Potable Water System - Relief Pressure Failure
TASK 38-41-00-810-803-A
Potable Water System - Relief Pressure Failure
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 38-41-00-710-054-A 4. Fault Isolation
Subtask 38-41-00-810-052-A
Subtask 38-41-00-710-055-A
[Rev.8 from Aug 2018]
2026.04.04 04:34:17 UTC
Potable Water System - Relief Pressure Failure
1. Possible Causes
- VALVE-PRESSURE REDUCING [4200MM]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 38-41-00-710-001 | Operational Test of the Air Supply System (with ground air supply) |
| AMM 38-41-00-820-001 | Adjustment of the Pressure Reducing and Relief Valve |
| AMM 38-41-43-000-001 | Removal of the Pressure Reducing Valve |
| AMM 38-41-43-400-001 | Installation of the Pressure Reducing Valve |
Subtask 38-41-00-710-054-A 4. Fault Isolation
Subtask 38-41-00-810-052-A
A. If the cracking pressure of the VALVE-PRESSURE REDUCING [4200MM] is incorrect:
5. Close-up- do the adjustment of the relief valve AMM 38-41-00-820-001.
- replace the VALVE-PRESSURE REDUCING [4200MM] , AMM 38-41-43-000-001 and AMM 38-41-43-400-001.
Subtask 38-41-00-710-055-A
A. Do the test as given in paragraph 3. A. and make sure that system operates correctly.