Installation of the Thrust Reverser Cowl Fitting at RIB 1 and RIB 2
TASK 54-57-17-400-003-A
Installation of the Thrust Reverser Cowl Fitting at RIB 1 and RIB 2
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Expendable Parts
E. Referenced Information
3. Job Set-up
Subtask 54-57-17-860-052-A ** ON A/C NOT FOR ALL
Subtask 54-57-17-420-053-A ** ON A/C NOT FOR ALL
Subtask 54-57-17-420-054-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 02:03:46 UTC
Installation of the Thrust Reverser Cowl Fitting at RIB 1 and RIB 2
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | WARNING NOTICE(S) |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.06LDG2) | Non Hardening Jointing Putty-High Temp. Area - Structure |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 410 | ENG 1 PYLON BOX AND FORWARD FAIRING |
| 420 | ENG 2 PYLON BOX AND FORWARD FAIRING |
| 415AL, 415AR, 425AL, 425AR |
| FIG.ITEM | DESIGNATION | IPC-CSN |
|---|---|---|
| 10 | NUT | AIPC 54-51-17-02-020 |
| 8 | NUT | AIPC 54-57-17-02-010 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 54-51-21-400-001-A | Installation of the Pylon Lateral Access-Doors |
| TASK 78-32-11-400-002-A | Installation of the Left or Right Half Door of Thrust Reverser |
| TASK 78-32-11-400-040-A | Installation of the Left or Right Half Door of Thrust Reverser |
Subtask 54-57-17-860-052-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Make sure that the access platform and the WARNING NOTICE(S) are in position.
4. Procedure(1) Make sure that the access platform and the WARNING NOTICE(S) are in position.
Subtask 54-57-17-420-053-A ** ON A/C NOT FOR ALL
A. Installation of the Fitting at RIB1 and RIB2
(2) Obey the location and thickness of the peel washers (9) recorded at the removal.
(3) Put the shim (5) in the correct position on the pylon structure (6).
(4) Put the thrust reverser cowl fitting (2) in position.
(5) Install the washers (4) on the bolts (3).
(6) Install the bolts (3) with Non Hardening Jointing Putty-High Temp. Area - Structure (Material No.06LDG2) .
(7) Install the washers (7), the AIPC 54-57-17-02-010 NUT (8) and the AIPC 54-51-17-02-020 NUT (10).
(8) Tighten the nuts (8) and (10).
5. Close-upNOTE: The installation at Rib1 is the same as for Rib2.
(1) If you install new reverser fittings, do a dimensional check of the new and the used reverser fittings. (2) Obey the location and thickness of the peel washers (9) recorded at the removal.
(3) Put the shim (5) in the correct position on the pylon structure (6).
(4) Put the thrust reverser cowl fitting (2) in position.
(5) Install the washers (4) on the bolts (3).
(6) Install the bolts (3) with Non Hardening Jointing Putty-High Temp. Area - Structure (Material No.06LDG2) .
(7) Install the washers (7), the AIPC 54-57-17-02-010 NUT (8) and the AIPC 54-51-17-02-020 NUT (10).
(8) Tighten the nuts (8) and (10).
Subtask 54-57-17-420-054-A ** ON A/C NOT FOR ALL
A. Installation of Components
(1) Install the thrust reverser half doors (Ref. AMM TASK 78-32-11-400-040), (Ref. AMM TASK 78-32-11-400-002).
Subtask 54-57-17-410-052-A ** ON A/C NOT FOR ALL (1) Install the thrust reverser half doors (Ref. AMM TASK 78-32-11-400-040), (Ref. AMM TASK 78-32-11-400-002).
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the lateral access-doors (Ref. AMM TASK 54-51-21-400-001):
(a) for the left pylon: 415AL 415AR
(b) for the right pylon: 425AL 425AR.
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the lateral access-doors (Ref. AMM TASK 54-51-21-400-001):
(a) for the left pylon: 415AL 415AR
(b) for the right pylon: 425AL 425AR.
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
Thrust Reverser Cowl Fitting at RIB 1 and RIB 2