General Visual Inspection of Flap Track No 2 and Fairing (EWIS)
TASK 05-25-30-200-001-A
General Visual Inspection of Flap Track No 2 and Fairing (EWIS)
Refer to the MPD TASK: ZL-531-01
GENERAL VISUAL INSPECTION OF FLAP TRACK NO 2 AND FAIRING (EWIS)
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 05-25-30-010-050-A ** ON A/C NOT FOR ALL
Subtask 05-25-30-210-050-A
Subtask 05-25-30-866-051-A Subtask 05-25-30-410-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.03.31 22:50:11 UTC
General Visual Inspection of Flap Track No 2 and Fairing (EWIS)
WARNING:
DO NOT EXTEND THE SLATS AND FLAPS WHEN THE THRUST REVERSER COWLS ARE DEPLOYED. IF YOU DO NOT OBEY THIS WARNING, YOU CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO THE COMPONENTS.
WARNING:
MAKE SURE THAT THE SAFETY DEVICES AND THE WARNING NOTICES ARE IN POSITION BEFORE YOU START A TASK ON OR NEAR:
1. Reason for the Job- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND RELATED DOORS
- COMPONENTS THAT MOVE.
Refer to the MPD TASK: ZL-531-01
GENERAL VISUAL INSPECTION OF FLAP TRACK NO 2 AND FAIRING (EWIS)
NOTE: This is an EWIS (Electrical Wiring Interconnection System) procedure. EWIS is defined in ESPM 20-33-11.
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 3M (10 FT) |
| No specific | AR | WARNING NOTICE(S) |
| 98L12003001000 | AR | HARNESS,SAFETY |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 531 | FLAP TRACK 2 FAIRING |
| 631 | FLAP TRACK 2 FAIRING |
| 531AT, 631AT |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 27-50-00-866-008-A | Extension of the Flaps on the Ground |
| TASK 27-50-00-866-008-A-01 | Extension of the Flaps/Slats on the Ground |
| TASK 27-50-00-866-009-A | Retraction of the Flaps on the Ground |
| TASK 27-50-00-866-009-A-01 | Retraction of the Flaps/Slats on the Ground |
| TASK 57-55-11-000-001-A | Removal of the Flap Track Fairings Nos. 2, 3 and 4 |
| TASK 57-55-11-000-004-A | Removal of the Flap Track Fairings Nos. 2, 3 and 4 |
| TASK 57-55-11-400-001-A | Installation of the Flap Track Fairings Nos. 2, 3 and 4 |
| TASK 57-55-11-400-004-A | Installation of the Flap Track Fairings Nos. 2, 3 and 4 |
Subtask 05-25-30-010-050-A ** ON A/C NOT FOR ALL
A. Get Access
(1) Put the ACCESS PLATFORM 3M (10 FT) in position.
(3) Remove access panels 531AT and 631AT (Ref. AMM TASK 57-55-11-000-001).
Subtask 05-25-30-010-050-B ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 3M (10 FT) in position.
WARNING:
BEFORE YOU START WORK, YOU MUST PUT ON A SAFETY HARNESS AND ATTACH IT TO THE ACCESS PLATFORM. WITHOUT A SAFETY HARNESS, YOU CAN FALL. THIS CAN KILL YOU OR CAUSE YOU INJURY.
(2) Put on and attach the HARNESS, SAFETY before you start work in the work area.(3) Remove access panels 531AT and 631AT (Ref. AMM TASK 57-55-11-000-001).
A. Get Access
(1) Put the ACCESS PLATFORM 3M (10 FT) in position.
(3) Remove access panels 531AT and 631AT (Ref. AMM TASK 57-55-11-000-004).
Subtask 05-25-30-866-050-A Subtask 05-25-30-941-074-A (1) Put the ACCESS PLATFORM 3M (10 FT) in position.
WARNING:
BEFORE YOU START WORK, YOU MUST PUT ON A SAFETY HARNESS AND ATTACH IT TO THE ACCESS PLATFORM. WITHOUT A SAFETY HARNESS, YOU CAN FALL. THIS CAN KILL YOU OR CAUSE YOU INJURY.
(2) Put on and attach the HARNESS, SAFETY before you start work in the work area.(3) Remove access panels 531AT and 631AT (Ref. AMM TASK 57-55-11-000-004).
C. Safety Precautions
(1) Put the WARNING NOTICE(S) in the cockpit to tell persons not to operate the flight controls.
4. Procedure(1) Put the WARNING NOTICE(S) in the cockpit to tell persons not to operate the flight controls.
Subtask 05-25-30-210-050-A
A. Inspection
(1) Do a general visual inspection of flap track no. 2 and the related fairing.
(2) Make sure that there are no signs of corrosion, cracks or damage on all the parts of the components and the structure that you can see.
(3) Make sure that all the installations (wiring) are correctly attached.
5. Close-up(1) Do a general visual inspection of flap track no. 2 and the related fairing.
(2) Make sure that there are no signs of corrosion, cracks or damage on all the parts of the components and the structure that you can see.
(3) Make sure that all the installations (wiring) are correctly attached.
Subtask 05-25-30-866-051-A Subtask 05-25-30-410-050-A ** ON A/C NOT FOR ALL
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install access panels 531AT and 631AT (Ref. AMM TASK 57-55-11-400-001).
(3) Remove the access platform(s).
Subtask 05-25-30-410-050-B ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Install access panels 531AT and 631AT (Ref. AMM TASK 57-55-11-400-001).
(3) Remove the access platform(s).
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install access panels 531AT and 631AT (Ref. AMM TASK 57-55-11-400-004).
(3) Remove the access platform(s).
Subtask 05-25-30-942-068-A (1) Make sure that the work area is clean and clear of tools and other items.
(2) Install access panels 531AT and 631AT (Ref. AMM TASK 57-55-11-400-004).
(3) Remove the access platform(s).
C. Put the Aircraft back to its Initial Configuration
(1) Remove the WARNING NOTICE(S).
(2) Remove all the fixtures, tools, test and support equipment used during this procedure.
(1) Remove the WARNING NOTICE(S).
(2) Remove all the fixtures, tools, test and support equipment used during this procedure.
Access Panels of the Flap Track Fairings