W DOC AIRBUS | AMM A320F

Removal of the Main Oil Pressure (MOP) Sensor [PW11]


TASK 79-33-21-000-801-A
Removal of the Main Oil Pressure (MOP) Sensor


WARNING: BE CAREFUL WHEN YOU DO WORK ON THE ENGINE AFTER SHUTDOWN. THE ENGINE CAN STAY HOT FOR A LONG TIME. IF YOU DO NOT OBEY THIS INSTRUCTION, INJURY CAN OCCUR.
WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
CAUTION: DO NOT LET FUEL OR OIL FALL ON THE ENGINE. YOU MUST IMMEDIATELY REMOVE UNWANTED FUEL OR OIL WITH A CLOTH. THE FUEL OR OIL CAN CAUSE DAMAGE TO SOME ENGINE PARTS.
ZONE: 400
FIN: 4071KS ** ON A/C NOT FOR ALL
1. Reason for the Job
Use this procedure to remove the MOP sensor.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
CONTAINER 20L (5 USGAL)
No specific
AR
COVER - PROTECTION
No specific
1
PLIERS - JAWED, SOFT
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.P05-005)
lint-free cotton cloth
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
400
POWER PLANT, NACELLES AND PYLONS
FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL, 438AR, 451AL
FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL, 448AR, 461AL
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 71-00-00-860-832-A
Procedure to Prevent Engine Motoring and to Stop the Electrical Supply to the EEC
TASK 71-13-00-010-802-A
Opening of the Fan Cowl Doors
TASK 78-30-00-040-805-A
Deactivation of the Thrust Reverser System for Ground Maintenance
TASK 78-36-00-010-802-A
Opening of the Thrust Reverser Cowl-Doors
3. Job Set-up
Subtask 79-33-21-941-050-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) Do the procedure to prevent engine motoring and to stop the electrical supply to the Electronic Engine Control (EEC)
(Ref. AMM TASK 71-00-00-860-832).
Subtask 79-33-21-010-050-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-802):
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL 438AR
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL 448AR
Subtask 79-33-21-040-050-A ** ON A/C NOT FOR ALL
C. Deactivation of the Thrust Reverser for Maintenance
WARNING: YOU MUST DEACTIVATE THE THRUST REVERSER BEFORE YOU DO WORK ON OR AROUND IT. IF YOU DO NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE AN INJURY AND/OR DAMAGE.
   (1) Do the deactivation of the thrust reverser system for maintenance (Ref. AMM TASK 78-30-00-040-805).
Subtask 79-33-21-010-051-A ** ON A/C NOT FOR ALL
D. Get Access
   (1) Open the left thrust-reverser cowl-door (Ref. AMM TASK 78-36-00-010-802):
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
451AL
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
461AL
4. Procedure
Subtask 79-33-21-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Main Oil Pressure (MOP) Sensor
CAUTION: WIPE CLEAN ALL PARTS AND TOOLS AS NECESSARY TO REMOVE UNWANTED DEBRIS AND PREVENT DAMAGE TO THE ENGINE.
   (1) Find the MOP sensor (1) attached to the front of the oil control manifold to the left of the main gearbox at the 9 o'clock position.
   (2) Put the CONTAINER 20L (5 USGAL) under the sensor (1).
   (3) Remove the MOP sensor (1) as follows:
     (a) Disconnect the WC10 core harness (4011KS) connector P38 from the sensor (1) with the PLIERS - JAWED, SOFT.
     (b) Put a lint-free cotton cloth (Material No.P05-005) below the sensor (1) to absorb any remaining oil.
     (c) Loosen the two bolts (2).
     (d) Turn the sensor (1) to disengage the two bolts (2).
     (e) Remove the sensor (1) from the oil manifold.
     (f) Discard the packing (3).
   (4) Installation of the protection covers.
CAUTION: INSTALL PROTECTION COVERS ON ALL THE OPENINGS IMMEDIATELY TO PREVENT DAMAGE TO THE ENGINE.
     (a) Make sure that you install COVER - PROTECTION as necessary to prevent damage to the engine
[Rev.10 from 2021] 2026.04.01 13:14:38 UTC