W DOC AIRBUS | AMM A320F

Starter Inspection for a probably FOD (Foreign Object Damage) [CFMI]


TASK 80-11-10-210-002-A
Starter Inspection for a probably FOD (Foreign Object Damage)


FIN: 1000EM1 ** ON A/C NOT FOR ALL
FIN: 1000EM2 ** ON A/C NOT FOR ALL
1. Reason for the Job
This check must be done if a FOD (Foreign Object Damage) is probably found:
  • Damages can cause a slow start or no start
  • This check is also necessary if there is an indication of IP Bleed Check Valve damage (cracks, missing segments or wear out of limits)
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
WARNING NOTICE(S)
No specific
Torque wrench: range to between 80 and 70 lbf.in (0.90 and 0.79 m.daN ) T
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.CP2101)
graphite grease
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [1000EM1] (ENGINE-1)
437AL, 438AR
FOR [1000EM2] (ENGINE-2)
447AL, 448AR
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 36-11-41-200-001-A
Check of the IP Bleed Check Valve for Condition
TASK 36-11-49-200-041-A
Visual Inspection of the Pneumatic System Hoses, Tubes and Ducts
TASK 71-13-00-010-040-A
Opening of the Fan Cowl Doors
TASK 71-13-00-410-040-A
Closing of the Fan Cowl Doors
TASK 80-11-10-000-001-A
Removal of the Pneumatic Starter
TASK 80-11-10-400-001-A
Installation of the Pneumatic Starter
TASK 80-13-42-000-040-A
Removal of the Lower Starter Duct
TASK 80-13-42-400-040-A
Installation of the Lower Starter Duct
3. Job Set-up
Subtask 80-11-10-941-054-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) On the center pedestal, on the ENG panel 115VU:
     (a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
   (2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
   (3) On the overhead maintenance panel 50VU:
     (a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 80-11-10-010-056-A ** ON A/C NOT FOR ALL
B. Open the fan cowl doors: (Ref. AMM TASK 71-13-00-010-040)
   (1) FOR [1000EM1] (ENGINE-1)
437AL 438AR
   (2) FOR [1000EM2] (ENGINE-2)
447AL 448AR
4. Procedure
Subtask 80-11-10-210-054-A ** ON A/C NOT FOR ALL
A. Inspect Starter for FOD.
   (1) Remove the V-clamp (70) which attaches the air supply duct (80) to the pneumatic starter (60) to get access to the starter, if necessary, remove the lower starter duct (Ref. AMM TASK 80-13-42-000-040).
   (2) Introduces a mirror and a light in the starter exhaust, inspect the diffuser vane for any sign of FOD :
  • scratches, dents, missing segments.
  • signs, impacts.
   (3) If any of the above signs is found:
   (4) If you had removed the lower starter duct, install it (Ref. AMM TASK 80-13-42-400-040).
   (5) If there is no sign of FOD, put the V-clamp (70) on the air supply duct (80) in position on the starter air inlet orifice. Lubricate the threads of clamp nut with graphite grease (Material No.CP2101) . Install nut and TORQUE to between 80 and 70 lbf.in (0.90 and 0.79 m.daN ) T .
5. Close-up
Subtask 80-11-10-410-054-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021] 2026.04.01 12:38:20 UTC