W DOC AIRBUS | AMM A320F

Visual Check of Clogging Indicator of the Hydraulic Isolation Valve Filter [IAE]


TASK 78-37-51-210-010-A
Visual Check of Clogging Indicator of the Hydraulic Isolation Valve Filter


FIN: 1000EM1 ** ON A/C NOT FOR ALL
FIN: 1000EM2 ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [1000EM1] (ENGINE-1)
437AL, 438AR
FOR [1000EM2] (ENGINE-2)
447AL, 448AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 71-13-00-010-010-A
Opening of the Fan Cowls 437AL(447AL),438AR(448AR)
TASK 71-13-00-410-010-A
Closing of the Fan Cowls 437AL(447AL),438AR(448AR)
TASK 78-31-00-710-041-A
Operational Test of the Thrust Reverser System with the CFDS
TASK 78-31-00-710-041-A-02
Operational test of the Thrust Reverser without the CFDS and Engine Running
TASK 78-37-51-600-010-A
Replacement of the Thrust Reverser Hydraulic Isolation Valve Filter
3. Job Set-up
Subtask 78-37-51-710-053-A ** ON A/C NOT FOR ALL
A. Do an operational test of the thrust reverser system with the CFDS (Ref. AMM TASK 78-31-00-710-041).
Subtask 78-37-51-941-056-A ** ON A/C NOT FOR ALL
B. Safety Precautions
   (1) On the center pedestal, on the ENG panel 115VU:
     (a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
   (2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
   (3) On the overhead maintenance panel 50VU:
     (a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 78-37-51-010-059-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) Open the fan cowls doors (Ref. AMM TASK 71-13-00-010-010):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
   (2) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
4. Procedure
Subtask 78-37-51-210-050-A ** ON A/C NOT FOR ALL
A. Visual check of the clogging indicator of the hydraulic isolation valve filter
   (1) Check that the red indicator is not extended. If it is extended replace the filter element (Ref. AMM TASK 78-37-51-600-010).
5. Close-up
Subtask 78-37-51-410-056-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Close the fan cowls doors (Ref. AMM TASK 71-13-00-410-010):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
   (2) Remove the WARNING NOTICE(S).
   (3) Remove the access platform(s).
[Rev.10 from 2021] 2026.04.01 03:30:14 UTC