Procedure to Prevent Engine Motoring and to Stop the Electrical Supply to the EEC [PW11]
TASK 71-00-00-860-832-A
Procedure to Prevent Engine Motoring and to Stop the Electrical Supply to the EEC
1. Reason for the Job
To make sure that the engine will not be motored and the EEC electrically supplied during other maintenance operation.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
3. Job Set-up
Subtask 71-00-00-941-166-A ** ON A/C NOT FOR ALL
Subtask 71-00-00-941-167-E ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 05:44:50 UTC
Procedure to Prevent Engine Motoring and to Stop the Electrical Supply to the EEC
1. Reason for the Job
To make sure that the engine will not be motored and the EEC electrically supplied during other maintenance operation.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | WARNING NOTICE(S) |
Subtask 71-00-00-941-166-A ** ON A/C NOT FOR ALL
A. Not Applicable
4. ProcedureSubtask 71-00-00-941-167-E ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) Do as follows:
(a) On the center pedestal, on the ENG panel 115VU:
1 Make sure that the ENG/MODE selector switch is in the NORM position.
2 Make sure that the ENG/MASTER 1(2) control switch is set to OFF position before the start of this procedure.
3 On 22VU, make sure that the DUAL COOLING control switch is set to OFF position before the start of this procedure.
4 Put a WARNING NOTICE(S) in position to tell persons not to operate the ENG/MODE selector switch, the ENG/MASTER 1(2) control switch and the DUAL COOLING control switch.
(b) On the ENG section of maintenance panel 50VU:
1 Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
2 Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
(1) Do as follows:
(a) On the center pedestal, on the ENG panel 115VU:
1 Make sure that the ENG/MODE selector switch is in the NORM position.
2 Make sure that the ENG/MASTER 1(2) control switch is set to OFF position before the start of this procedure.
3 On 22VU, make sure that the DUAL COOLING control switch is set to OFF position before the start of this procedure.
4 Put a WARNING NOTICE(S) in position to tell persons not to operate the ENG/MODE selector switch, the ENG/MASTER 1(2) control switch and the DUAL COOLING control switch.
(b) On the ENG section of maintenance panel 50VU:
1 Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
2 Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
NOTE: In the aircraft configuration defined in paragraph 4.A. above, when you open the fan cowl doors, the EIU automatically cuts the aircraft power supply to the EEC.