Fumes in the Cabin/Oil Smoke at the APU Exhaust (131-9(A))
TASK 49-00-81-810-874-A
Fumes in the Cabin/Oil Smoke at the APU Exhaust (131-9(A))
1. Possible Causes
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Referenced Information
3. Fault Confirmation
Subtask 49-00-81-710-196-A ** ON A/C NOT FOR ALL
Subtask 49-00-81-810-136-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:38:47 UTC
Fumes in the Cabin/Oil Smoke at the APU Exhaust (131-9(A))
1. Possible Causes
plumbing/tubing - APU component interfaces
- OIL COOLER
- OIL PUMP ASSY
- GEN-APU [8XS]
- FUEL CONTROL UNIT P19
- INLET GUIDE-VANE ACTUATOR P21
- oil contamination inside cooling-fan discharge duct
- unwanted material on the surfaces of the air intake system components
- the oil level in the oil reservoir is above the FULL mark on the oil sight glas
- APU [4005KM]
OIL COOLER (8079KM) OIL PUMP ASSY (8080KM) FUEL CONTROL UNIT (8022KM) INLET GUIDE-VANE ACTUATOR (8014KM) - flexible seals on the air intake system
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | LIGHT SOURCE - ULTRA-VIOLET |
| REFERENCE | DESIGNATION |
|---|---|
| No specific | overflow drain tool |
| REFERENCE | DESIGNATION |
|---|---|
| AMM 12-33-21-618-001 | Pre-conditioning through the LP Ground Connection |
| AMM 21-00-00-100-001 | Cleaning of Special Components in the Environmental Control System (ECS) |
| AMM 21-00-00-615-001 | Decontamination of the Environmental Control System (ECS) when the Temperature is below 24 deg.C (APU) |
| AMM 21-00-00-615-002 | Decontamination of the Environmental Control System (ECS) when the Temperature is above 24 deg.C (APU) |
| AMM 24-23-51-000-001 | Removal of the APU Generator |
| AMM 24-23-51-400-001 | Installation of the APU Generator |
| AMM 49-00-00-710-010 | Operational Test of the APU |
| AMM 49-11-11-000-004 | Removal of the Power Plant (APU) (131-9(A)) |
| AMM 49-11-11-400-004 | Installation of the Power Plant (APU) (131-9(A)) |
| AMM 49-16-00-100-005 | Cleaning of the APU Air Intake (131-9(A)) |
| AMM 49-16-00-200-002 | Detailed Inspection of APU Air Intake, Diffuser Elbow, Seals and Felt Metal (131-9(A)) |
| AMM 49-23-51-000-004 | Removal of the Inlet Guide Vane - Actuator (131-9(A)) |
| AMM 49-23-51-400-004 | Installation of the Inlet Guide Vane - Actuator (131-9(A)) |
| AMM 49-32-11-000-003 | Removal of the Fuel Control Unit (FCU) (131-9(A)) |
| AMM 49-32-11-400-003 | Installation of the Fuel Control Unit (FCU) (131-9(A)) |
| AMM 49-51-51-000-004 | Removal of the Load Control Valve (131-9(A)) |
| AMM 49-51-51-400-004 | Installation of the Load Control Valve (131-9(A)) |
| AMM 49-52-51-000-002 | Removal of the Cooling Fan (131-9(A)) |
| AMM 49-52-51-400-002 | Installation of the Cooling Fan (131-9(A)) |
| AMM 49-90-00-600-007 | Check Oil Level and Replenish (131-9(A)) |
| AMM 49-91-41-200-002 | Remove and Discard Oil Filter Elements (131-9(A)) |
| AMM 49-91-42-200-004 | Inspection of the Metal Chip Detector (131-9(A)) |
| AMM 49-91-42-400-003 | Installation of the Drain Plug (131-9(A)) |
| AMM 49-91-44-000-004 | Removal of the Oil Cooler (131-9(A)) |
| AMM 49-91-44-000-802 | Removal of the Oil-Cooler Transfer Tubes (131-9(A)) |
| AMM 49-91-44-400-004 | Installation of the Oil Cooler (131-9(A)) |
| AMM 49-91-44-400-802 | Installation of the Oil-Cooler Transfer Tubes (131-9(A)) |
| AMM 49-91-45-000-003 | Removal of Oil Lube Module (131-9(A)) |
| AMM 49-91-45-400-003 | Installation of Oil Lube Module (131-9(A)) |
| AMM 49-91-49-000-003 | Removal of De-Oil Solenoid (131-9(A)) |
| AMM 49-91-49-400-003 | Installation of De-Oil Solenoid (131-9(A)) |
| AMM 49-93-16-000-003 | Removal of Oil Level Switch (131-9(A)) |
| AMM 49-93-16-400-003 | Installation of Oil Level Switch (131-9(A)) |
Subtask 49-00-81-710-196-A ** ON A/C NOT FOR ALL
A. If it is necessary to confirm the fault:
4. Fault Isolation- do the pre-conditioning with the APU AMM 12-33-21-618-001 and
- do a check in the cabin for fumes.
