W DOC AIRBUS | AMM A320F

Installation of the Fuel Manifold Gasket Seals [CFMI]


TASK 73-11-31-400-001-A
Installation of the Fuel Manifold Gasket Seals


FIN: 1000EM1 ** ON A/C NOT FOR ALL
FIN: 1000EM2 ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 1M(3 FT)
No specific
AR
WARNING NOTICE(S)
No specific
Torque wrench: range to between 110 and 100 lbf.in (1.24 and 1.13 m.daN ) T
No specific
Torque wrench: range to between 145 and 135 lbf.in (1.64 and 1.53 m.daN ) T
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [1000EM1] (ENGINE-1)
437AL, 438AR, 451AL, 452AR
FOR [1000EM2] (ENGINE-2)
447AL, 448AR, 461AL, 462AR
 C. Expendable Parts
FIG.ITEM
DESIGNATION
IPC-CSN
110
GASKET SEAL
AIPC 73-11-31-01-040
90
GASKET SEAL
AIPC 73-11-31-01-040
45
GASKET SEAL
AIPC 73-11-31-01-070
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 71-00-00-710-006-A
Minimum Idle Check
TASK 71-13-00-010-040-A
Opening of the Fan Cowl Doors
TASK 71-13-00-410-040-A
Closing of the Fan Cowl Doors
TASK 78-30-00-081-041-A
Make the Thrust Reverser Serviceable after Maintenance
TASK 78-30-00-481-041-A
Make the Thrust Reverser Unserviceable for Maintenance
TASK 78-36-00-010-040-A
Opening of the Thrust Reverser Doors
TASK 78-36-00-410-040-A
Closing of the Thrust Reverser Doors
3. Job Set-up
Subtask 73-11-31-860-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) On the center pedestal, on the ENG panel 115VU, make sure that a WARNING NOTICE(S) is in position to tell persons not to start the engine.
   (2) On the overhead maintenance panel 50VU, make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off. Make sure that a WARNING NOTICE(S) is in position to tell persons not to energize the FADEC 1(2).
   (3) Make sure that the ACCESS PLATFORM 1M(3 FT) is in position.
Subtask 73-11-31-010-052-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Make sure that the fan cowl doors are open (Ref. AMM TASK 71-13-00-010-040):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
   (2) Make sure that the thrust reverser doors are open (Ref. AMM TASK 78-36-00-010-040):
     (a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
     (b) FOR [1000EM2] (ENGINE-2)
461AL 462AR
Subtask 73-11-31-040-051-A ** ON A/C NOT FOR ALL
C. Make sure that the thrust reverser is unserviceable (Ref. AMM TASK 78-30-00-481-041).
4. Procedure
Subtask 73-11-31-420-050-A ** ON A/C NOT FOR ALL Subtask 73-11-31-410-050-A ** ON A/C NOT FOR ALL Subtask 73-11-31-440-050-A ** ON A/C NOT FOR ALL
C. Make the thrust reverser serviceable (Ref. AMM TASK 78-30-00-081-041).
Subtask 73-11-31-710-050-A ** ON A/C NOT FOR ALL
D. Do a minimum idle check (Ref. AMM TASK 71-00-00-710-006).
5. Close-up
Subtask 73-11-31-410-051-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
   (2) Remove the access platform(s).
   (3) Remove the WARNING NOTICE(S).
[Rev.10 from 2021] 2026.04.01 02:55:28 UTC