Odours and mist in the cabin and not fire
TASK 26-15-00-810-804-A
Odours and mist in the cabin and not fire
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 26-15-00-710-055-A
Subtask 26-15-00-810-053-B ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:39:01 UTC
Odours and mist in the cabin and not fire
1. Possible Causes
- line between the APU and the APU BLEED VALVE
[8MD]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 38-41-00-810-803-A | Potable Water System - Relief Pressure Failure |
| TSM TASK 49-00-00-810-921-A | Fumes in the Cabin/Oil Smoke at the APU Exhaust (APS 3200) |
| TSM TASK 49-00-81-810-874-A | Fumes in the Cabin/Oil Smoke at the APU Exhaust (131-9(A)) |
| AMM 21-00-00-615-001 | Decontamination of the Environmental Control System (ECS) when the Temperature is below 24 deg.C (APU) |
| AMM 21-00-00-615-002 | Decontamination of the Environmental Control System (ECS) when the Temperature is above 24 deg.C (APU) |
| AMM 31-50-00-710-001 | Ground Scanning of the Central Warning System |
| AMM 38-42-51-000-001 | Removal of the Compressor |
| AMM 38-42-51-400-001 | Installation of the Compressor |
Subtask 26-15-00-710-055-A
A. Not applicable, you cannot confirm this fault on the ground.
4. Fault IsolationSubtask 26-15-00-810-053-B ** ON A/C NOT FOR ALL
A. If there are odours and mist:
(1) carefully examine the APU externally and make sure that you do not find leaks on the oil system components or oil lines.
(a) If you do not find external oil leaks:
(a) Do a check of the [8MD] and replace it, if necessary AMM 38-42-51-000-001 and AMM 38-42-51-400-001.
(b) Do a check for relief pressure failure (Ref. TSM TASK 38-41-00-810-803).
Subtask 26-15-00-810-053-C ** ON A/C NOT FOR ALL (1) carefully examine the APU externally and make sure that you do not find leaks on the oil system components or oil lines.
(a) If you do not find external oil leaks:
- remove the line between the APU and the APU BLEED VALVE .
- check the contamination (Ref. TSM TASK 49-00-00-810-921).
- decontaminate the lines AMM 21-00-00-615-001 or AMM 21-00-00-615-002.
(a) Do a check of the
(b) Do a check for relief pressure failure (Ref. TSM TASK 38-41-00-810-803).
A. If there are odours and mist:
(1) carefully examine the APU externally and make sure that you do not find leaks on the oil system components or oil lines.
(a) If you do not find external oil leaks:
(a) Do a check of the COMPRESSOR [8MD] and replace it, if necessary AMM 38-42-51-000-001 and AMM 38-42-51-400-001.
(b) Do a check for relief pressure failure (Ref. TSM TASK 38-41-00-810-803).
Subtask 26-15-00-865-051-A (1) carefully examine the APU externally and make sure that you do not find leaks on the oil system components or oil lines.
(a) If you do not find external oil leaks:
- remove the line between the APU and the APU BLEED VALVE .
- check the contamination (Ref. TSM TASK 49-00-81-810-874).
- decontaminate the lines AMM 21-00-00-615-001 or AMM 21-00-00-615-002.
(a) Do a check of the COMPRESSOR [8MD] and replace it, if necessary AMM 38-42-51-000-001 and AMM 38-42-51-400-001.
(b) Do a check for relief pressure failure (Ref. TSM TASK 38-41-00-810-803).
B. Table of the circuit breakers used in this procedure:
Subtask 26-15-00-710-056-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | FWS/FWC1/SPLY | 3WW | F01 |
| 121VU | EIS/FWC2/SPLY | 2WW | Q07 |
C. Test
(1) Reset of the FWC1 and FWC2
1 2WW
2 3WW
(b) Close this(these) circuit breaker(s):
1 2WW
2 3WW
(2) Do the ground scanning of the central warning system AMM 31-50-00-710-001.
(1) Reset of the FWC1 and FWC2
NOTE: Open the circuit breakers for some seconds before you close them.
(a) Open this(these) circuit breaker(s):1 2WW
2 3WW
(b) Close this(these) circuit breaker(s):
1 2WW
2 3WW
(2) Do the ground scanning of the central warning system AMM 31-50-00-710-001.