Installation of the Fuel Tubes [CFMI]
TASK 73-11-49-400-040-A
Installation of the Fuel Tubes
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Expendable Parts
E. Referenced Information
3. Job Set-up
Subtask 73-11-49-860-050-A ** ON A/C NOT FOR ALL
Subtask 73-11-49-420-051-B ** ON A/C NOT FOR ALL
Subtask 73-11-49-410-053-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 02:55:41 UTC
Installation of the Fuel Tubes
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.CP2442) | engine oil |
| (Material No.CP8002) | lockwire 0.032 in. (0.8 mm) dia |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR | |
| FIG.ITEM | DESIGNATION | IPC-CSN |
|---|---|---|
| 60 | PACKINGS | AIPC 73-34-15-01-020 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 71-00-00-710-001-A | Dry Motoring Check |
| TASK 71-13-00-010-040-A | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-040-A | Closing of the Fan Cowl Doors |
Subtask 73-11-49-860-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) On the center pedestal, on the ENG panel 115VU, make sure that a WARNING NOTICE(S) is in position to tell persons not to start the engine.
(2) On the overhead maintenance panel 50VU, make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off. Make sure that a WARNING NOTICE(S) is in position to tell persons not to energize the FADEC 1(2).
(3) Make sure that the ACCESS PLATFORM 1M(3 FT) is in position.
(4) On the circuit breaker 1KC1(2), make sure that a WARNING NOTICE(S) is in position to tell persons not to open it (them).
Subtask 73-11-49-865-053-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on the ENG panel 115VU, make sure that a WARNING NOTICE(S) is in position to tell persons not to start the engine.
(2) On the overhead maintenance panel 50VU, make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off. Make sure that a WARNING NOTICE(S) is in position to tell persons not to energize the FADEC 1(2).
(3) Make sure that the ACCESS PLATFORM 1M(3 FT) is in position.
(4) On the circuit breaker 1KC1(2), make sure that a WARNING NOTICE(S) is in position to tell persons not to open it (them).
B. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 73-11-49-865-058-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 1000EM1 (ENGINE1) | |||
| 49VU | ENGINE/1/HP FUEL SOV | 1KC1 | A01 |
| FOR FIN: 1000EM2 (ENGINE2) | |||
| 49VU | ENGINE/2/HP FUEL SOV | 1KC2 | A02 |
C. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
Subtask 73-11-49-010-055-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 1000EM1 (ENGINE1) | |||
| 49VU | FUEL/LP VALVE/MOT1/ENG1 | 1QG | A08 |
| 121VU | FUEL/LP VALVE/MOT2/ENG1 | 3QG | M25 |
| FOR FIN: 1000EM2 (ENGINE2) | |||
| 49VU | FUEL/LP VALVE/MOT1/ENG2 | 2QG | A09 |
| 121VU | FUEL/LP VALVE/MOT2/ENG2 | 4QG | M26 |
D. Make sure that the fan cowl doors are open (Ref. AMM TASK 71-13-00-010-040):
(1) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(2) FOR [1000EM2] (ENGINE-2)
447AL 448AR
4. Procedure(1) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(2) FOR [1000EM2] (ENGINE-2)
447AL 448AR
Subtask 73-11-49-420-051-B ** ON A/C NOT FOR ALL
A. Installation of the Fuel Tubes
(1) Remove the protective covers from the switch (5) and the upper tubes (35) and (40). Install the upper tubes (35) and (40) to the fuel filter differential pressure switch (5). TORQUE the couplings to between 160 and 150 lbf.in (1.81 and 1.70 m.daN )
.
(2) Lubricate the AIPC 73-34-15-01-020 PACKINGS (60) with engine oil (Material No.CP2442) .
(3) Put the packings (60) on the unions (55).
(4) Install the unions (55) in the fuel filter (10).
.
(6) Remove the protective covers from the lower tubes (45) and (50). Install tube (45) on the low pressure port of fuel filter (10). Install tube (50) on the high pressure port of fuel filter (10). TORQUE the tube coupling nuts to between 150 and 135 lbf.in (1.70 and 1.53 m.daN )
.
