Removal of the Nose Fire Seal
TASK 54-57-22-000-811-A
Removal of the Nose Fire Seal
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 54-57-22-941-077-A ** ON A/C NOT FOR ALL
Subtask 54-57-22-020-069-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2017]
2026.04.01 02:04:18 UTC
Removal of the Nose Fire Seal
WARNING:
YOU MUST BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE IS SHUTDOWN. THE ENGINE PARTS CAN STAY HOT FOR ALMOST 1 HOUR.
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
1. Reason for the Job- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 410 | ENG 1 PYLON BOX AND FORWARD FAIRING |
| 420 | ENG 2 PYLON BOX AND FORWARD FAIRING |
| FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1) | |
| 437AL, 438AR, 451AL, 452AR | |
| FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2) | |
| 447AL, 448AR, 461AL, 462AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-00-00-860-833-A | Procedure to Prevent Engine Motoring |
| TASK 71-13-00-010-802-A | Opening of the Fan Cowl Doors |
| TASK 72-21-04-000-801-A | Removal of the Fan Exit Fairing - Upper Bifi |
| TASK 78-30-00-040-805-A | Deactivation of the Thrust Reverser System for Ground Maintenance |
| TASK 78-36-00-010-802-A | Opening of the Thrust Reverser Cowl-Doors |
Subtask 54-57-22-941-077-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) Do the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833).
Subtask 54-57-22-040-065-A ** ON A/C NOT FOR ALL (1) Do the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833).
B. Deactivation of the Thrust Reverser
Subtask 54-57-22-010-065-A ** ON A/C NOT FOR ALL WARNING:
MAKE SURE THAT THE THRUST REVERSER IS LOCKED. IF NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO THE REVERSER.
(1) Make the thrust reverser unserviceable for maintenance (Ref. AMM TASK 78-30-00-040-805). C. Get Access
(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
(2) Open the thrust reverser cowl-doors (Ref. AMM TASK 78-36-00-010-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
(3) Remove the fan exit fairing - upper Bifi (Ref. AMM TASK 72-21-04-000-801).
(4) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position:
(a) For the left pylon, at zone 410
(b) For the right pylon, at zone 420.
4. Procedure(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
(2) Open the thrust reverser cowl-doors (Ref. AMM TASK 78-36-00-010-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
(3) Remove the fan exit fairing - upper Bifi (Ref. AMM TASK 72-21-04-000-801).
(4) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position:
(a) For the left pylon, at zone 410
(b) For the right pylon, at zone 420.
Subtask 54-57-22-020-069-A ** ON A/C NOT FOR ALL
A. Removal of the Nose Fire Seal
(1) Remove the nuts (2) and the washers (1).
(2) Remove the nut (3).
(3) Remove the nose fire seal (4).
(1) Remove the nuts (2) and the washers (1).
(2) Remove the nut (3).
(3) Remove the nose fire seal (4).
Nose Fire Seal