Removal of the Low Oil Pressure (LOP) Switch [PW11]
TASK 79-33-25-000-801-A
Removal of the Low Oil Pressure (LOP) Switch
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 79-33-25-941-050-A ** ON A/C NOT FOR ALL
Subtask 79-33-25-865-051-A ** ON A/C NOT FOR ALL
Subtask 79-33-25-010-050-A ** ON A/C NOT FOR ALL
Subtask 79-33-25-020-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 13:14:38 UTC
Removal of the Low Oil Pressure (LOP) Switch
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE AND THE ADJACENT COMPONENTS AFTER ENGINE SHUTDOWN. THE ENGINE, THE ENGINE OIL AND THE ADJACENT COMPONENTS CAN STAY HOT FOR A LONG TIME. IF YOU DO NOT OBEY THIS INSTRUCTION, INJURY CAN OCCUR.
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
CAUTION:
DO NOT LET ENGINE FUEL, OIL OR HYDRAULIC FLUID SPILL ON THE ENGINE. YOU MUST IMMEDIATELY REMOVE UNWANTED FUEL, OIL OR HYDRAULIC FLUID WITH A CLOTH. FUEL, OIL OR HYDRAULIC FLUID CAN CAUSE DAMAGE TO SOME ENGINE PARTS.
CAUTION:
INSTALL PROTECTION COVERS ON ALL THE OPENINGS IMMEDIATELY TO PREVENT DAMAGE TO THE ENGINE.
FIN: 4080KS ** ON A/C NOT FOR ALL
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | COVER - PROTECTION |
| No specific | 1 | PLIERS - JAWED, SOFT |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.P05-005) | lint-free cotton cloth |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1) | |
| 437AL, 438AR, 451AL | |
| FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2) | |
| 447AL, 448AR, 461AL | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-00-00-860-832-A | Procedure to Prevent Engine Motoring and to Stop the Electrical Supply to the EEC |
| TASK 71-13-00-010-802-A | Opening of the Fan Cowl Doors |
| TASK 78-30-00-040-805-A | Deactivation of the Thrust Reverser System for Ground Maintenance |
| TASK 78-36-00-010-802-A | Opening of the Thrust Reverser Cowl-Doors |
Subtask 79-33-25-941-050-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) Do the procedure to prevent engine motoring and to stop the electrical supply to the Electronic Engine Control (EEC)
(Ref. AMM TASK 71-00-00-860-832)
Subtask 79-33-25-865-050-A ** ON A/C NOT FOR ALL (1) Do the procedure to prevent engine motoring and to stop the electrical supply to the Electronic Engine Control (EEC)
(Ref. AMM TASK 71-00-00-860-832)
WARNING:
OPEN CIRCUIT BREAKERS 2KS1 AND 2KS2 AFTER YOU OPEN THE IGNITION CIRCUIT BREAKERS. IF YOU DO NOT, THE CONTINUOUS IGNITION SYSTEM WILL BE ACTIVATED.
B. Open, safety and tag this(these) circuit breaker(s):| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | ANTI ICE/PROBES/AOA/1 | 4DA1 | D04 |
| 49VU | ANTI ICE/PROBES/PITOT/1 | 3DA1 | D02 |
| 122VU | ANTI ICE/PROBES/2/TAT | 1DA2 | Y15 |
| 122VU | ANTI ICE/PROBES/2/PITOT | 3DA2 | Y14 |
| 122VU | ANTI ICE/PROBES/2/AOA | 4DA2 | Y13 |
| 122VU | ANTI ICE/PROBES/2/STATIC | 5DA2 | Y11 |
| 122VU | ANTI ICE/PROBES/3/PITOT | 3DA3 | Z16 |
| 122VU | ANTI ICE/PROBES/3/AOA | 4DA3 | Z15 |
| 122VU | ANTI ICE/PROBES/3/STATIC | 5DA3 | Z14 |
| 122VU | ANTI ICE/PROBES/1/STATIC | 5DA1 | Z13 |
| 122VU | ANTI ICE/PROBES/1/TAT | 1DA1 | Z12 |
| FOR FIN: 1KS1 (EIU1) | |||
| 49VU | ENGINE/1/FADEC A/AND EIU 1 | 2KS1 | A04 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | ENGINE/ENG1/FADEC B/AND EIU 1 | 4KS1 | R41 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | ENGINE/ENG1/FADEC B/AND EIU 1 | 4KS1 | R40 |
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 1KS2 (EIU2) | |||
| 49VU | ENGINE/2/FADEC A/AND EIU 2 | 2KS2 | A05 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | ENGINE/ENG2/FADEC B/AND EIU2 | 4KS2 | Q40 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | ENGINE/ENG2/FADEC B/AND EIU2 | 4KS2 | R41 |
WARNING:
MAKE SURE THAT THE PROBE HEATER AND WINDOW HEATER CIRCUIT-BREAKERS ARE OPEN BEFORE YOU OPEN THE PHC AND WHC CIRCUIT BREAKERS. IF YOU DO NOT OBEY THIS SEQUENCE:
