GENERAL VISUAL INSPECTION OF AFT CABIN OVERHEAD COMPARTMENT (EWIS)
TASK 05-22-60-200-003-A
GENERAL VISUAL INSPECTION OF AFT CABIN OVERHEAD COMPARTMENT (EWIS)
1. Reason for the Job
Refer to the MPD TASK: ZL-263-01
GENERAL VISUAL INSPECTION OF AFT CABIN OVERHEAD COMPARTMENT (EWIS)
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 05-22-60-010-052-A
Subtask 05-22-60-210-052-A
Subtask 05-22-60-410-052-A
[Rev.10 from 2021]
2026.03.31 22:49:22 UTC
GENERAL VISUAL INSPECTION OF AFT CABIN OVERHEAD COMPARTMENT (EWIS)
1. Reason for the Job
Refer to the MPD TASK: ZL-263-01
GENERAL VISUAL INSPECTION OF AFT CABIN OVERHEAD COMPARTMENT (EWIS)
NOTE: This is an EWIS (Electrical Wiring Interconnection System) procedure. EWIS is defined in ESPM 20-33-11.
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 263 | AFT CABIN OVERHEAD COMPARTMENT |
| 264 | AFT CABIN OVERHEAD COMPARTMENT |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 25-23-42-000-002-A | Removal of the Ceiling Panels - Aft Utility Area |
| TASK 25-23-42-400-002-A | Installation of the Ceiling Panels - Aft Utility Area |
| TASK 25-24-41-000-001-A | Removal of the Overhead Stowage Compartments (OHSC) |
| TASK 25-24-41-400-001-A | Installation of the Overhead Stowage Compartments (OHSC) |
| TASK 52-10-00-010-001-A | Opening of the Passenger/Crew Door |
| TASK 52-10-00-410-001-A | Closing of the Passenger/Crew Door |
| TASK 25-33-00-00 | AFT GALLEY - DESCRIPTION AND OPERATION |
| TASK 25-43-00-00 | AFT LAVATORIES - DESCRIPTION AND OPERATION |
Subtask 05-22-60-010-052-A
A. Get Access
(1) Put an ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position at zone 832 (842).
(2) Open AFT passenger/crew door 832 (842) (Ref. AMM TASK 52-10-00-010-001).
(3) Remove the galleys and lavatories between FR64 and FR70, if installed.
To do this, refer to the para. Component Location in the applicable ATA 25 Description/Operation: for the galleys (Ref. AMM D/O 25-33-00-00), for the lavatories (Ref. AMM D/O 25-43-00-00). In this paragraph, you will find the cross-references of the removal/installation tasks.
(4) Remove the overhead stowage compartments, if installed (Ref. AMM TASK 25-24-41-000-001).
(5) Remove the ceiling panels from FR64 to FR70
(Ref. AMM TASK 25-23-42-000-002).
(6) Lift the insulation blankets sufficiently to do the inspection.
4. Procedure(1) Put an ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position at zone 832 (842).
(2) Open AFT passenger/crew door 832 (842) (Ref. AMM TASK 52-10-00-010-001).
(3) Remove the galleys and lavatories between FR64 and FR70, if installed.
To do this, refer to the para. Component Location in the applicable ATA 25 Description/Operation: for the galleys (Ref. AMM D/O 25-33-00-00), for the lavatories (Ref. AMM D/O 25-43-00-00). In this paragraph, you will find the cross-references of the removal/installation tasks.
(4) Remove the overhead stowage compartments, if installed (Ref. AMM TASK 25-24-41-000-001).
(5) Remove the ceiling panels from FR64 to FR70
(Ref. AMM TASK 25-23-42-000-002).
(6) Lift the insulation blankets sufficiently to do the inspection.
Subtask 05-22-60-210-052-A
A. Do a general visual inspection of the aft-cabin overhead compartment.
Make sure that:
5. Close-upMake sure that:
- There is no damage (corrosion, leaks or cracks) on all the parts of the components and the structure that you can see.
- All the installations (wiring, piping or ducting) are attached correctly.
Subtask 05-22-60-410-052-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Put the insulation blankets back in position.
(3) Install the ceiling panels from FR64 to FR70
(Ref. AMM TASK 25-23-42-400-002).
(4) Install the overhead stowage compartments, if removed (Ref. AMM TASK 25-24-41-400-001).
(5) Install the galleys and lavatories between FR64 and FR70, if removed.
To do this, refer to the para. Component Location in the applicable ATA 25 Description/Operation: for the galleys (Ref. AMM D/O 25-33-00-00), for the lavatories (Ref. AMM D/O 25-43-00-00). In this paragraph, you will find the cross-references of the removal/installation tasks.
(6) Close AFT passenger/crew door 832 (842) (Ref. AMM TASK 52-10-00-410-001).
(7) Remove the access platform(s).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Put the insulation blankets back in position.
(3) Install the ceiling panels from FR64 to FR70
(Ref. AMM TASK 25-23-42-400-002).
(4) Install the overhead stowage compartments, if removed (Ref. AMM TASK 25-24-41-400-001).
(5) Install the galleys and lavatories between FR64 and FR70, if removed.
To do this, refer to the para. Component Location in the applicable ATA 25 Description/Operation: for the galleys (Ref. AMM D/O 25-33-00-00), for the lavatories (Ref. AMM D/O 25-43-00-00). In this paragraph, you will find the cross-references of the removal/installation tasks.
(6) Close AFT passenger/crew door 832 (842) (Ref. AMM TASK 52-10-00-410-001).
(7) Remove the access platform(s).