Inspection of Aft Acoustical Panels [CFMI]
TASK 72-23-00-280-008-A
Inspection of Aft Acoustical Panels
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 72-23-00-941-100-A ** ON A/C NOT FOR ALL
Subtask 72-23-00-350-063-A ** ON A/C NOT FOR ALL
Subtask 72-23-00-410-118-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 02:38:45 UTC
Inspection of Aft Acoustical Panels
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 1M(3 FT) |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR, 451AL, 452AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR, 461AL, 462AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-00-010-040-A | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-040-A | Closing of the Fan Cowl Doors |
| TASK 72-23-00-000-004-A | Removal of the Aft Acoustical Panels |
| TASK 72-23-00-300-026-A | Repair of Forward, Mid and Aft Acoustical Panels when Missing Cup |
| TASK 72-23-00-400-004-A | Installation of the Aft Acoustical Panels |
| TASK 72-23-00-400-045-A | Installation of the Acoustical Panels Attachment Screw Locking |
| TASK 78-30-00-081-041-A | Make the Thrust Reverser Serviceable after Maintenance |
| TASK 78-30-00-481-041-A | Make the Thrust Reverser Unserviceable for Maintenance |
| TASK 78-36-00-010-040-A | Opening of the Thrust Reverser Doors |
| TASK 78-36-00-410-040-A | Closing of the Thrust Reverser Doors |
Subtask 72-23-00-941-100-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 72-23-00-010-126-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
B. Get Access
(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(2) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(3) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(4) Put an ACCESS PLATFORM 1M(3 FT) in position.
Subtask 72-23-00-040-074-A ** ON A/C NOT FOR ALL Subtask 72-23-00-010-127-A ** ON A/C NOT FOR ALL (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(2) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(3) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(4) Put an ACCESS PLATFORM 1M(3 FT) in position.
D. Open the thrust reverser doors (Ref. AMM TASK 78-36-00-010-040):
(1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(2) FOR [1000EM2] (ENGINE-2)
461AL 462AR
4. Procedure(1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(2) FOR [1000EM2] (ENGINE-2)
461AL 462AR
Subtask 72-23-00-350-063-A ** ON A/C NOT FOR ALL
A. Inspection of Aft Acoustical Panels
5. Close-up| INSPECT/CHECK | MAXIMUM SERVICEABLE LIMITS | REMARKS |
|---|---|---|
| 1.Missing protective coating | No limit | |
| 2.Superficial cracks in Tedlar film | No limits in number | Do periodical checks of the acoustical panels for delamination |
| 3.Deep cracks from bolt holes | A maximum of 2 thrucracks with 0.6 in. (15.24 mm) max length starting from attachment holes | Do periodical checks of the acoustical panels for delamination |
| 4.Delamination | Not serviceable | Replace panel(s) (Ref. AMM TASK 72-23-00-000-004) and (Ref. AMM TASK 72-23-00-400-004) |
| 5.Nicks, dents or impingement mark | No limits in number | |
| 6.Distortion | No limit | |
| 7.Pierced cups caused by screw head | Not serviceable | Install the panel (Ref. AMM TASK 72-23-00-400-045) |
| 8.Unbounded cups | Not serviceable | Repair the panel (Ref. AMM TASK 72-23-00-300-026) and re-install the panel immediately (Ref. AMM TASK 72-23-00-400-004). |
Subtask 72-23-00-410-118-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust reverser doors (Ref. AMM TASK 78-36-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(b) FOR [1000EM2] (ENGINE-2)
461AL 462AR
Subtask 72-23-00-440-068-A ** ON A/C NOT FOR ALL Subtask 72-23-00-410-119-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust reverser doors (Ref. AMM TASK 78-36-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(b) FOR [1000EM2] (ENGINE-2)
461AL 462AR