W DOC AIRBUS | AMM A320F

Reactivation of the Pressure Relief Doors


TASK 54-52-00-440-001-A
Reactivation of the Pressure Relief Doors


WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
  • THE FLIGHT CONTROLS
  • THE FLIGHT CONTROL SURFACES
  • THE LANDING GEAR AND THE RELATED DOORS
  • COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE EQUIPMENT.
ZONE: 410
ZONE: 420
FIN: 1000EM1 ** ON A/C NOT FOR ALL
FIN: 1000EM2 ** ON A/C NOT FOR ALL
1. Reason for the Job
CDL 54-03
Pylon Pressure Relief Door 413(423) BL - 414(424) BR
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
410
ENG 1 PYLON BOX AND FORWARD FAIRING
420
ENG 2 PYLON BOX AND FORWARD FAIRING
413CL, 423CL
413DL, 414CR, 423DL, 424CR
413CR, 413DT, 423CR, 423DT
 C. Expendable Parts
FIG.ITEM
DESIGNATION
IPC-CSN
9
COTTER PINS
AIPC 54-52-11-02-060
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 78-30-00-040-012-A
Deactivation of the Thrust Reverser Hydraulic Control Unit (HCU) for Ground Maintenance
TASK 78-30-00-081-041-A
Make the Thrust Reverser Serviceable after Maintenance
TASK 78-30-00-081-041-B
Make the Thrust Reverser Serviceable after Maintenance
TASK 78-30-00-440-012-A
Re-activation of the Thrust Reverser Hydraulic Control Unit (HCU) after Ground Maintenance
TASK 78-30-00-481-041-A
Make the Thrust Reverser Unserviceable for Maintenance
TASK 78-30-00-481-041-B
Make the Thrust Reverser Unserviceable for Maintenance
F Pressure Relief Doors ** ON A/C NOT FOR ALL
F Pressure Relief Doors ** ON A/C NOT FOR ALL
F Pressure Relief Doors ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 54-52-00-860-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Make sure that the access platform is in position.
   (2) Make sure that the WARNING NOTICE(S) is(are) in position.
   (3) Make sure that the thrust reversers are unserviceable (Ref. AMM TASK 78-30-00-481-041).
   (4) Make sure that the access panels are removed:
     (a) For the left pylon: 413DL, 413CL and 414CR
     (b) For the right pylon: 423DL, 423CL and 424CR.
Subtask 54-52-00-860-050-D ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Make sure that the access platform is in position.
   (2) Make sure that the WARNING NOTICE(S) is(are) in position.
   (3) Make sure that the thrust reversers are unserviceable (Ref. AMM TASK 78-30-00-481-041).
   (4) Make sure that the access panels are removed:
     (a) For the left pylon: 413CL, 413DT and 413CR
     (b) For the right pylon: 423CL, 423DT and 423CR.
Subtask 54-52-00-860-050-E ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Make sure that the access platform is in position.
   (2) Make sure that the WARNING NOTICE(S) is(are) in position.
   (3) Make sure that the thrust reversers are unserviceable (Ref. AMM TASK 78-30-00-040-012).
   (4) Make sure that the access panels are removed:
     (a) For the left pylon: 413CL, 413DT and 413CR
     (b) For the right pylon: 423CL, 423DT and 423CR.
4. Procedure
Subtask 54-52-00-440-052-A ** ON A/C NOT FOR ALL
A. Reactivation of the Pressure Relief Doors
F Pressure Relief Doors ** ON A/C NOT FOR ALL
F Pressure Relief Doors ** ON A/C NOT FOR ALL
F Pressure Relief Doors ** ON A/C NOT FOR ALL
NOTE: The reactivation of each pressure relief door is symmetrical.
   (1) Install the pressure relief door (1) or (2).
   (2) Install the shims (20) and (19).
   (3) Install the washers (18) and (16), the bolt (17) and the nut (21). Tighten the nut.
   (4) Install the shims (4), (3), (15) and (14).
   (5) Install the washer (13), the bolt (12) and the nut (5). Tighten the nut.
   (6) Install the shims (8) and (7), the pin (10) and the washers (6).
   (7) Install new AIPC 54-52-11-02-060 COTTER PINS (9) and safety them.
   (8) Install the spring (11).
Subtask 54-52-00-210-051-A ** ON A/C NOT FOR ALL
B. Test
   (1) Open and close the pressure relief doors to make sure that they are installed correctly.
5. Close-up
Subtask 54-52-00-410-051-A ** ON A/C NOT FOR ALL
Subtask 54-52-00-410-051-C ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Install the access panels:
     (a) For the left pylon: 413CL 413DT and 413CR
     (b) For the right pylon: 423CL 423DT and 423CR.
   (3) Remove the access platform(s).
   (4) Remove the WARNING NOTICE(S).
Subtask 54-52-00-410-051-D ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Install the access panels:
     (a) For the left pylon: 413CL 413DT and 413CR
     (b) For the right pylon: 423CL 423DT and 423CR.
   (3) Remove the access platform(s).
   (4) Remove the WARNING NOTICE(S).
Subtask 54-52-00-040-054-A ** ON A/C NOT FOR ALL
B. Aircraft Maintenance Configuration
   (1) Make the thrust reverser serviceable (Ref. AMM TASK 78-30-00-081-041).
Subtask 54-52-00-040-054-C ** ON A/C NOT FOR ALL
B. Aircraft Maintenance Configuration
   (1) Make the thrust reverser serviceable (Ref. AMM TASK 78-30-00-440-012).
[Rev.10 from 2021] 2026.04.01 02:01:47 UTC