W DOC AIRBUS | AMM A320F

Removal of the Thrust Reverser HCU Filter Cartridge [IAE]


TASK 78-31-51-000-011-A
Removal of the Thrust Reverser HCU Filter Cartridge


WARNING: DO NOT GET HYDRAULIC FLUID ON YOUR SKIN, IN YOUR EYES OR IN YOUR MOUTH. HYDRAULIC FLUID IS POISONOUS AND CAN GO THROUGH YOUR SKIN AND INTO YOUR BODY. FLUSH HYDRAULIC FLUID FROM YOUR EYES, MOUTH OR SKIN WITH WATER. GET MEDICAL AID IF YOU GET HYDRAULIC FLUID IN YOUR EYES OR MOUTH.
CAUTION: DO NOT LET HYDRAULIC FLUID FALL ON THE ENGINE. UNWANTED HYDRAULIC FLUID MUST BE REMOVED IMMEDIATELY WITH A CLEAN LINT FREE CLOTH. THE FLUID CAN CAUSE DAMAGE TO THE SURFACE PROTECTION AND TO SOME PARTS.
FIN: 4101KS1 ** ON A/C NOT FOR ALL
FIN: 4101KS2 ** ON A/C NOT FOR ALL
1. Reason for the Job
This task supplies the data to remove the thrust reverser Hydraulic Control Unit (HCU) filter cartridge and gain access to the clog indicator.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 2M (6 FT)
No specific
AR
CONTAINER 10 L(2 1/2 USGAL)
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [1000EM1] (ENGINE-1)
437AL, 438AR
FOR [1000EM2] (ENGINE-2)
447AL, 448AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 29-10-00-864-001-A
Depressurize the Green Hydraulic System
TASK 29-10-00-864-002-A
Depressurize the Yellow Hydraulic System
TASK 29-14-00-614-001-A
Depressurization of the Hydraulic Reservoirs
TASK 71-13-00-010-010-A
Opening of the Fan Cowls 437AL(447AL),438AR(448AR)
TASK 78-30-00-040-012-A
Deactivation of the Thrust Reverser Hydraulic Control Unit (HCU) for Ground Maintenance
3. Job Set-up
Subtask 78-31-51-864-051-A ** ON A/C NOT FOR ALL
A. Depressurization of hydraulic systems
   (1) Put a WARNING NOTICE(S) in position to tell persons not to pressurize the applicable system.
     (a) On the HYD/FUEL panel 40VU.
     (b) On the ground service panel of the applicable hydraulic system.
   (2) Depressurize the applicable hydraulic system (Ref. AMM TASK 29-10-00-864-001) or (Ref. AMM TASK 29-10-00-864-002).
   (3) Depressurize the reservoir of the applicable hydraulic system (Ref. AMM TASK 29-14-00-614-001).
Subtask 78-31-51-941-057-A ** ON A/C NOT FOR ALL
B. Safety Precautions
   (1) On the center pedestal, on the ENG panel 115VU:
     (a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
   (2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
   (3) On the overhead maintenance panel 50VU:
     (a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 78-31-51-010-061-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) Open the fan cowls (Ref. AMM TASK 71-13-00-010-010):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR.
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
   (2) Put the ACCESS PLATFORM 2M (6 FT) in position.
Subtask 78-31-51-040-057-A ** ON A/C NOT FOR ALL
D. Deactivate the thrust reverser
WARNING: MAKE SURE THAT THE THRUST REVERSER HYDRAULIC CONTROL UNIT (HCU) IS DEACTIVATED BEFORE YOU DO WORK ON OR AROUND THE THRUST REVERSER. IF THE HCU IS NOT DEACTIVATED, THERE IS A RISK OF UNWANTED THRUST REVERSER OPERATION WHICH CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
   (1) Deactivate the thrust reverser Hydraulic Control Unit (HCU) (Ref. AMM TASK 78-30-00-040-012).
4. Procedure
Subtask 78-31-51-020-052-A ** ON A/C NOT FOR ALL
A. Removal of the thrust reverser HCU filter module
   (1) Remove the HCU filter cartridge
     (a) Put a CONTAINER 10 L(2 1/2 USGAL) under the HCU to catch the hydraulic fluid from the connections when they are opened.
     (b) Remove the lockwire from the filter bowl (3).
     (c) Turn the filter bowl by hand in a counterclockwise direction and remove it from the HCU filter head (1).
     (d) Remove the filter cartridge (4) from the HCU filter head (1).
   (2) Remove the sight glass of the HCU filter clog indicator
     (a) Turn the retaining ring (6) in a counterclockwise direction and remove it from the HCU filter head (1).
     (b) Remove the sight glass (5).
[Rev.10 from 2021] 2026.04.01 03:27:41 UTC