Subtask 73-11-49-420-052-B ** ON A/C NOT FOR ALL (1) Remove the protective covers from the switch (5) and the upper tubes (35) and (40). Install the upper tubes (35) and (40) to the fuel filter differential pressure switch (5). TORQUE the couplings to between 160 and 150 lbf.in (1.81 and 1.70 m.daN )
. (2) Lubricate the AIPC 73-34-15-01-020 PACKINGS (60) with engine oil (Material No.CP2442) .
(3) Put the packings (60) on the unions (55).
(4) Install the unions (55) in the fuel filter (10).
NOTE: Make sure you install the unions (55) with the small orifice mating with the tubes.
(5) TORQUE the unions (55) to between 160 and 150 lbf.in (1.81 and 1.70 m.daN )
. (6) Remove the protective covers from the lower tubes (45) and (50). Install tube (45) on the low pressure port of fuel filter (10). Install tube (50) on the high pressure port of fuel filter (10). TORQUE the tube coupling nuts to between 150 and 135 lbf.in (1.70 and 1.53 m.daN )
. NOTE: Use a second wrench to hold the unions (55) when you torque the tube coupling nuts.
B. Connection of the Lower Tubes to the Upper Tubes
(1) Connect the lower tube (45) to the upper tube (35). Connect the lower tube (50) to the upper tube (40). TORQUE the tube coupling nuts to between 160 and 150 lbf.in (1.81 and 1.70 m.daN )
.
(2) Attach the tubes to the brackets and to each other with the clamps (15), the screws (20), the washers (30) and the nuts (25). TORQUE the nuts to between 25 and 20 lbf.in (0.28 and 0.23 m.daN )
.
Subtask 73-11-49-420-053-B ** ON A/C NOT FOR ALL (1) Connect the lower tube (45) to the upper tube (35). Connect the lower tube (50) to the upper tube (40). TORQUE the tube coupling nuts to between 160 and 150 lbf.in (1.81 and 1.70 m.daN )
. (2) Attach the tubes to the brackets and to each other with the clamps (15), the screws (20), the washers (30) and the nuts (25). TORQUE the nuts to between 25 and 20 lbf.in (0.28 and 0.23 m.daN )
. C. Install the insulation housing.
(1) Put the insulation housing (65) on the pressure switch.
(2) Wind theCP8002 lockwire 0.032 in. (0.8 mm) dia around the capstan. Route the lockwire between the fittings on the differential pressure switch (5).
Subtask 73-11-49-942-051-A ** ON A/C NOT FOR ALL (1) Put the insulation housing (65) on the pressure switch.
(2) Wind the
NOTE: Do not tighten the lockwire more than necessary to hold the insulation housing in position on the pressure switch.
D. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the access platform(s).
(3) Remove the WARNING NOTICE(S).
Subtask 73-11-49-865-055-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the access platform(s).
(3) Remove the WARNING NOTICE(S).
E. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 73-11-49-710-051-A ** ON A/C NOT FOR ALL 5. Close-up| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 1000EM1 (ENGINE1) | |||
| 49VU | FUEL/LP VALVE/MOT1/ENG1 | 1QG | A08 |
| 121VU | FUEL/LP VALVE/MOT2/ENG1 | 3QG | M25 |
| FOR FIN: 1000EM2 (ENGINE2) | |||
| 49VU | FUEL/LP VALVE/MOT1/ENG2 | 2QG | A09 |
| 121VU | FUEL/LP VALVE/MOT2/ENG2 | 4QG | M26 |
Subtask 73-11-49-410-053-A ** ON A/C NOT FOR ALL
A. Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
(1) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(2) FOR [1000EM2] (ENGINE-2)
447AL 448AR
Subtask 73-11-49-862-050-A ** ON A/C NOT FOR ALL (1) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(2) FOR [1000EM2] (ENGINE-2)
447AL 448AR
Fuel Tubes