Removal of the Cockpit Voice Recorder (CVR)
TASK 23-71-35-000-001-A
Removal of the Cockpit Voice Recorder (CVR)
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 23-71-35-020-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 04:23:51 UTC
Removal of the Cockpit Voice Recorder (CVR)
WARNING:
MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT. UNWANTED ELECTRICAL POWER CAN BE DANGEROUS.
WARNING:
PUT WARNING NOTICES IN THE COCKPIT TO TELL PERSONS NOT TO OPERATE THE FLIGHT CONTROLS.
THE MOVEMENT OF THE TRIMMABLE HORIZONTAL STABILIZER (THS) CAN CAUSE INJURY TO PERSONS.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE |
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 312 | AFT FUSLG TAIL SECTION |
| 312AR |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 31-39-33-000-801-A | Removal of the Cockpit Voice and Data Recorder (CVDR) and the Umbrella Panels |
NOTE: The procedure is valid for the Cockpit Voice Recorder (CVR) and Solid State Cockpit Voice Recorder (SSCVR).
Subtask 23-71-35-861-050-A ** ON A/C NOT FOR ALL A. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 23-71-35-861-050-B ** ON A/C NOT FOR ALL (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
A. Aircraft Maintenance Configuration
(1) No special job set-up is necessary for this task.
Subtask 23-71-35-865-055-A (1) No special job set-up is necessary for this task.
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 23-71-35-010-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | COM/CVR/SPLY | 2RK | E14 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | COM/CVR/SPLY | 23RK | E14 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | RCDR1 CVR&FDR | 40TU | E14 |
C. Get Access
(1) Put the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position at zone 312.
(2) Open access door 312AR.
4. Procedure(1) Put the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position at zone 312.
(2) Open access door 312AR.
Subtask 23-71-35-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Cockpit Voice Recorder (CVR)
Solid State Cockpit Voice Recorder (SSCVR) ** ON A/C NOT FOR ALL
Solid State Cockpit Voice Recorder (SSCVR) ** ON A/C NOT FOR ALL
(1) Loosen the knurled nuts (4) and lower the fasteners.
(2) Carefully remove the CVR (1) from the rack (2).
(3) Make sure that you do not damage the pins of the electrical connectors (3).
(4) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
Subtask 23-71-35-020-050-B ** ON A/C NOT FOR ALL
Solid State Cockpit Voice Recorder (SSCVR) ** ON A/C NOT FOR ALL
Solid State Cockpit Voice Recorder (SSCVR) ** ON A/C NOT FOR ALL (2) Carefully remove the CVR (1) from the rack (2).
(3) Make sure that you do not damage the pins of the electrical connectors (3).
(4) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.