Deactivation of the Thrust Reverser With Inhibition Cable Missing [PW11]
TASK 78-31-00-040-803-A
Deactivation of the Thrust Reverser With Inhibition Cable Missing
1. Reason for the Job
CDL 78-35
Hydraulic Control Unit Inhibition Handle
2. Job Set-up Information
A. Referenced Information
3. Job Set-up
Subtask 78-31-00-860-083-A ** ON A/C NOT FOR ALL
Subtask 78-31-00-000-052-A ** ON A/C NOT FOR ALL
Subtask 78-31-00-860-085-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 03:30:54 UTC
Deactivation of the Thrust Reverser With Inhibition Cable Missing
1. Reason for the Job
CDL 78-35
Hydraulic Control Unit Inhibition Handle
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TASK 78-30-00-040-806-A | Deactivation of the Thrust Reverser for Flight |
| TASK 78-31-06-000-801-A | Removal of the Lower Inhibit Lever Cable |
| TASK 78-31-06-000-802-A | Removal of the Upper Inhibit Lever Cable |
Subtask 78-31-00-860-083-A ** ON A/C NOT FOR ALL
A. Not Applicable
4. ProcedureSubtask 78-31-00-000-052-A ** ON A/C NOT FOR ALL
A. Make sure that the Lower inhibition lever cable is removed (Ref. AMM TASK 78-31-06-000-801)
Subtask 78-31-00-000-051-A ** ON A/C NOT FOR ALL Subtask 78-31-00-040-061-A ** ON A/C NOT FOR ALL NOTE: Make sure the applicable Hydraulic Control Unit Inhibition Handle is removed.
C. Deactivation of the Thrust Reverser System for Flight (Ref. AMM TASK 78-30-00-040-806)
5. Close-upNOTE: Maintenance deactivation procedure is not needed to be applied because inhibition lever cable has been already removed
Subtask 78-31-00-860-085-A ** ON A/C NOT FOR ALL
A. Make an applicable entry in the log book"