NOTE: Before you do the pre-conditioning with the APU, make sure that the external area around of the APU air intake and the diverter is clean.
Make sure that no exhaust gases from main engines and/or ground support equipment go into the APU air intake during the pre-conditioning.
Make sure that no exhaust gases from main engines and/or ground support equipment go into the APU air intake during the pre-conditioning.
NOTE: If the APU did operate during fluid de-icing operations, it can be that the APU Inlet and the APU compressors are contaminated.
Then do the cleaning and testing as given in the Para. 4.C. before you do the fault confirmation.
Then do the cleaning and testing as given in the Para. 4.C. before you do the fault confirmation.
Subtask 49-00-81-810-136-A ** ON A/C NOT FOR ALL
A. If you smell fumes in the cabin during the pre-conditioning with the APU and there is no oil smoke on the exhaust during the operation of the APU.
If there is oil contamination inside cooling-fan discharge duct and the inside of the APU inlet plenum is clean:
Subtask 49-00-81-810-136-B ** ON A/C NOT FOR ALL NOTE: Do the cleaning and testing as given in the Para. 4.B. after each repair step during the fault isolation.
If you fail to do this, the fault may continues.
If you fail to do this, the fault may continues.
- examine the outer and inner surfaces and the flexible seals on the air intake diffuser and elbow and make sure that they are clean,
- examine the surfaces of the air intake diverter and the air inlet duct and make sure that they are clean,
- examine the surfaces and the flexible seals of the APU access doors and make sure that they are clean.
NOTE: Do the checks with a LIGHT SOURCE - ULTRA-VIOLET.
Make sure that there is no contamination of oil, fuel, grease, other unwanted material and/or remaining signs of contamination.
(1) If there is contamination of oil, fuel or grease on the outer and/or inner surfaces of the air intake system components and/or the APU access doors: Make sure that there is no contamination of oil, fuel, grease, other unwanted material and/or remaining signs of contamination.
- identify the type of contamination and the area of the source,
- examine the
plumbing/tubing and the APU component interfaces in that area for leaks.
NOTE: If necessary, do the checks with a LIGHT SOURCE - ULTRA-VIOLET.
Do the check very carefully on the:
Do the check very carefully on the:
- OIL COOLER ,
- OIL PUMP ASSY ,
- GEN-APU [8XS] ,
- FUEL CONTROL UNIT P19 ,
- INLET GUIDE-VANE ACTUATOR P21 .
NOTE: If you cannot identify the leak(s) when the APU does not operate:
(a) If there is presence of oil at the Load Compressor Cavity drain. - start and operate the APU with no bleed air supply and no APU generator load AMM 49-00-00-710-010,
- let the APU operate for 15 minutes for thermal stabilazation,
- do a leak check on the APU with a black light lamp,
- do the APU shutdown AMM 49-00-00-710-010,
- immediately after the APU has stopped, examine the APU carefully with a black light lamp to identify the leak(s).
- replace the APU AMM 49-11-11-000-004 and AMM 49-11-11-400-004.
- do the repair and replace the tubes, the connectors and the seals as necessary.
- replace the seals and/or the COOLING FAN AMM 49-52-51-000-002 and AMM 49-52-51-400-002 as necessary.
- Replace the OIL COOLER AMM 49-91-44-000-004 AMM 49-91-44-400-004 and/or the packings of the oil lines connectors and/or the oil lines as necessary AMM 49-91-44-000-802 AMM 49-91-44-400-802.
If there is oil contamination inside cooling-fan discharge duct and the inside of the APU inlet plenum is clean:
- do a further inspection of the cooling fan.
- replace the seals and or the OIL PUMP ASSY as necessary AMM 49-91-45-000-003 and AMM 49-91-45-400-003.
- replace the SEALING PLATE and/or the GEN-APU [8XS]
AMM 24-23-51-000-001 and AMM 24-23-51-400-001, as necessary.
- replace the packing of the related filter housing AMM 49-91-41-200-002.
- replace the packing of the magnetic chip detector AMM 49-91-42-200-004.
