Visual Check of Clogging Indicator of the Hydraulic Isolation Valve Filter [IAE]
TASK 78-37-51-210-010-A
Visual Check of Clogging Indicator of the Hydraulic Isolation Valve Filter
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 78-37-51-710-053-A ** ON A/C NOT FOR ALL
Subtask 78-37-51-210-050-A ** ON A/C NOT FOR ALL
Subtask 78-37-51-410-056-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 03:30:14 UTC
Visual Check of Clogging Indicator of the Hydraulic Isolation Valve Filter
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-00-010-010-A | Opening of the Fan Cowls 437AL(447AL),438AR(448AR) |
| TASK 71-13-00-410-010-A | Closing of the Fan Cowls 437AL(447AL),438AR(448AR) |
| TASK 78-31-00-710-041-A | Operational Test of the Thrust Reverser System with the CFDS |
| TASK 78-31-00-710-041-A-02 | Operational test of the Thrust Reverser without the CFDS and Engine Running |
| TASK 78-37-51-600-010-A | Replacement of the Thrust Reverser Hydraulic Isolation Valve Filter |
Subtask 78-37-51-710-053-A ** ON A/C NOT FOR ALL
A. Do an operational test of the thrust reverser system with the CFDS (Ref. AMM TASK 78-31-00-710-041).
Subtask 78-37-51-941-056-A ** ON A/C NOT FOR ALL B. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 78-37-51-010-059-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
C. Get Access
(1) Open the fan cowls doors (Ref. AMM TASK 71-13-00-010-010):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(2) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
4. Procedure(1) Open the fan cowls doors (Ref. AMM TASK 71-13-00-010-010):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(2) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
Subtask 78-37-51-210-050-A ** ON A/C NOT FOR ALL
A. Visual check of the clogging indicator of the hydraulic isolation valve filter
(1) Check that the red indicator is not extended. If it is extended replace the filter element (Ref. AMM TASK 78-37-51-600-010).
5. Close-up(1) Check that the red indicator is not extended. If it is extended replace the filter element (Ref. AMM TASK 78-37-51-600-010).
Subtask 78-37-51-410-056-A ** ON A/C NOT FOR ALL
Hydraulic Isolation Valve Filter Clogging Indicator