W DOC AIRBUS | AMM A320F

Removal of the Fuel Filter Differential Pressure Sensor Damper [PW11]


TASK 73-34-21-000-802-A
Removal of the Fuel Filter Differential Pressure Sensor Damper


WARNING: BE CAREFUL WHEN YOU DO WORK ON THE ENGINE AFTER SHUTDOWN. THE ENGINE CAN STAY HOT FOR A LONG TIME. IF YOU DO NOT OBEY THIS INSTRUCTION, INJURY CAN OCCUR.
CAUTION: DO NOT LET ENGINE FUEL, OIL OR HYDRAULIC FLUID SPILL ON THE ENGINE. YOU MUST IMMEDIATELY REMOVE UNWANTED FUEL, OIL OR HYDRAULIC FLUID WITH A CLOTH. FUEL, OIL OR HYDRAULIC FLUID CAN CAUSE DAMAGE TO SOME ENGINE PARTS.
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
COVER - PROTECTION
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL, 438AR, 452AR
FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL, 448AR, 462AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 71-00-00-860-832-A
Procedure to Prevent Engine Motoring and to Stop the Electrical Supply to the EEC
TASK 71-13-00-010-802-A
Opening of the Fan Cowl Doors
TASK 78-30-00-040-805-A
Deactivation of the Thrust Reverser System for Ground Maintenance
TASK 78-36-00-010-802-A
Opening of the Thrust Reverser Cowl-Doors
3. Job Set-up
Subtask 73-34-21-941-052-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) Do the procedure to prevent engine motoring and to stop the electrical supply to the Electronic Engine Control (EEC)
(Ref. AMM TASK 71-00-00-860-832).
Subtask 73-34-21-010-054-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-802):
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL 438AR
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL 448AR
Subtask 73-34-21-040-052-A ** ON A/C NOT FOR ALL
C. Deactivation of the Thrust Reverser for Ground Maintenance
WARNING: YOU MUST DEACTIVATE THE THRUST REVERSER BEFORE YOU DO WORK ON OR AROUND IT. IF YOU DO NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE AN INJURY AND/OR DAMAGE.
   (1) Do the deactivation of the thrust reverser system for ground maintenance (Ref. AMM TASK 78-30-00-040-805).
Subtask 73-34-21-010-055-A ** ON A/C NOT FOR ALL
D. Get Access
   (1) Open the right thrust reverser cowl-doors (Ref. AMM TASK 78-36-00-010-802):
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
452AR
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
462AR
4. Procedure
CAUTION: WIPE CLEAN ALL PARTS AND TOOLS AS NECESSARY TO REMOVE UNWANTED DEBRIS AND PREVENT DAMAGE TO THE ENGINE.
Subtask 73-34-21-020-051-A ** ON A/C NOT FOR ALL
A. Removal of the Fuel Filter Differential Pressure Sensor Damper
   (1) Find the damper (1) attached to the fuel manifold housing at the 4 o'clock position.
   (2) Remove the damper (1) from the fuel manifold as follows:
     (a) Remove the two bolts (2) from the damper (1).
     (b) Remove the damper (1) from the fuel manifold.
     (c) Remove and discard the packings (3) and (4).
   (3) Installation of the protection covers.
CAUTION: INSTALL PROTECTION COVERS ON ALL THE OPENINGS IMMEDIATELY TO PREVENT DAMAGE TO THE ENGINE.
     (a) Make sure that you install COVER - PROTECTION as necessary to prevent damage to the engine.
[Rev.10 from 2021] 2026.04.01 03:03:43 UTC