- replace the packing of the drain plug housing AMM 49-91-42-400-003.
- replace the packing of the oil level switch AMM 49-93-16-000-003 and AMM 49-93-16-400-003.
- replace the packing of the de-oil solenoid AMM 49-91-49-000-003 and AMM 49-91-49-400-003.
- replace the seals and or the FUEL CONTROL UNIT P19 as necessary AMM 49-32-11-000-003 and AMM 49-32-11-400-003.
- replace the seals and/or the fuel lines to the actuator and/or the INLET GUIDE VANE-ACTUATOR P21 as necessary AMM 49-23-51-000-004 and AMM 49-23-51-400-004.
- identify the material and its source,
- if the oil level in the oil reservoir is above the FULL mark on the oil sight glas , correct it with the overflow drain tool AMM 49-90-00-600-007.
NOTE: If the APU oil reservoir was filled above the FULL mark on the oil sight glass:
During APU operation the oil expands which could create an over-filled condition, resulting in leakage and possible oil smell in the cabin.
During APU operation the oil expands which could create an over-filled condition, resulting in leakage and possible oil smell in the cabin.
- remove the APU Bleed-Air Duct Elbow AMM 49-11-11-000-004,
- remove the Load Control Valve P12 AMM 49-51-51-000-004.
- examine the removed components with a LIGHT SOURCE - ULTRA-VIOLET and make sure that you do not find signs of contamination.
- clean the APU Bleed-Air Duct Elbow and install it AMM 49-11-11-400-004,
- clean the Load Control Valve P12 and install it AMM 49-51-51-400-004.
- replace the APU [4005KM] AMM 49-11-11-000-004 and AMM 49-11-11-400-004.
A. If you smell fumes in the cabin during the pre-conditioning with the APU and there is no oil smoke on the exhaust during the operation of the APU.
If there is oil contamination inside cooling-fan discharge duct and the inside of the APU inlet plenum is clean:
Subtask 49-00-81-710-197-A ** ON A/C NOT FOR ALL NOTE: Do the cleaning and testing as given in the Para. 4.B. after each repair step during the fault isolation.
If you fail to do this, the fault may continues.
If you fail to do this, the fault may continues.
- examine the outer and inner surfaces and the flexible seals on the air intake diffuser and elbow and make sure that they are clean,
- examine the surfaces of the air intake diverter and the air inlet duct and make sure that they are clean,
- examine the surfaces and the flexible seals of the APU access doors and make sure that they are clean.
NOTE: Do the checks with a LIGHT SOURCE - ULTRA-VIOLET.
Make sure that there is no contamination of oil, fuel, grease, other unwanted material and/or remaining signs of contamination.
(1) If there is contamination of oil, fuel or grease on the outer and/or inner surfaces of the air intake system components and/or the APU access doors: Make sure that there is no contamination of oil, fuel, grease, other unwanted material and/or remaining signs of contamination.
- identify the type of contamination and the area of the source,
- examine the
plumbing/tubing and the APU component interfaces in that area for leaks.
NOTE: If necessary, do the checks with a LIGHT SOURCE - ULTRA-VIOLET.
Do the check very carefully on the:
Do the check very carefully on the:
OIL COOLER (8079KM) ,OIL PUMP ASSY (8080KM) ,- GEN-APU [8XS] ,
FUEL CONTROL UNIT (8022KM) ,INLET GUIDE-VANE ACTUATOR (8014KM) .
NOTE: If you cannot identify the leak(s) when the APU does not operate:
(a) If there is a presence of oil at the Load Compressor Cavity drain. - start and operate the APU with no bleed air supply and no APU generator load AMM 49-00-00-710-010,
- let the APU operate for 15 minutes for thermal stabilazation,
- do a leak check on the APU with a black light lamp,
- do the APU shutdown AMM 49-00-00-710-010,
- immediately after the APU has stopped, examine the APU carefully with a black light lamp to identify the leak(s).
- Replace the APU AMM 49-11-11-000-004 and AMM 49-11-11-400-004.
- do the repair and replace the tubes, the connectors and the seals as necessary.
- replace the seals and/or the COOLING FAN (8053KM) AMM 49-52-51-000-002 and AMM 49-52-51-400-002 as necessary.
- Replace the OIL COOLER (8079KM) AMM 49-91-44-000-004 AMM 49-91-44-400-004 and/or the packings of the oil lines connectors and/or the oil lines as necessary AMM 49-91-44-000-802 AMM 49-91-44-400-802.
