End-Fittings in the Dry Bay (Outboard)
F Typical Fittings ** ON A/C NOT FOR ALL
WARNING: BE CAREFUL NOT TO CUT YOUR FINGERS. FLAKES OF NICKEL ARE SHARP.
   (1) At each fitting use the procedure that follows to protect against corrosion:
     (a) Use Non Aqueous Cleaner-General - - (Material No.08BAA9) and a Textile-Lint free Cotton - (Material No.14SBA1) to remove any contamination from the fitting.
     (b) Remove any flakes or blisters, make sure that the you do not damage the base metal while you do this task.
NOTE: We recommend that you use a dental tool or a seal tool (non metallic) to remove the flakes and the blisters.
     (c) Use a BRUSH - BRISTLED or an SPRAY - BOTTLE, PUMP TYPE (NON AEROSOL) to apply a continuous thin and smooth coat of Corrosion Preventive Compound-Heavy Duty Hard Film - (Material No.12ACB1) , to cover all the fitting ESPM 203330.
5. Close-up
Subtask 24-92-00-410-063-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) For the left wing.
     (a) Install the access panel: 560AB (Ref. AMM TASK 57-27-11-400-002).
   (3) For the right wing.
     (a) Install the access panel: 660AB (Ref. AMM TASK 57-27-11-400-002).
   (4) Disconnect the aircraft from the ground (Ref. AMM TASK 12-34-24-869-002).
   (5) Remove the access platform(s).