Deactivation of the Thrust Reverser Cowl Opening System [CFML]
TASK 78-36-00-040-816-A
Deactivation of the Thrust Reverser Cowl Opening System
CDL 78-01
Thrust Reverser Opening Actuator
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 78-36-00-941-081-A
Subtask 78-36-00-040-092-A
Subtask 78-36-00-440-081-A
[Rev.10 from 2021]
2026.04.01 03:36:44 UTC
Deactivation of the Thrust Reverser Cowl Opening System
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
ZONE: 400
1. Reason for the JobCDL 78-01
Thrust Reverser Opening Actuator
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 400 | POWER PLANT, NACELLES AND PYLONS |
| FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1) | |
| 437AL, 438AR | |
| FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2) | |
| 447AL, 448AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-00-010-803-A | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-803-A | Closing of the Fan Cowl Doors |
| TASK 78-30-00-040-807-A | Deactivation of the Thrust Reverser System for Nacelle Maintenance (ICU) |
| TASK 78-30-00-440-807-A | Reactivation of the Thrust Reverser System after Nacelle Maintenance (ICU) |
| TASK 78-36-51-000-802-A | Removal of the Thrust Reverser Cowl Opening System |
Subtask 78-36-00-941-081-A
A. Safety Precautions
(1) On the center pedestal, on ENG panel 115VU:
(a) Make sure that the ENG/MODE selector switch is in the NORM position.
(b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
(c) Put the WARNING NOTICE(S) in position to tell persons not to operate:
(a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put the WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
Subtask 78-36-00-010-142-A (1) On the center pedestal, on ENG panel 115VU:
(a) Make sure that the ENG/MODE selector switch is in the NORM position.
(b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
(c) Put the WARNING NOTICE(S) in position to tell persons not to operate:
- The ENG/MODE selector switch and
- The ENG/MASTER 1(2) control switch.
(a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put the WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
B. Get Access
(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-803):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL, 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL, 448AR.
(2) Put the ACCESS PLATFORM 2M (6 FT) in position.
Subtask 78-36-00-040-091-A (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-803):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL, 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL, 448AR.
(2) Put the ACCESS PLATFORM 2M (6 FT) in position.
C. Deactivation of the Thrust Reverser System for Nacelle Maintenance
4. ProcedureWARNING:
YOU MUST DEACTIVATE THE THRUST REVERSER BEFORE YOU DO WORK ON OR AROUND IT. IF YOU DO NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE AN INJURY AND/OR DAMAGE.
(1) Do the deactivation of the thrust reverser system for nacelle maintenance (Ref. AMM TASK 78-30-00-040-807). Subtask 78-36-00-040-092-A
A. Deactivation of the Thrust Reverser Cowl Opening System
(1) Remove the thrust reverser cowl opening system (Ref. AMM TASK 78-36-51-000-802).
5. Close-up(1) Remove the thrust reverser cowl opening system (Ref. AMM TASK 78-36-51-000-802).
Subtask 78-36-00-440-081-A
A. Do the reactivation of the thrust reverser system after nacelle maintenance (Ref. AMM TASK 78-30-00-440-807).
Subtask 78-36-00-410-129-A B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-803):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL, 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL, 448AR.
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
(5) Make an entry in the logbook to tell that you did the deactivation of the thrust reverser cowl opening system as per CDL 78-01.
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-803):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL, 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL, 448AR.
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
(5) Make an entry in the logbook to tell that you did the deactivation of the thrust reverser cowl opening system as per CDL 78-01.