W DOC AIRBUS | AMM A320F

Reactivation of the Programming and Test Panel - Emergency System Test, Cabin Emergency Lighting System


TASK 23-73-00-440-007-A
Reactivation of the Programming and Test Panel - Emergency System Test, Cabin Emergency Lighting System


FIN: 110RH ** ON A/C NOT FOR ALL
1. Reason for the Job
MMEL 23-74-01A
SYS TEST PB ON THE PTP (FAA ONLY)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TASK 11-00-00-000-003-A
Removal of the Pressurized Area Placards
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TSM 23-73-00-810-856
PTP - Fault in the Programming and Test Panel
3. Job Set-up
Subtask 23-73-00-860-203-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002)
4. Procedure
Subtask 23-73-00-040-062-A ** ON A/C NOT FOR ALL
A. Reactivation of the Programming and Test Panel (PTP)
   (1) Do the trouble shooting for the defective PTP.
TSM 23-73-00-810-856
   (2) Remove the placard "INOP" from the reactivated system (Ref. AMM TASK 11-00-00-000-003).
5. Close-up
Subtask 23-73-00-860-204-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
   (1) Make sure that the work area is clean and clear of tools and other items.