Shorted Wire and Insulation Resistance Check-Power Plant Wire Harnesses Wires [CFMI]


TASK 71-50-00-280-041-A
Shorted Wire and Insulation Resistance Check-Power Plant Wire Harnesses Wires


1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 1M(3 FT)
No specific
AR
MEGOHMMETER - MODEL 1863
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [1000EM1] (ENGINE-1)
437AL, 438AR, 447AL, 448AR, 451AL, 452AR
FOR [1000EM2] (ENGINE-2)
447AL, 448AR, 461AL, 462AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 71-13-00-010-040-A
Opening of the Fan Cowl Doors
TASK 71-13-00-410-040-A
Closing of the Fan Cowl Doors
TASK 78-30-00-081-041-A
Make the Thrust Reverser Serviceable after Maintenance
TASK 78-30-00-481-041-A
Make the Thrust Reverser Unserviceable for Maintenance
TASK 78-36-00-010-040-A
Opening of the Thrust Reverser Doors
TASK 78-36-00-410-040-A
Closing of the Thrust Reverser Doors
ESPM 205000
3. Job Set-up
Subtask 71-50-00-941-058-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) On the center pedestal, on the ENG panel 115VU:
     (a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
   (2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
   (3) On the overhead maintenance panel 50VU:
     (a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 71-50-00-010-067-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
   (2) FOR [1000EM1] (ENGINE-1)
437AL 438AR
   (3) FOR [1000EM1] (ENGINE-1)
447AL 448AR
   (4) Put the ACCESS PLATFORM 1M(3 FT) in position.
Subtask 71-50-00-040-058-A ** ON A/C NOT FOR ALL
C. Make the thrust reverser unserviceable (Ref. AMM TASK 78-30-00-481-041).
Subtask 71-50-00-010-064-A ** ON A/C NOT FOR ALL
D. Open the thrust reverser doors (Ref. AMM TASK 78-36-00-010-040):
   (1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
   (2) FOR [1000EM2] (ENGINE-2)
461AL 462AR
4. Procedure
Subtask 71-50-00-280-053-A ** ON A/C NOT FOR ALL
A. Check on Unsatisfactory Wires
   (1) Do a shorted wire check on unsatisfactory wires using a MEGOHMMETER - MODEL 1863 or equivalent.
CAUTION: YOU MUST DISCONNECT ALL THE CONNECTORS WHICH HAVE A RELATION TO THE CIRCUITS THAT ARE BEING CHECKED. FAILURE TO DO THIS WILL CAUSE UNSATISFACTORY RESISTANCE INDICATIONS AND POSSIBLE DAMAGE TO THE CIRCUITS.
CAUTION: DO NOT CAUSE DAMAGE TO CONNECTOR PINS WHEN YOU DO CONTINUITY CHECKS. DAMAGED PINS CAN BECOME LOOSE AND CAN THUS INTERMITTENTLY PREVENT CORRECT CONTINUITY.
     (a) Disconnect the connectors at each end of the wire harness which contains the unsatisfactory wire.
     (b) Set the megohmmeter to the 100 VDC scale.
     (c) Connect the leads of the megohmmeter to each end of the wire and check the wires resistance.
     (d) The resistance must be infinity.
     (e) Defective circuits must be repaired ESPM 205000.
   (2) Do an insulation resistance check on unsatisfactory wires using a MEGOHMMETER - MODEL 1863 or equivalent.
     (a) Disconnect the connectors at each end of the wire harness which contains the unsatisfactory wire.
     (b) Set the megohmmeter to the 500 VDC scale.
     (c) Connect one test lead of the megohmmeter to the backshell body of the connector.
     (d) Connect the other lead to the contact (pin or contact of the connector) of the connector.
     (e) Measure the resistance. The resistance must be a minimum of 20 megohms.
5. Close-up
Subtask 71-50-00-410-067-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the thrust reverser doors (Ref. AMM TASK 78-36-00-410-040):
   (3) FOR [1000EM1] (ENGINE-1)
451AL 452AR
   (4) FOR [1000EM2] (ENGINE-2)
461AL 462AR
Subtask 71-50-00-440-058-A ** ON A/C NOT FOR ALL
B. Make the thrust reverser serviceable (Ref. AMM TASK 78-30-00-081-041).
Subtask 71-50-00-410-064-A ** ON A/C NOT FOR ALL
C. Close Access
   (1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
   (2) FOR [1000EM1] (ENGINE-1)
437AL 438AR
   (3) FOR [1000EM2] (ENGINE-2)
447AL 448AR
   (4) Remove the access platform(s).
   (5) Remove the WARNING NOTICE(S).