C. Open, safety and tag this(these) circuit breaker(s):- THE PROBES WILL BECOME TOO HOT.
- THIS CAN CAUSE INJURY TO MAINTENANCE PERSONNEL AND/OR DAMAGE TO EQUIPMENT.
| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | ANTI ICE/PROBES/PHC/1 | 2DA1 | D03 |
| 122VU | ANTI ICE/WHC/2 | 5DG2 | W13 |
| 122VU | ANTI ICE/WHC/1 | 5DG1 | X13 |
| 122VU | ANTI ICE/PROBES/PHC/3 | 2DA3 | Y16 |
| 122VU | ANTI ICE/PROBES/PHC/2 | 2DA2 | Y12 |
D. Get Access
(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL 448AR
Subtask 79-33-25-040-050-A ** ON A/C NOT FOR ALL (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL 448AR
E. Deactivation of the Thrust Reverser for Maintenance
Subtask 79-33-25-010-051-A ** ON A/C NOT FOR ALL WARNING:
MAKE SURE THAT YOU DO THE DEACTIVATION OF THE THRUST REVERSER BEFORE YOU DO MAINTENANCE WORK ON OR AROUND THE THRUST REVERSER.
IF YOU DO NOT DO THIS PROCEDURE, THERE IS A RISK OF UNWANTED OPERATION AND THUS OF INJURY TO PERSONS AND DAMAGE TO EQUIPMENT.
(1) Do the deactivation of the thrust reverser system for maintenance (Ref. AMM TASK 78-30-00-040-805). F. Get Access
(1) Open the left thrust-reverser cowl-doors (Ref. AMM TASK 78-36-00-010-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
451AL
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
461AL
4. Procedure(1) Open the left thrust-reverser cowl-doors (Ref. AMM TASK 78-36-00-010-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
451AL
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
461AL
Subtask 79-33-25-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Low Oil Pressure (LOP) Switch
(1) Find the switch (1) located approximately at the 9 o'clock position attached to the oil control manifold to the left of the main gearbox.
(2) Remove the switch (1) as follows:
(a) Disconnect the wiring harness connector (P70) from the switch (1) with the PLIERS - JAWED, SOFT.
(b) Put a lint-free cotton cloth (Material No.P05-005) below the switch (1) to absorb any remaining oil.
(c) Remove the two bolts (2) that attach the switch (1) to the oil manifold.
(d) Remove the switch (1) from the oil manifold.
(e) Discard the packing (3) from the switch (1).
(3) Make sure that you install all of the necessary COVER - PROTECTION to prevent engine damage.
(1) Find the switch (1) located approximately at the 9 o'clock position attached to the oil control manifold to the left of the main gearbox.
(2) Remove the switch (1) as follows:
(a) Disconnect the wiring harness connector (P70) from the switch (1) with the PLIERS - JAWED, SOFT.
(b) Put a lint-free cotton cloth (Material No.P05-005) below the switch (1) to absorb any remaining oil.
(c) Remove the two bolts (2) that attach the switch (1) to the oil manifold.
(d) Remove the switch (1) from the oil manifold.
(e) Discard the packing (3) from the switch (1).
(3) Make sure that you install all of the necessary COVER - PROTECTION to prevent engine damage.
Low Oil Pressure (LOP) Switch