Check of the Electrical Master Chip Detector (EMCD) for Particles [CFMB]
TASK 79-00-00-281-002-A
Check of the Electrical Master Chip Detector (EMCD) for Particles
1. Reason for the Job
Refer to the MPD TASK: 792000-C8
CHECK MASTER MAGNETIC CHIP DETECTOR FOR PARTICLES
(Inspection of the Electrical Master Chip Detector at scheduled intervals).
This inspection is required when the pop-out on the visual indicator is extended during operation.
This inspection is required when performing TSM Task 79-00-00-810-820/821 (Oil filter clogged). detection of particles and gives recommendations for Line Maintenance.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 79-00-00-941-055-A ** ON A/C NOT FOR ALL
Subtask 79-00-00-281-050-A ** ON A/C NOT FOR ALL
Subtask 79-00-00-410-055-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 03:38:51 UTC
Check of the Electrical Master Chip Detector (EMCD) for Particles
1. Reason for the Job
Refer to the MPD TASK: 792000-C8
CHECK MASTER MAGNETIC CHIP DETECTOR FOR PARTICLES
(Inspection of the Electrical Master Chip Detector at scheduled intervals).
This inspection is required when the pop-out on the visual indicator is extended during operation.
This inspection is required when performing TSM Task 79-00-00-810-820/821 (Oil filter clogged). detection of particles and gives recommendations for Line Maintenance.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-00-010-040-B | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-040-B | Closing of the Fan Cowl Doors |
| TASK 79-00-00-281-003-A | Check of FWD Sump, AFT Sump, AGB and TGB Scavenge Screens |
| TASK 79-00-00-281-004-A | Preparation of the Particles from the Electrical Master Chip Detector (EMCD) |
| TASK 79-00-00-281-006-A | Ground Run for Additional Particle Collection |
Subtask 79-00-00-941-055-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 79-00-00-010-055-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
B. Open the fan cowls doors: (Ref. AMM TASK 71-13-00-010-040)
(1) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(2) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
4. Procedure(1) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(2) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
Subtask 79-00-00-281-050-A ** ON A/C NOT FOR ALL
A. Inspection of the Electrical Master Chip Detector (EMCD)
(1) Inspect the Electrical Master Chip Detector (EMCD) (Ref. AMM TASK 79-00-00-281-004).
(a) If any findings, do a check of Fwd, Aft Sump, AGB and TGB Scavenge Screens (Ref. AMM TASK 79-00-00-281-003) for further troubleshooting.
(b) If any findings, perform Ground Run for Additional Particle Collection (Ref. AMM TASK 79-00-00-281-006) for further troubleshooting.
(c) If no findings, no further action.
5. Close-up(1) Inspect the Electrical Master Chip Detector (EMCD) (Ref. AMM TASK 79-00-00-281-004).
(a) If any findings, do a check of Fwd, Aft Sump, AGB and TGB Scavenge Screens (Ref. AMM TASK 79-00-00-281-003) for further troubleshooting.
(b) If any findings, perform Ground Run for Additional Particle Collection (Ref. AMM TASK 79-00-00-281-006) for further troubleshooting.
(c) If no findings, no further action.
Subtask 79-00-00-410-055-A ** ON A/C NOT FOR ALL
Position of the Electrical Master Magnetic Chip Detector for Particles