W DOC AIRBUS | AMM A320F

Reactivation of the Thrust Reverser With Inhibition Cable Missing [PW11]


TASK 78-31-00-440-803-A
Reactivation of the Thrust Reverser With Inhibition Cable Missing


1. Reason for the Job
CDL 78-35
Hydraulic Control Unit Inhibition Handle
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TASK 78-30-00-440-806-A
Reactivation of the Thrust Reverser System for Flight
TASK 78-31-06-400-801-A
Installation of the Lower Inhibit Lever Cable
TASK 78-31-06-400-802-A
Installation of the Upper Inhibit Lever Cable
3. Job Set-up
Subtask 78-31-00-860-086-A ** ON A/C NOT FOR ALL
A. NOT APPLICABLE
4. Procedure
Subtask 78-31-00-400-053-A ** ON A/C NOT FOR ALL
A. Install the Lower inhibition lever cable (Ref. AMM TASK 78-31-06-400-801)
Subtask 78-31-00-400-054-A ** ON A/C NOT FOR ALL
B. Install the Upper inhibition lever cable (Ref. AMM TASK 78-31-06-400-802)
Subtask 78-31-00-440-058-A ** ON A/C NOT FOR ALL
C. Do the reactivation of the Thrust Reverser System for flight (Ref. AMM TASK 78-30-00-440-806)
[Rev.10 from 2021] 2026.04.01 03:30:55 UTC