Visual Inspection of the Electronic Engine Control (EEC) Blower Fire Shield Blanket (PRE SB72-01-91) [CFML]
TASK 75-24-05-210-802-A
Visual Inspection of the Electronic Engine Control (EEC) Blower Fire Shield Blanket (PRE SB72-01-91)
This procedure gives the visual inspection criteria for the exhaust tube.
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 75-24-05-941-058-A
Subtask 75-24-05-210-051-A
Subtask 75-24-05-410-054-A
[Rev.10 from 2021]
2026.04.01 03:14:46 UTC
Visual Inspection of the Electronic Engine Control (EEC) Blower Fire Shield Blanket (PRE SB72-01-91)
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
ZONE: 400
1. Reason for the JobThis procedure gives the visual inspection criteria for the exhaust tube.
NOTE: If necessary, remove high metal with hand blending before visual inspection.
NOTE: You can use equivalent alternatives for standard tools, equipment and consumable materials.
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 400 | POWER PLANT, NACELLES AND PYLONS |
| FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1) | |
| 437AL, 438AR | |
| FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2) | |
| 447AL, 448AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-00-010-803-A | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-803-A | Closing of the Fan Cowl Doors |
| TASK 75-24-05-000-803-A | Removal of the EEC Blower Fire Shield Blanket (PRE SB72-0191) |
| TASK 75-24-05-400-803-A | Installation of the EEC Blower Fire Shield Blanket (PRE SB72-0191) |
Subtask 75-24-05-941-058-A
A. Safety Precautions
(1) On the center pedestal, on ENG panel 115VU:
(a) Make sure that the ENG/MODE selector switch is in the NORM position.
(b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
(c) Put WARNING NOTICE(S) in position to tell persons not to operate:
(a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
Subtask 75-24-05-010-058-A (1) On the center pedestal, on ENG panel 115VU:
(a) Make sure that the ENG/MODE selector switch is in the NORM position.
(b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
(c) Put WARNING NOTICE(S) in position to tell persons not to operate:
- The ENG/MODE selector switch
- The ENG/MASTER 1(2) control switch.
(a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
B. Get Access
(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-803):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
(2) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
(3) Remove the EEC blower fire shield blanket (Ref. AMM TASK 75-24-05-000-803).
4. Procedure(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-803):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
(2) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
(3) Remove the EEC blower fire shield blanket (Ref. AMM TASK 75-24-05-000-803).
Subtask 75-24-05-210-051-A
A. Visual Inspection of the Electronic Engine Control (EEC) Blower Fire Shield Blanket
(1) Table 601 - Visual inspection of all areas
(2) Table 602 - Visual inspection of the fasteners (2)
(3) Table 603 - Visual inspection of the decompression holes (3)
(4) Table 604 - Visual inspection of the external coating of inner envelope (4) and outer envelope (5)
5. Close-up(1) Table 601 - Visual inspection of all areas
| INSPECT/CHECK | MAXIMUM SERVICEABLE LIMITS | REMARKS |
|---|---|---|
| Tears, cuts | Not serviceable. | |
| INSPECT/CHECK | MAXIMUM SERVICEABLE LIMITS | REMARKS |
|---|---|---|
| Absence of adhesion | Not serviceable. | |
| INSPECT/CHECK | MAXIMUM SERVICEABLE LIMITS | REMARKS |
|---|---|---|
| Inner obstruction | Not serviceable. | |
| INSPECT/CHECK | MAXIMUM SERVICEABLE LIMITS | REMARKS |
|---|---|---|
| Scratches | Permitted if:
| |
| Tears | Permitted if:
| |
| Local soft abrasion | Permitted if:
| |
Subtask 75-24-05-410-054-A
A. Close Access
(1) Install the EEC blower fire shield blanket (Ref. AMM TASK 75-24-05-400-803).
(2) Make sure that the work area is clean and clear of tools and other items.
(3) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-803):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
(4) Remove the access platform(s).
(5) Remove the WARNING NOTICE(S).
(1) Install the EEC blower fire shield blanket (Ref. AMM TASK 75-24-05-400-803).
(2) Make sure that the work area is clean and clear of tools and other items.
(3) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-803):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
(4) Remove the access platform(s).
(5) Remove the WARNING NOTICE(S).
Visual Inspection of the Electronic Engine Control (EEC) Blower Fire Shield Blanket