W DOC AIRBUS | AMM A320F

Removal of the Variable Oil Reduction Valve (VORV) [PW11]


TASK 79-21-15-000-801-A
Removal of the Variable Oil Reduction Valve (VORV)


WARNING: BE CAREFUL WHEN YOU DO WORK ON THE ENGINE AND THE ADJACENT COMPONENTS AFTER ENGINE SHUTDOWN. THE ENGINE, THE ENGINE OIL AND THE ADJACENT COMPONENTS CAN STAY HOT FOR A LONG TIME. IF YOU DO NOT OBEY THIS INSTRUCTION, INJURY CAN OCCUR.
WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
FIN: 4069KS ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
COVER - PROTECTION
No specific
1
PLIERS - JAWED, SOFT
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.P05-005)
lint-free cotton cloth
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL, 438AR, 451AL
FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL, 448AR, 461AL
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 71-00-00-860-832-A
Procedure to Prevent Engine Motoring and to Stop the Electrical Supply to the EEC
TASK 71-13-00-010-802-A
Opening of the Fan Cowl Doors
TASK 78-30-00-040-805-A
Deactivation of the Thrust Reverser System for Ground Maintenance
TASK 78-36-00-010-802-A
Opening of the Thrust Reverser Cowl-Doors
TASK 79-21-15-400-801-A
Installation of the Variable Oil Reduction Valve (VORV)
3. Job Set-up
Subtask 79-21-15-941-050-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) Do the procedure to prevent engine motoring and to stop the electrical supply to the Electronic Engine Control (EEC)
(Ref. AMM TASK 71-00-00-860-832).
Subtask 79-21-15-010-050-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-802):
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL 438AR
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL 448AR
Subtask 79-21-15-040-050-A ** ON A/C NOT FOR ALL
C. Deactivation of the Thrust Reverser for Maintenance
WARNING: YOU MUST DEACTIVATE THE THRUST REVERSER BEFORE YOU DO WORK ON OR AROUND IT. IF YOU DO NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE AN INJURY AND/OR DAMAGE.
   (1) Do the deactivation of the thrust reverser system for maintenance (Ref. AMM TASK 78-30-00-040-805).
Subtask 79-21-15-010-051-A ** ON A/C NOT FOR ALL
D. Get Access
   (1) Open the left thrust reverser cowl-doors (Ref. AMM TASK 78-36-00-010-802):
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
451AL
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
461AL
4. Procedure
Subtask 79-21-15-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the VORV
   (1) Find the VORV (1) attached to the Oil Control Manifold (OCM) on the left of the engine at the nine o'clock position.
   (2) Disconnect the wiring harness (W03) connector (P54) from the VORV (1) with the PLIERS - JAWED, SOFT.
   (3) Remove the VORV (1) from the OCM as follows:
     (a) Put a lint-free cotton cloth (Material No.P05-005) below the VORV (1) to absorb any remaining oil.
     (b) Remove the five bolts (12) and washers (13).
     (c) Remove the VORV (1) from the manifold.
     (d) Remove the gasket (11) from the manifold.
NOTE: The gasket (11) may be reused later (Ref. AMM TASK 79-21-15-400-801).
   (4) Installation of the protection covers
CAUTION: INSTALL PROTECTION COVERS ON ALL THE OPENINGS IMMEDIATELY TO PREVENT DAMAGE TO THE ENGINE.
     (a) Make sure that you install COVER - PROTECTION as necessary to prevent damage to the engine.
[Rev.10 from 2021] 2026.04.01 13:03:23 UTC