Detailed Inspection of the Bores of the Elevator Actuator Attach-Fittings and Hinge Fittings, LH/RH
TASK 55-26-00-220-801-A
Detailed Inspection of the Bores of the Elevator Actuator Attach-Fittings and Hinge Fittings, LH/RH
Refer to the MPD TASK: 552601-01
DETAILED INSPECTION OF THE BORES OF THE ELEVATOR ACTUATOR ATTACH-FITTINGS AND HINGE FITTINGS, LH/RH
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 55-26-00-941-051-A ** ON A/C NOT FOR ALL
Subtask 55-26-00-220-060-A ** ON A/C NOT FOR ALL
Subtask 55-26-00-420-050-A ** ON A/C NOT FOR ALL Subtask 55-26-00-410-054-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 02:05:40 UTC
Detailed Inspection of the Bores of the Elevator Actuator Attach-Fittings and Hinge Fittings, LH/RH
WARNING:
MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS SURFACES ARE CLEAR. MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
CAUTION:
BEFORE YOU INSTALL/REMOVE THE GSE-TOOL, READ THE INSTRUCTIONS IN THE APPLICABLE GSE INSTRUCTION MANUAL. WHILE YOU OPERATE THIS TOOL, CAREFULLY OBEY THEM. IF YOU DO NOT OBEY THE INSTRUCTIONS, DAMAGE TO EQUIPMENT CAN OCCUR.
1. Reason for the JobRefer to the MPD TASK: 552601-01
DETAILED INSPECTION OF THE BORES OF THE ELEVATOR ACTUATOR ATTACH-FITTINGS AND HINGE FITTINGS, LH/RH
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE |
| No specific | 1 | WARNING NOTICE(S) |
| 98D27903500000 | 2 | PIN-SIDE STICK LOCKING |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.08BAA9) | Non Aqueous Cleaner-General - - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 335 | ELEVATOR |
| 345 | ELEVATOR |
| 334BB, 334DB, 334FB, 334HB, 344BB, 344DB, 344FB, 344HB |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 27-34-41-000-001-A | Removal of the Elevator |
| TASK 27-34-41-400-001-A | Installation of the Elevator |
| TASK 55-13-11-000-001-A | Remove/Open of the Trimmable Horizontal Stabilizer (THS) Trailing-Edge Access-Panels |
| TASK 55-13-11-400-001-A | Install/Close of the Trimmable Horizontal Stabilizer (THS) Trailing-Edge Access-Panels |
| SRM 552641 | (for corrective action) |
| SRM 552647 | (for corrective action) |
Subtask 55-26-00-941-051-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) Put the 98D27903500000 PIN-SIDE STICK LOCKING in the CAPT and F/O side stick controllers.
(2) Put a WARNING NOTICE(S) in the flight compartment to tell persons not to operate the flight controls.
(3) Put a WARNING NOTICE(S) in position to tell persons not to operate the hydraulic systems.
Subtask 55-26-00-010-054-A ** ON A/C NOT FOR ALL (1) Put the 98D27903500000 PIN-SIDE STICK LOCKING in the CAPT and F/O side stick controllers.
(2) Put a WARNING NOTICE(S) in the flight compartment to tell persons not to operate the flight controls.
(3) Put a WARNING NOTICE(S) in position to tell persons not to operate the hydraulic systems.
B. Get Access
(1) Put an ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position:
(a) For the left elevator, in zone 335
(b) For the right elevator, in zone 345.
(2) Remove the THS trailing-edge access panels (Ref. AMM TASK 55-13-11-000-001):
(a) For the left elevator: 334BB 334DB 334FB 334HB
(b) For the right elevator: 344BB 344DB 344FB 344HB.
Subtask 55-26-00-020-050-A ** ON A/C NOT FOR ALL Subtask 55-26-00-110-050-A ** ON A/C NOT FOR ALL (1) Put an ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position:
(a) For the left elevator, in zone 335
(b) For the right elevator, in zone 345.
(2) Remove the THS trailing-edge access panels (Ref. AMM TASK 55-13-11-000-001):
(a) For the left elevator: 334BB 334DB 334FB 334HB
(b) For the right elevator: 344BB 344DB 344FB 344HB.
D. Cleaning
(1) Clean the inspection area with Non Aqueous Cleaner-General - - (Material No.08BAA9) and Textile-Lint free Cotton - (Material No.14SBA1) , if necessary.
4. Procedure(1) Clean the inspection area with Non Aqueous Cleaner-General - - (Material No.08BAA9) and Textile-Lint free Cotton - (Material No.14SBA1) , if necessary.
Subtask 55-26-00-220-060-A ** ON A/C NOT FOR ALL
A. Inspection
(1) Do a detailed inspection of the bores of the elevator actuator attach-fittings and hinge attach fittings. This inspection is applicable for left and right sides.
(2) Make sure that there is no:
(a) Corrosion damage:
If you find corrosion damage, refer to Structural Repair Manual SRM 552647 and SRM 552641 for the corrosion types, inspection, removal and subsequent corrosion protection.
(b) Other damage (scratches, cracks, gouges, dents, creases):
If you find this type of damage, refer to Structural Repair Manual SRM 552647 and SRM 552641 for the damage types, classification and corrective action.
5. Close-up(1) Do a detailed inspection of the bores of the elevator actuator attach-fittings and hinge attach fittings. This inspection is applicable for left and right sides.
(2) Make sure that there is no:
(a) Corrosion damage:
If you find corrosion damage, refer to Structural Repair Manual SRM 552647 and SRM 552641 for the corrosion types, inspection, removal and subsequent corrosion protection.
(b) Other damage (scratches, cracks, gouges, dents, creases):
If you find this type of damage, refer to Structural Repair Manual SRM 552647 and SRM 552641 for the damage types, classification and corrective action.
Subtask 55-26-00-420-050-A ** ON A/C NOT FOR ALL Subtask 55-26-00-410-054-A ** ON A/C NOT FOR ALL
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the THS trailing-edge access panels (Ref. AMM TASK 55-13-11-400-001):
(a) For the left elevator: 334BB 334DB 334FB 334HB
(b) For the right elevator: 344BB 344DB 344FB 344HB.
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
(5) Remove the 98D27903500000 PIN-SIDE STICK LOCKING from the CAPT and F/O side stick controllers.
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the THS trailing-edge access panels (Ref. AMM TASK 55-13-11-400-001):
(a) For the left elevator: 334BB 334DB 334FB 334HB
(b) For the right elevator: 344BB 344DB 344FB 344HB.
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
(5) Remove the 98D27903500000 PIN-SIDE STICK LOCKING from the CAPT and F/O side stick controllers.
Elevator Actuator Attach-Fittings and Hinge Fittings, Left and Right Sides