Detailed Inspection of Pylon to Wing Forward Attachments, LH/RH
TASK 54-51-00-220-818-A
Detailed Inspection of Pylon to Wing Forward Attachments, LH/RH
Refer to the MPD TASK: 545318-01
DETAILED INSPECTION OF PYLON TO WING FORWARD ATTACHMENTS, LH/RH.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 54-51-00-941-113-A
Subtask 54-51-00-220-103-A
Subtask 54-51-00-410-126-A
[Rev.10 from 2021]
2026.04.01 02:00:14 UTC
Detailed Inspection of Pylon to Wing Forward Attachments, LH/RH
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE AFTER SHUTDOWN. THE ENGINE CAN STAY HOT FOR A LONG TIME. IF YOU DO NOT OBEY THIS INSTRUCTION, INJURY CAN OCCUR.
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
CAUTION:
DO NOT APPLY TEMPORARY PROTECTION SYSTEM (TPS) ON THE INSPECTION AREA. IF YOU APPLY TPS ON THE INSPECTION AREA, YOU CAN CAUSE DAMAGE TO THE AIRCRAFT.
1. Reason for the JobRefer to the MPD TASK: 545318-01
DETAILED INSPECTION OF PYLON TO WING FORWARD ATTACHMENTS, LH/RH.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| No specific | AR | WARNING NOTICE(S) |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.08BAA9) | Non Aqueous Cleaner-General - - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 410 | ENG 1 PYLON BOX AND FORWARD FAIRING |
| 420 | ENG 2 PYLON BOX AND FORWARD FAIRING |
| 470 | ENGINE 1 AFT PYLON |
| 480 | ENGINE 2 AFT PYLON |
| 413ET, 423ET, 471AL, 472AR, 481AL, 482AR |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 51-78-00-916-001-A | Application of Temporary Protection System (TPS) |
| TASK 54-53-11-000-806-A | Removal of the Pylon-to-Wing Access Panels and Doors |
| TASK 54-53-11-400-806-A | Installation of the Pylon-to-Wing Access Panels and Doors |
| TASK 78-30-00-040-809-A | Deactivation of the Thrust Reverser System for Ground Maintenance |
| TASK 78-30-00-440-809-A | Reactivation of the Thrust Reverser System after Ground Maintenance |
| SRM 511100 | (for corrective action) |
| SRM 512200 | (for corrective action) |
Subtask 54-51-00-941-113-A
A. Safety Precautions
(1) On the center pedestal, on ENG panel 115VU:
(a) Make sure that the ENG/MODE selector switch is in the NORM position.
(b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
(c) Put a WARNING NOTICE(S) in position to tell persons not to operate the ENG/MODE selector switch and the ENG/MASTER 1(2) control switch.
(2) On the ENG section of maintenance panel 50VU:
(a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
Subtask 54-51-00-040-109-A (1) On the center pedestal, on ENG panel 115VU:
(a) Make sure that the ENG/MODE selector switch is in the NORM position.
(b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
(c) Put a WARNING NOTICE(S) in position to tell persons not to operate the ENG/MODE selector switch and the ENG/MASTER 1(2) control switch.
(2) On the ENG section of maintenance panel 50VU:
(a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
B. Deactivation of the Thrust Reverser
Subtask 54-51-00-010-118-A WARNING:
MAKE SURE THAT THE THRUST REVERSER IS LOCKED. IF NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO THE REVERSER.
(1) Make the thrust reverser unserviceable for maintenance (Ref. AMM TASK 78-30-00-040-809). C. Get Access
(1) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position:
(a) For the left pylon, in zones 410 and 470
(b) For the right pylon, in zones 420 and 480.
(2) Remove the pylon-to-wing access panels (Ref. AMM TASK 54-53-11-000-806):
(a) For the left pylon: 413ET 471AL, 472AR
(b) For the right pylon: 423ET 481AL, 482AR.
Subtask 54-51-00-110-111-A (1) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position:
(a) For the left pylon, in zones 410 and 470
(b) For the right pylon, in zones 420 and 480.
(2) Remove the pylon-to-wing access panels (Ref. AMM TASK 54-53-11-000-806):
(a) For the left pylon: 413ET 471AL, 472AR
(b) For the right pylon: 423ET 481AL, 482AR.
D. Preparation of the Inspection Area
(1) Make sure that the inspection area is sufficiently clean to do a satisfactory inspection of the area.
(2) If it is not sufficiently clean, clean the inspection area with Non Aqueous Cleaner-General - - (Material No.08BAA9) and Textile-Lint free Cotton - (Material No.14SBA1) .
(3) Make sure that there is no Temporary Protection System (TPS) layer and if there is a TPS layer, remove it (Ref. AMM TASK 51-78-00-916-001).
4. Procedure(1) Make sure that the inspection area is sufficiently clean to do a satisfactory inspection of the area.
(2) If it is not sufficiently clean, clean the inspection area with Non Aqueous Cleaner-General - - (Material No.08BAA9) and Textile-Lint free Cotton - (Material No.14SBA1) .
(3) Make sure that there is no Temporary Protection System (TPS) layer and if there is a TPS layer, remove it (Ref. AMM TASK 51-78-00-916-001).
Subtask 54-51-00-220-103-A
A. Inspection
(1) Do a detailed inspection of the pylon-to-wing forward attachments. Do this inspection on the left and right sides.
(2) Make sure that there is no:
(a) Corrosion damage:
5. Close-up(1) Do a detailed inspection of the pylon-to-wing forward attachments. Do this inspection on the left and right sides.
(2) Make sure that there is no:
(a) Corrosion damage:
- If you find corrosion damage, refer to Structural Repair Manual SRM 512200 for types of corrosion, inspection, removal and corrosion protection.
- If you find this type of damage, refer to Structural Repair Manual SRM 511100 for damage classification and corrective action.
Subtask 54-51-00-410-126-A
A. Close Access
(1) Install the pylon-to-wing access panels (Ref. AMM TASK 54-53-11-400-806):
(a) For the left pylon: 413ET 471AL, 472AR
(b) For the right pylon: 423ET 481AL, 482AR.
Subtask 54-51-00-440-108-A (1) Install the pylon-to-wing access panels (Ref. AMM TASK 54-53-11-400-806):
(a) For the left pylon: 413ET 471AL, 472AR
(b) For the right pylon: 423ET 481AL, 482AR.
B. Reactivation of the Thrust Reverser
(1) Make the thrust reverser serviceable after maintenance (Ref. AMM TASK 78-30-00-440-809).
Subtask 54-51-00-942-083-A (1) Make the thrust reverser serviceable after maintenance (Ref. AMM TASK 78-30-00-440-809).
C. Aircraft Maintenance Configuration
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the access platform(s).
(3) Remove the WARNING NOTICE(S).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the access platform(s).
(3) Remove the WARNING NOTICE(S).
Pylon-to-Wing Forward Attachments