If there is oil contamination inside cooling-fan discharge duct and the inside of the APU inlet plenum is clean:
- do a further inspection of the cooling fan.
- replace the seals and or the OIL PUMP ASSY as necessary AMM 49-91-45-000-003 and AMM 49-91-45-400-003.
- replace the SEALING PLATE and/or the GEN-APU [8XS]
AMM 24-23-51-000-001 and AMM 24-23-51-400-001, as necessary.
- replace the packing of the related filter housing AMM 49-91-41-200-002.
- replace the packing of the magnetic chip detector AMM 49-91-42-200-004.
- replace the packing of the drain plug housing AMM 49-91-42-400-003.
- replace the packing of the oil level switch AMM 49-93-16-000-003 and AMM 49-93-16-400-003.
- replace the packing of the de-oil solenoid AMM 49-91-49-000-003 and AMM 49-91-49-400-003.
- replace the seals and or the FUEL CONTROL UNIT (8022KM) as necessary AMM 49-32-11-000-003 and AMM 49-32-11-400-003.
- replace the seals and/or the fuel lines to the actuator and/or the INLET GUIDE VANE-ACTUATOR (8014KM) as necessary AMM 49-23-51-000-004 and AMM 49-23-51-400-004.
- identify the material and its source,
- if the oil level in the oil reservoir is above the FULL mark on the oil sight glas , correct it with the overflow drain tool AMM 49-90-00-600-007.
NOTE: If the APU oil reservoir was filled above the FULL mark on the oil sight glass:
During APU operation the oil expands which could create an over-filled condition, resulting in leakage and possible oil smell in the cabin.
During APU operation the oil expands which could create an over-filled condition, resulting in leakage and possible oil smell in the cabin.
- remove the APU Bleed-Air Duct Elbow AMM 49-11-11-000-004,
- remove the Load Control Valve (8050KM) AMM 49-51-51-000-004.
- examine the removed components with a LIGHT SOURCE - ULTRA-VIOLET and make sure that you do not find signs of contamination.
- clean the APU Bleed-Air Duct Elbow and install it AMM 49-11-11-400-004,
- clean the Load Control Valve (8050KM) and install it AMM 49-51-51-400-004.
- replace the APU [4005KM] AMM 49-11-11-000-004 and AMM 49-11-11-400-004.
B. Cleaning and Testing
(1) If an external leak was identified on the APU:
(2) If dirty, clean the APU compartment.
(3) If dirty, clean the air intake diverter, the air inlet duct and the air intake diffuser and elbow AMM 49-16-00-100-005.
(4) Do a check and make sure that the flexible seals on the air intake system are in correct condition AMM 49-16-00-200-002 and clean.
(5) Clean the APU bleed air duct, the pneumatic ducts of the aircraft and the environmental control system AMM 21-00-00-615-001 or AMM 21-00-00-615-002 and AMM 21-00-00-100-001.
(6) Do the pre-conditioning with the APU AMM 12-33-21-618-001 and make sure that you do not smell fumes in the cabin and/or there is no oil smoke at the APU exhaust.
(7) Do a leak check and make sure that there is no fuel leak and/or no oil leak on the APU and/or the APU generator.
(1) If an external leak was identified on the APU:
- do the repair,
- clean the area,
- start and operate the APU with no bleed air supply and no APU generator load AMM 49-00-00-710-010,
- let the APU operate 15 minutes for thermal stabilization,
- do a leak check on the APU with a black light lamp,
- do the APU shutdown AMM 49-00-00-710-010,
- immediately after the APU has stopped, examine the area carefully and make sure that there is no leak,
- if there is a leak (the repair was not succesful), do the repair and/or replace as necessary.
- if there is no leak (the repair was successful), continue as given subsequent.
(2) If dirty, clean the APU compartment.
(3) If dirty, clean the air intake diverter, the air inlet duct and the air intake diffuser and elbow AMM 49-16-00-100-005.
(4) Do a check and make sure that the flexible seals on the air intake system are in correct condition AMM 49-16-00-200-002 and clean.
(5) Clean the APU bleed air duct, the pneumatic ducts of the aircraft and the environmental control system AMM 21-00-00-615-001 or AMM 21-00-00-615-002 and AMM 21-00-00-100-001.
(6) Do the pre-conditioning with the APU AMM 12-33-21-618-001 and make sure that you do not smell fumes in the cabin and/or there is no oil smoke at the APU exhaust.
(7) Do a leak check and make sure that there is no fuel leak and/or no oil leak on the APU and/or the APU generator.
NOTE: Do the leak check with a LIGHT SOURCE - ULTRA-VIOLET.